메뉴 건너뛰기




Volumn , Issue , 2010, Pages 748-751

Non-uniformity correction using cosine functions basis and total variation constraint

Author keywords

Cosine basis; Non Uniformity; Total variation

Indexed keywords

COSINE FUNCTIONS; INTENSITY FLUCTUATIONS; LOWER LIMB; MUSCULAR DYSTROPHY; NMR IMAGES; NONUNIFORMITY; NONUNIFORMITY CORRECTION; PARAMETRIC MODELS; PATHOLOGICAL CASE; SUBCUTANEOUS FAT; TOTAL VARIATION;

EID: 77955203549     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISBI.2010.5490068     Document Type: Conference Paper
Times cited : (2)

References (12)
  • 1
    • 0032034233 scopus 로고    scopus 로고
    • Optimized homomorphic unsharp masking for MR grayscale inhomogeneity correction
    • BH. Brinkmann, A. Manduca, and RA. Robb, "Optimized homomorphic unsharp masking for MR grayscale inhomogeneity correction," IEEE Trans Med Imaging, vol. 2, pp. 291-294, 1998.
    • (1998) IEEE Trans Med Imaging , vol.2 , pp. 291-294
    • Brinkmann, B.H.1    Manduca, A.2    Robb, R.A.3
  • 2
    • 0037904043 scopus 로고    scopus 로고
    • A wavelet-based approximation of surface coil sensitivity profiles for correction of image intensity inhomogeneity and parallel imaging reconstruction
    • F. Lin, Y. Chen, J. Belliveau, and L. Wald, "A wavelet-based approximation of surface coil sensitivity profiles for correction of image intensity inhomogeneity and parallel imaging reconstruction," Human Brain Mapping, vol. 19, pp. 96 - 111, 2003.
    • (2003) Human Brain Mapping , vol.19 , pp. 96-111
    • Lin, F.1    Chen, Y.2    Belliveau, J.3    Wald, L.4
  • 4
    • 0031150141 scopus 로고    scopus 로고
    • Estimating the bias field of mr images
    • R. Guillemaud and M. Brady, "Estimating the bias field of mr images," IEEE Trans Med Imaging, vol. 16, pp. 238-251, 1997.
    • (1997) IEEE Trans Med Imaging , vol.16 , pp. 238-251
    • Guillemaud, R.1    Brady, M.2
  • 5
    • 0031987382 scopus 로고    scopus 로고
    • A nonparametric method for automatic correction of intensity nonuniformity in MRI data
    • J.G. Sled, A.P. Zijdenbos, and A.C. Evans, "A nonparametric method for automatic correction of intensity nonuniformity in MRI data," IEEE Trans Med Imaging, vol. 17, no. 1, pp. 87-97, 1998.
    • (1998) IEEE Trans Med Imaging , vol.17 , Issue.1 , pp. 87-97
    • Sled, J.G.1    Zijdenbos, A.P.2    Evans, A.C.3
  • 6
    • 0033686471 scopus 로고    scopus 로고
    • Entropy minimization for automatic correction of intensity nonuniformity
    • JF. Mangin, "Entropy minimization for automatic correction of intensity nonuniformity," MMBIA, p. 162, 2000.
    • (2000) MMBIA , pp. 162
    • Mangin, J.F.1
  • 7
    • 0035544623 scopus 로고    scopus 로고
    • Retrospective correction of MR intensity inhomogeneity by information minimization
    • B. Likar, M. A. Viergever, and F. Pernus, "Retrospective correction of MR intensity inhomogeneity by information minimization," IEEE Trans Med Imaging, vol. 20, no. 12, pp. 1398-1410, 2001.
    • (2001) IEEE Trans Med Imaging , vol.20 , Issue.12 , pp. 1398-1410
    • Likar, B.1    Viergever, M.A.2    Pernus, F.3
  • 8
    • 0033623981 scopus 로고    scopus 로고
    • Parametric estimate of intensity inhomogeneities applied to MRI
    • M. Styner, Szckely G. Brechbuhler, C. and, and G. Gerig, "Parametric estimate of intensity inhomogeneities applied to MRI," IEEE Trans Med Imaging, vol. 19, pp. 153-165, 2001.
    • (2001) IEEE Trans Med Imaging , vol.19 , pp. 153-165
    • Styner, M.1    Szckely, G.2    Brechbuhler, C.3    Gerig, G.4
  • 9
    • 0029263826 scopus 로고
    • Retrospective correction of intensity inhomogeneities in MRI
    • P.H. Meyer, C.R. and Bland and J. Pipe, "Retrospective correction of intensity inhomogeneities in MRI," IEEE Trans Med Imaging, vol. 14, pp. 36-41, 1995.
    • (1995) IEEE Trans Med Imaging , vol.14 , pp. 36-41
    • Meyer, P.H.1    Bland, C.R.2    Pipe, J.3
  • 10
    • 31744442025 scopus 로고    scopus 로고
    • Intensity non-uniformity correction in mri: Existing methods and their validation
    • Boubakeur Belaroussi, Julien Milles, Sabin Carme, Yue Min Zhu, and Hugues Benoit-Cattin, "Intensity non-uniformity correction in mri: Existing methods and their validation," Medical Image Analysis, vol. 10, no. 2, pp. 234 - 246, 2006.
    • (2006) Medical Image Analysis , vol.10 , Issue.2 , pp. 234-246
    • Belaroussi, B.1    Milles, J.2    Carme, S.3    Zhu, Y.M.4    Benoit-Cattin, H.5
  • 11
    • 51449106071 scopus 로고    scopus 로고
    • Dixon techniques for water and fat imaging
    • J. Ma, "Dixon techniques for water and fat imaging," Journal of Magnetic Resonance Imaging, vol. 28, no. 3, pp. 543-558, 2008.
    • (2008) Journal of Magnetic Resonance Imaging , vol.28 , Issue.3 , pp. 543-558
    • Ma, J.1
  • 12
    • 77955208499 scopus 로고    scopus 로고
    • A general method for correction of intensity inhomogeniety in two point dixon imaging
    • O. Friman, O. D. Leinhard, P. Lundberg, and M. Borga, "A general method for correction of intensity inhomogeniety in two point dixon imaging," in ISMRM, 2009, p. 4637.
    • (2009) ISMRM , pp. 4637
    • Friman, O.1    Leinhard, O.D.2    Lundberg, P.3    Borga, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.