메뉴 건너뛰기




Volumn 64, Issue 2, 2010, Pages 574-585

Total removal of unwanted harmonic peaks (TruHARP) MRI for single breath-hold high-resolution myocardial motion and strain quantification

Author keywords

Cardiac motion; HARP; MRI; Strain quantification; Tagging

Indexed keywords

IMAGE ACQUISITION; MAGNETIC RESONANCE IMAGING; MONTE CARLO METHODS;

EID: 77955123124     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22403     Document Type: Article
Times cited : (14)

References (38)
  • 1
    • 0346750821 scopus 로고    scopus 로고
    • Noninvasive Imaging of Myocardial Viability: Current Techniques and Future Developments
    • DOI 10.1161/01.RES.0000103863.40055.E8
    • Wu KC, Lima JA. Noninvasive imaging of myocardial viability: current techniques and future developments. Circ Res 2003;93:1146-1158. (Pubitemid 37543055)
    • (2003) Circulation Research , vol.93 , Issue.12 , pp. 1146-1158
    • Wu, K.C.1    Lima, J.A.C.2
  • 7
    • 0033609496 scopus 로고    scopus 로고
    • Alterations in the local myocardial motion pattern in patients suffering from pressure overload due to aortic stenosis
    • Stuber M, Scheidegger MB, Fischer SE, Nagel E, Steinemann F, Hess OM, Boesiger P. Alterations in the local myocardial motion pattern in patients suffering from pressure overload due to aortic stenosis. Circulation 1999;100:361-368. (Pubitemid 29362405)
    • (1999) Circulation , vol.100 , Issue.4 , pp. 361-368
    • Stuber, M.1    Scheidegger, M.B.2    Fischer, S.E.3    Nagel, E.4    Steinemann, F.5    Hess, O.M.6    Boesiger, P.7
  • 8
    • 0032948629 scopus 로고    scopus 로고
    • Noninvasive diagnosis of ischemia-induced wall motion abnormalities with the use of high-dose dobutamine stress MRI: Comparison with dobutamine stress echocardiography
    • Nagel E, Lehmkuhl HB, Bocksch W, Klein C, Vogel U, Frantz E, Ellmer A, Dreysse S, Fleck E. Noninvasive diagnosis of ischemia-induced wall motion abnormalities with the use of high-dose dobutamine stress MRI: comparison with dobutamine stress echocardiography. Circulation 1999;99:763-770.
    • (1999) Circulation , vol.99 , pp. 763-770
    • Nagel, E.1    Lehmkuhl, H.B.2    Bocksch, W.3    Klein, C.4    Vogel, U.5    Frantz, E.6    Ellmer, A.7    Dreysse, S.8    Fleck, E.9
  • 9
    • 0023737101 scopus 로고
    • Human heart: Tagging with MR imaging - A method for noninvasive assessment of myocardial motion
    • Zerhouni EA, Parish DM, Rogers WJ, Yang A, Shapiro EP. Human heart: tagging with MR imaging - a method for noninvasive assessment of myocardial motion. Radiology 1988;169:59-63.
    • (1988) Radiology , vol.169 , pp. 59-63
    • Zerhouni, E.A.1    Parish, D.M.2    Rogers, W.J.3    Yang, A.4    Shapiro, E.P.5
  • 10
    • 0024318208 scopus 로고
    • MR imaging of motion with spatial modulation of magnetization
    • Axel L, Dougherty L. MR imaging of motion with spatial modulation of magnetization. Radiology 1989;171:841-845. (Pubitemid 19134952)
    • (1989) Radiology , vol.171 , Issue.3 , pp. 841-845
    • Axel, L.1    Dougherty, L.2
  • 11
    • 0032752454 scopus 로고    scopus 로고
    • Cardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging
    • Osman NF, Kerwin WS, McVeigh ER, Prince JL. Cardiac motion tracking using CINE harmonic phase (HARP) magnetic resonance imaging. Magn Reson Med 1999;42:1048-1060.
    • (1999) Magn Reson Med , vol.42 , pp. 1048-1060
    • Osman, N.F.1    Kerwin, W.S.2    McVeigh, E.R.3    Prince, J.L.4
  • 13
    • 0033185649 scopus 로고    scopus 로고
    • High-Resolution Strain Analysis of the Human Heart with Fast-DENSE
    • Aletras AH, Balaban RS, Wen H. High-resolution strain analysis of the human heart with fast-DENSE. J Magn Reson 1999;140:41-57. (Pubitemid 129609615)
    • (1999) Journal of Magnetic Resonance , vol.140 , Issue.1 , pp. 41-57
    • Aletras, A.H.1    Balaban, R.S.2    Wen, H.3
  • 14
    • 0033093565 scopus 로고    scopus 로고
    • DENSE: Displacement Encoding with Stimulated Echoes in Cardiac Functional MRI
    • Aletras AH, Ding S, Balaban RS, Wen H. DENSE: displacement encoding with stimulated echoes in cardiac functional MRI. J Magn Reson 1999;137:247-252. (Pubitemid 129608248)
    • (1999) Journal of Magnetic Resonance , vol.137 , Issue.1 , pp. 247-252
    • Aletras, A.H.1    Ding, S.2    Balaban, R.S.3    Wen, H.4
  • 15
    • 33749236810 scopus 로고    scopus 로고
    • Measuring mechanical function in the failing heart
    • McVeigh E. Measuring mechanical function in the failing heart. J Electrocardiol 2006;39(4 suppl):S24-27.
    • (2006) J Electrocardiol , vol.39 , Issue.4 SUPPL.
    • McVeigh, E.1
  • 16
    • 0034909497 scopus 로고    scopus 로고
    • Imaging longitudinal cardiac strain on short-axis images using strain-encoded MRI
