메뉴 건너뛰기




Volumn , Issue , 2010, Pages 320-323

Automatic active appearance model segmentation of 3D echocardiograms

Author keywords

3D echocardiography; Active Appearance Models; Automatic segmentation; Left ventricular volume; Ultrasound

Indexed keywords

3D ECHOCARDIOGRAPHY; ACTIVE APPEARANCE MODELS; AUTOMATED SEGMENTATION; AUTOMATIC SEGMENTATIONS; DATA SETS; FULLY OPERATIONAL; LEFT VENTRICULAR; MATCHING ALGORITHM;

EID: 77955221253     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISBI.2010.5490344     Document Type: Conference Paper
Times cited : (25)

References (11)
  • 1
    • 17144461250 scopus 로고    scopus 로고
    • High-resolution transthoracic real-time three-dimensional echocardiography: Quantitation of cardiac volumes and function using semi-automatic border detection and comparison with cardiac magnetic resonance imaging
    • H.P. Kühl, M. Schreckenberg, et al. "High-resolution transthoracic real-time three-dimensional echocardiography: Quantitation of cardiac volumes and function using semi-automatic border detection and comparison with cardiac magnetic resonance imaging". J Am Coll Cardiol, vol. 43, p. 2083-2090, 2004.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 2083-2090
    • Kühl, H.P.1    Schreckenberg, M.2
  • 2
    • 0036770476 scopus 로고    scopus 로고
    • Efficient model-based quantification of left ventricular function in 3D echocardiography
    • O. Gérard, A.C. Billon, et al. "Efficient model-based quantification of left ventricular function in 3D echocardiography". IEEE Trans Med Imaging, vol. 21, p. 1059-1068, 2002.
    • (2002) IEEE Trans Med Imaging , vol.21 , pp. 1059-1068
    • Gérard, O.1    Billon, A.C.2
  • 3
    • 65549090143 scopus 로고    scopus 로고
    • Semi-automated quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography
    • J. Hansegård, S. Urheim, et al. "Semi-automated quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography". Cardiovasc Ultrasound, vol. 7, p. 18, 2009.
    • (2009) Cardiovasc Ultrasound , vol.7 , pp. 18
    • Hansegård, J.1    Urheim, S.2
  • 4
    • 51949103386 scopus 로고    scopus 로고
    • Real-time 3D segmentation of the left ventricle using deformable subdivision surfaces
    • F. Orderud, S.I. Rabben. "Real-time 3D Segmentation of the Left Ventricle Using Deformable Subdivision Surfaces". In: Proc IEEE Computer Vision Pattern Recognition 2008, p. 1-8.
    • (2008) Proc IEEE Computer Vision Pattern Recognition , pp. 1-8
    • Orderud, F.1    Rabben, S.I.2
  • 6
    • 0037516834 scopus 로고    scopus 로고
    • 3-D active appearance models: Segmentation of cardiac MR and ultrasound images
    • S.C. Mitchell, J.G. Bosch, et al. "3-D Active Appearance Models: Segmentation of Cardiac MR and Ultrasound Images". IEEE Trans Med Imag, vol. 21, p. 1167-1178, 2002.
    • (2002) IEEE Trans Med Imag , vol.21 , pp. 1167-1178
    • Mitchell, S.C.1    Bosch, J.G.2
  • 7
    • 48149111304 scopus 로고    scopus 로고
    • Automatic segmentation of the left ventricle in 3D echocardiography using active appearance models
    • M. van Stralen, K.Y.E. Leung, et al. "Automatic segmentation of the left ventricle in 3D echocardiography using active appearance models". In IEEE Ultrasonics Symp 2007, p. 1480-1483.
    • (2007) IEEE Ultrasonics Symp , pp. 1480-1483
    • Van Stralen, M.1    Leung, K.Y.E.2
  • 8
    • 43449096364 scopus 로고    scopus 로고
    • Improving 3D active appearance model segmentation of the left ventricle with jacobian tuning
    • paper 69143B
    • K.Y.E. Leung, M. van Stralen, et al. "Improving 3D Active Appearance Model segmentation of the left ventricle with jacobian tuning". In Proc SPIE Medical Imaging 2008 vol. 6914, paper 69143B, p. 1-11.
    • (2008) Proc SPIE Medical Imaging , vol.6914 , pp. 1-11
    • Leung, K.Y.E.1    Van Stralen, M.2
  • 9
    • 84898025283 scopus 로고    scopus 로고
    • An algorithm for tuning an active appearance model to new data
    • T.F. Cootes and C.J. Taylor. "An Algorithm for Tuning an Active Appearance Model to New Data". In Proc British Machine Vision Conference 2006, p. 919-928.
    • (2006) Proc British Machine Vision Conference , pp. 919-928
    • Cootes, T.F.1    Taylor, C.J.2
  • 10
    • 0036879771 scopus 로고    scopus 로고
    • Automatic segmentation of echocardiographic sequences by active appearance motion models
    • J.G. Bosch, S.C. Mitchell, et al. "Automatic Segmentation of Echocardiographic Sequences by Active Appearance Motion Models". IEEE Trans Med Imag, vol. 21, p. 1374-1383, 2002.
    • (2002) IEEE Trans Med Imag , vol.21 , pp. 1374-1383
    • Bosch, J.G.1    Mitchell, S.C.2
  • 11
    • 58649097040 scopus 로고    scopus 로고
    • Side-by-side viewing of anatomically aligned left ventricular segments in three-dimensional stress echocardiography
    • February
    • A. Nemes, K.Y.E. Leung, et al. "Side-by-Side Viewing of Anatomically Aligned Left Ventricular Segments in Three-Dimensional Stress Echocardiography". Echocardiography, vol. 26, p. 189-195, February 2009.
    • (2009) Echocardiography , vol.26 , pp. 189-195
    • Nemes, A.1    Leung, K.Y.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.