메뉴 건너뛰기




Volumn , Issue , 2010, Pages 575-578

Challenges for high field clinical MRI

Author keywords

Clinical MRI; High frequency; Quadrature excitation; RF distribution; Transmit arrays

Indexed keywords

B1 FIELD; ENGINEERING CHALLENGES; HIGH FIELD; HIGH FREQUENCY; POWER DEPOSITION; REGULATORY GUIDELINES;

EID: 77955215846     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISBI.2010.5490281     Document Type: Conference Paper
Times cited : (2)

References (17)
  • 1
    • 46549092488 scopus 로고
    • An efficient, highly homogeneous radiofrequency coil for whole-body nmr imaging at 1.5-T
    • C.E. Hayes, W.A. Edelstein, J.F. Schenck, O.M. Mueller, M. Eash, An Efficient, Highly Homogeneous Radiofrequency Coil for Whole-Body Nmr Imaging at 1.5-T. J.Magn.Reson. 63 (1985) 622-628.
    • (1985) J.Magn.Reson. , vol.63 , pp. 622-628
    • Hayes, C.E.1    Edelstein, W.A.2    Schenck, J.F.3    Mueller, O.M.4    Eash, M.5
  • 3
    • 28444487453 scopus 로고    scopus 로고
    • Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high frequencies
    • C.M. Collins, W. Liu, B.J. Swift, M.B. Smith, Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high frequencies. Magn Reson.Med 54 (2005) 1327-1332.
    • (2005) Magn Reson.Med , vol.54 , pp. 1327-1332
    • Collins, C.M.1    Liu, W.2    Swift, B.J.3    Smith, M.B.4
  • 4
    • 0018190215 scopus 로고
    • RF magnetic field penetration, phase shift and power dissipation in biological tissue: Implications for NMR imaging
    • P.A. Bottomley, E.R. Andrew, RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imaging. Phys.Med Biol. 23 (1978) 630-643.
    • (1978) Phys. Med Biol. , vol.23 , pp. 630-643
    • Bottomley, P.A.1    Andrew, E.R.2
  • 5
    • 38949112082 scopus 로고    scopus 로고
    • Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject-dependent transmit phase measurements
    • G.J. Metzger, C. Snyder, C. Akgun, T. Vaughan, K. Ugurbil, P.F. van de Moortele, Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject-dependent transmit phase measurements. Magn Reson.Med 59 (2008) 396-409.
    • (2008) Magn Reson.Med , vol.59 , pp. 396-409
    • Metzger, G.J.1    Snyder, C.2    Akgun, C.3    Vaughan, T.4    Ugurbil, K.5    Van De Moortele, P.F.6
  • 6
    • 18444403725 scopus 로고    scopus 로고
    • MRI-monitored electromagnetic heating using iterative feedback control and phase interference mapping
    • B. Behnia, A.G. Webb, MRI-monitored electromagnetic heating using iterative feedback control and phase interference mapping. Conc.Magn.Reson.B 23B (2004) 1-15.
    • (2004) Conc.Magn.Reson.B , vol.23 B , pp. 1-15
    • Behnia, B.1    Webb, A.G.2
  • 7
    • 4043154817 scopus 로고    scopus 로고
    • Model-based optimization of phased arrays for electromagnetic hyperthermia
    • M.E. Kowalski, H.M. Jin, Model-based optimization of phased arrays for electromagnetic hyperthermia. IEEE Trans.Microwave Theory Tech. 52 (2004) 1964-1977.
    • (2004) IEEE Trans.Microwave Theory Tech. , vol.52 , pp. 1964-1977
    • Kowalski, M.E.1    Jin, H.M.2
  • 8
    • 0026153962 scopus 로고
    • Mathematical-methods for treatment planning in deep regional hyperthermia
    • D. Sullivan, Mathematical-Methods for Treatment Planning in Deep Regional Hyperthermia. IEEE Trans.Microwave Theory Tech. 39 (1991) 864-872.
    • (1991) IEEE Trans.Microwave Theory Tech. , vol.39 , pp. 864-872
    • Sullivan, D.1
  • 10
    • 18544369266 scopus 로고    scopus 로고
    • Closed-loop feedback control of phased-array microwave heating using thermal measurements from magnetic resonance imaging
    • B. Behnia, M. Suthar, A.G. Webb, Closed-loop feedback control of phased-array microwave heating using thermal measurements from magnetic resonance imaging. Conc.Magn.Reson.B 15 (2002) 101-110.
    • (2002) Conc. Magn. Reson. B , vol.15 , pp. 101-110
    • Behnia, B.1    Suthar, M.2    Webb, A.G.3
  • 11
    • 40449139930 scopus 로고    scopus 로고
    • A geometrically adjustable 16-channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla
    • G. Adriany, P.F. van de Moortele, J. Ritter, S. Moeller, E.J. Auerbach, C. Akgun, C.J. Snyder, T. Vaughan, K. Ugurbil, A geometrically adjustable 16- channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla. Magn Reson.Med 59 (2008) 590-597.
    • (2008) Magn Reson. Med , vol.59 , pp. 590-597
    • Adriany, G.1    Van De Moortele, P.F.2    Ritter, J.3    Moeller, S.4    Auerbach, E.J.5    Akgun, C.6    Snyder, C.J.7    Vaughan, T.8    Ugurbil, K.9
  • 16
    • 77955196525 scopus 로고
    • Analysis of skin, muscle and brachial arterial blood temperatures in the resting normal human forearm
    • H.H. Pennes, Analysis of Skin, Muscle and Brachial Arterial Blood Temperatures in the Resting Normal Human Forearm. American Journal of Physiology 155 (1948) 459.
    • (1948) American Journal of Physiology , vol.155 , pp. 459
    • Pennes, H.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.