    • Osman NF, Sampath S, Atalar E, Prince JL. Imaging longitudinal cardiac strain on short-axis images using strain-encoded MRI. Magn Reson Med 2001;46:324-334.
    • (2001) Magn Reson Med , vol.46 , pp. 324-334
    • Osman, N.F.1    Sampath, S.2    Atalar, E.3    Prince, J.L.4
  • 17
    • 57049090618 scopus 로고    scopus 로고
    • A combined harmonic phase and strain-encoded pulse sequence for measuring three-dimensional strain
    • Sampath S, Osman NF, Prince JL. A combined harmonic phase and strain-encoded pulse sequence for measuring three-dimensional strain. Magn Reson Imaging 2009;27:55-61.
    • (2009) Magn Reson Imaging , vol.27 , pp. 55-61
    • Sampath, S.1    Osman, N.F.2    Prince, J.L.3
  • 19
    • 4744363620 scopus 로고    scopus 로고
    • Displacement-encoded cardiac MRI using cosine and sine modulation to eliminate (CANSEL) artifact-generating echoes
    • Epstein FH, Gilson WD. Displacement-encoded cardiac MRI using cosine and sine modulation to eliminate (CANSEL) artifact-generating echoes. Magn Reson Med 2004;52:774-781.
    • (2004) Magn Reson Med , vol.52 , pp. 774-781
    • Epstein, F.H.1    Gilson, W.D.2
  • 21
    • 0034851890 scopus 로고    scopus 로고
    • Mixed echo train acquisition displacement encoding with stimulated echoes: An optimized DENSE method for in vivo functional imaging of the human heart
    • DOI 10.1002/mrm.1223
    • Aletras AH, Wen H. Mixed echo train acquisition displacement encoding with stimulated echoes: an optimized DENSE method for in vivo functional imaging of the human heart. Magn Reson Med 2001;46:523-534. (Pubitemid 32831328)
    • (2001) Magnetic Resonance in Medicine , vol.46 , Issue.3 , pp. 523-534
    • Aletras, A.H.1    Wen, H.2
  • 22
    • 3142565131 scopus 로고    scopus 로고
    • Meta-DENSE complex acquisition for reduced intravoxel dephasing
    • Aletras AH, Arai AE. Meta-DENSE complex acquisition for reduced intravoxel dephasing. J Magn Reson 2004;169:246-249.
    • (2004) J Magn Reson , vol.169 , pp. 246-249
    • Aletras, A.H.1    Arai, A.E.2
  • 23
    • 33750609509 scopus 로고    scopus 로고
    • Selective suppression of artifact-generating echoes in cine DENSE using through-plane dephasing
    • DOI 10.1002/mrm.21058
    • Zhong X, Spottiswoode BS, Cowart EA, Gilson WD, Epstein FH. Selective suppression of artifact-generating echoes in cine DENSE using through-plane dephasing. Magn Reson Med 2006;56:1126-1131. (Pubitemid 44691356)
    • (2006) Magnetic Resonance in Medicine , vol.56 , Issue.5 , pp. 1126-1131
    • Zhong, X.1    Spottiswoode, B.S.2    Cowart, E.A.3    Gilson, W.D.4    Epstein, F.H.5
  • 25
    • 1342329974 scopus 로고    scopus 로고
    • Myocardial Tissue Tracking with Two-dimensional Cine Displacement-encoded MR Imaging: Development and Initial Evaluation
    • DOI 10.1148/radiol.2303021213
    • Kim D, Gilson WD, Kramer CM, Epstein FH. Myocardial tissue tracking with two-dimensional cine displacement-encoded MR imaging: development and initial evaluation. Radiology 2004;230:862-871. (Pubitemid 38252888)
    • (2004) Radiology , vol.230 , Issue.3 , pp. 862-871
    • Kim, D.1    Gilson, W.D.2    Kramer, C.M.3    Epstein, F.H.4
  • 31
    • 0017851927 scopus 로고
    • On the use of windows for harmonic analysis with the discrete Fourier transform
    • Harris FJ. Use of windows for harmonic-analysis with discrete Fourier- transform. Proc IEEE 1978;66:51-83. (Pubitemid 8338069)
    • (1978) Proceedings of the IEEE , vol.66 , Issue.1 , pp. 51-83
    • Harris, F.J.1
  • 35
    • 0028396731 scopus 로고
    • Optimization of tag thickness for measuring position with magnetic resonance imaging
    • Atalar E, McVeigh ER. Optimization of tag thickness for measuring position with magnetic resonance imaging. IEEE Trans Med Imaging 1994;13:152-160.
    • (1994) IEEE Trans Med Imaging , vol.13 , pp. 152-160
    • Atalar, E.1    McVeigh, E.R.2
  • 37
    • 34547793773 scopus 로고    scopus 로고
    • Three-dimensional magnetic resonance myocardial motion tracking from a single image plane
    • Abd-Elmoniem KZ, Osman NF, Prince JL, Stuber M. Three-dimensional magnetic resonance myocardial motion tracking from a single image plane. Magn Reson Med 2007;58:92-102.
    • (2007) Magn Reson Med , vol.58 , pp. 92-102
    • Abd-Elmoniem, K.Z.1    Osman, N.F.2    Prince, J.L.3    Stuber, M.4
  • 38
    • 54249106864 scopus 로고    scopus 로고
    • Direct three-dimensional myocardial strain tensor quantification and tracking using zHARP
    • Abd-Elmoniem KZ, Stuber M, Prince JL. Direct three-dimensional myocardial strain tensor quantification and tracking using zHARP. Med Image Anal 2008;12:778-786.
    • (2008) Med Image Anal , vol.12 , pp. 778-786
    • Abd-Elmoniem, K.Z.1    Stuber, M.2    Prince, J.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.