메뉴 건너뛰기




Volumn , Issue , 2010, Pages 712-715

Cramér Rao Bound analysis of joint B1/T1 mapping methods in MRI

Author keywords

B1 mapping; Cramer Rao Bound; Magnetic resonance imaging; T1 mapping

Indexed keywords

B1 MAPPING; JOINT ESTIMATION; MAPPING METHOD; PULSE SEQUENCE; RELAXATION EFFECT; RF FIELDS; T1 MAPPING; TRADE OFF;

EID: 77955183904     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISBI.2010.5490075     Document Type: Conference Paper
Times cited : (9)

References (8)
  • 2
    • 33744956872 scopus 로고    scopus 로고
    • Saturated double-angle method for rapid B1+ mapping
    • June
    • C. H. Cunningham, J. M. Pauly, and K. S. Nayak, "Saturated double-angle method for rapid B1+ mapping," Mag. Res. Med., vol. 55, no. 6, pp. 1326-33, June 2006.
    • (2006) Mag. Res. Med. , vol.55 , Issue.6 , pp. 1326-1333
    • Cunningham, C.H.1    Pauly, J.M.2    Nayak, K.S.3
  • 3
    • 67049109394 scopus 로고    scopus 로고
    • B1+ interferometry for the calibration of RF transmitter arrays
    • June
    • D. O. Brunner and K. P. Pruessmann, "B1+ interferometry for the calibration of RF transmitter arrays," Mag. Res. Med., vol. 61, no. 6, pp. 1480-8, June 2009.
    • (2009) Mag. Res. Med. , vol.61 , Issue.6 , pp. 1480-1488
    • Brunner, D.O.1    Pruessmann, K.P.2
  • 4
    • 33644813235 scopus 로고    scopus 로고
    • Rapid high-resolution T1 mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity
    • Mar.
    • H-L. M. Cheng and G. A. Wright, "Rapid high-resolution T1 mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity," Mag. Res. Med., vol. 55, no. 3, pp. 566-74, Mar. 2006.
    • (2006) Mag. Res. Med. , vol.55 , Issue.3 , pp. 566-574
    • Cheng, H.-L.M.1    Wright, G.A.2
  • 6
    • 0037370514 scopus 로고    scopus 로고
    • Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
    • Mar.
    • S. C. L. Deoni, B. K. Rutt, and T. M. Peters, "Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state," Mag. Res. Med., vol. 49, no. 3, pp. 515-26, Mar. 2003.
    • (2003) Mag. Res. Med. , vol.49 , Issue.3 , pp. 515-526
    • Deoni, S.C.L.1    Rutt, B.K.2    Peters, T.M.3
  • 7
    • 36348998721 scopus 로고    scopus 로고
    • Fast, accurate, and precise mapping of the RF field in vivo using the 180° signal null
    • Sept.
    • N. G. Dowell and P. S. Tofts, "Fast, accurate, and precise mapping of the RF field in vivo using the 180° signal null," Mag. Res. Med., vol. 58, no. 3, pp. 622-30, Sept. 2007.
    • (2007) Mag. Res. Med. , vol.58 , Issue.3 , pp. 622-630
    • Dowell, N.G.1    Tofts, P.S.2
  • 8
    • 33846078031 scopus 로고    scopus 로고
    • Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field
    • Jan.
    • V. L. Yarnykh, "Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field," Mag. Res. Med., vol. 57, no. 1, pp. 192-200, Jan. 2007.
    • (2007) Mag. Res. Med. , vol.57 , Issue.1 , pp. 192-200
    • Yarnykh, V.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.