Hybrid cooled data center using above ambient liquid cooling

Author keywords

Cooling; Data center; Hybrid; Liquid; Model; Water

Indexed keywords

ANALYTICAL MODEL; BASELINE DATA; CHILLED WATER; COOLING DATA; DATA CENTER; DATA CENTERS; DATA SHEETS; DUAL EFFECT; ENERGY CONSUMPTION; ENERGY SAVING; ENVIRONMENTAL CONDITIONS; ESTIMATED COSTS; LARGE DATA; LIQUID COOLING; LIQUID MODELS; POWER DENSITIES; SYSTEM COMPONENTS; WARM WATER;

EID: 77955178375     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ITHERM.2010.5501426     Document Type: Conference Paper
Times cited : (23)

References (16)
  • 1
    • 77955200302 scopus 로고    scopus 로고
    • Leading the Technology Industry into Green IT in the Data Center, Profitability and Efficiency are the Same
    • Presented at the
    • Belady, Christian, Leading the Technology Industry into Green IT In the Data Center, Profitability and Efficiency are the Same, Presented at the Virtual Energy Forum, June 10, 2008
    • Virtual Energy Forum, June 10, 2008
    • Belady, C.1
  • 3
    • 77950653286 scopus 로고    scopus 로고
    • Version 1.0, 30, EUROPEAN COMMISSION, DIRECTORATE-GENERAL JRC, JOINT RESEARCH CENTRE, Institute for Energy, Renewable Energies Unit, October
    • Code of Conduct on Data Centres Energy Efficiency, Version 1.0, 30, EUROPEAN COMMISSION, DIRECTORATE-GENERAL JRC, JOINT RESEARCH CENTRE, Institute for Energy, Renewable Energies Unit, October 2008
    • (2008) Code of Conduct on Data Centres Energy Efficiency
  • 5
    • 84885247838 scopus 로고    scopus 로고
    • Green Grid Metrics: Describing Data Center Power Efficiency
    • Feb 12
    • Green Grid Metrics: Describing Data Center Power Efficiency, Technical Committee White Paper, Feb 12, 2007
    • (2007) Technical Committee White Paper
  • 7
    • 34547966757 scopus 로고    scopus 로고
    • Ph.D., Staff Scientist, Lawrence Berkeley National Laboratory and Consulting Professor, Stanford University, February 15
    • Koomey, Jonathan G., Ph.D., ESTIMATING TOTAL POWER CONSUMPTION BY SERVERS INTHE U.S. AND THE WORLD, Staff Scientist, Lawrence Berkeley National Laboratory and Consulting Professor, Stanford University, February 15, 2007
    • (2007) Estimating Total Power Consumption by Servers inthe U.S. and the World
    • Koomey, J.G.1
  • 11
    • 77955218402 scopus 로고    scopus 로고
    • Energy Flow in the Information Technology Stack: Coefficient of Performance of the Ensemble and its Impact on the Total Cost of Ownership
    • Presented at the Hewlett-Packard Development Company, L.P
    • Patel, Chandrakant, Ratnesh Sharma, Cullen Bash, and Monem Beitelmal. Energy Flow in the Information Technology Stack: Coefficient of Performance of the Ensemble and its Impact on the Total Cost of Ownership. Presented at the International Mechanical Engineering Congress and Exposition, March 21, 2006. Hewlett-Packard Development Company, L.P.
    • International Mechanical Engineering Congress and Exposition, March 21, 2006
    • Patel, C.1    Sharma, R.2    Bash, C.3    Beitelmal, M.4
  • 14
    • 77955207051 scopus 로고
    • SPX Cooling Technologies, Document H-001A, October
    • SPX Cooling Technologies, Cooling Tower Energy and Its Management, Document H-001A, October 1982
    • (1982) Cooling Tower Energy and Its Management
  • 16
    • 79960646928 scopus 로고    scopus 로고
    • U.S. Environmental Protection Agency Energy Star Program, Public Law August 2
    • U.S. Environmental Protection Agency Energy Star Program, Report to Congress on Server and Data Center Energy Efficiency, Public Law 109-431, August 2, 2007
    • (2007) Report to Congress on Server and Data Center Energy Efficiency , pp. 109-431


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.