-
1
-
-
0031239099
-
Micromodular implants provide electrical stimulation of paralyzed muscles and limbs
-
Sep
-
T. Cameron, G. E. Loeb, R. A. Peck, and J. H. Schulman et al., "Micromodular implants provide electrical stimulation of paralyzed muscles and limbs," IEEE Trans. Biomed. Eng., vol. 44, no. 9, pp. 781-790, Sep. 1997.
-
(1997)
IEEE Trans. Biomed. Eng
, vol.44
, Issue.9
, pp. 781-790
-
-
Cameron, T.1
Loeb, G.E.2
Peck, R.A.3
Schulman, J.H.4
-
2
-
-
33745067524
-
The BION devices: Injectable interfaces with peripheral nerves and muscles
-
May
-
G. E. Loeb, F. J. Richmond, and L. L. Baker, "The BION devices: Injectable interfaces with peripheral nerves and muscles," Neurosurgical Focus, vol. 20, no. 5, p. E2, May 2006.
-
(2006)
Neurosurgical Focus
, vol.20
, Issue.5
-
-
Loeb, G.E.1
Richmond, F.J.2
Baker, L.L.3
-
3
-
-
1542377573
-
First clinical experience with BION implants for therapeutic electrical stimulation
-
A. C. D. Salter, S. D. Bagg, J. L. Creasy, and C. Romano et al., "First clinical experience with BION implants for therapeutic electrical stimulation," Neuromodulation, vol. 7, no. 1, pp. 38-47, 2004.
-
(2004)
Neuromodulation
, vol.7
, Issue.1
, pp. 38-47
-
-
Salter, A.C.D.1
Bagg, S.D.2
Creasy, J.L.3
Romano, C.4
-
5
-
-
24144498693
-
Three-dimensional topography of the motor endplates of the rat gastrocnemius muscle
-
Sep
-
D. Prodanov, M. A. Thil, E. Marani, J. Delbeke, and J. Holsheimer, "Three-dimensional topography of the motor endplates of the rat gastrocnemius muscle," Muscle Nerve, vol. 32, no. 3, pp. 292-302, Sep. 2005.
-
(2005)
Muscle Nerve
, vol.32
, Issue.3
, pp. 292-302
-
-
Prodanov, D.1
Thil, M.A.2
Marani, E.3
Delbeke, J.4
Holsheimer, J.5
-
6
-
-
0032147082
-
Effects of regional stimulation using a miniature stimulator implanted in feline posterior biceps femoris
-
Aug
-
T. Cameron, F. J. R. Richmond, and G. E. Loeb, "Effects of regional stimulation using a miniature stimulator implanted in feline posterior biceps femoris," IEEE Trans. Biomed. Eng., vol. 45, no. 8, pp. 1036-1043, Aug. 1998.
-
(1998)
IEEE Trans. Biomed. Eng
, vol.45
, Issue.8
, pp. 1036-1043
-
-
Cameron, T.1
Richmond, F.J.R.2
Loeb, G.E.3
-
7
-
-
0024634621
-
Nonlinear muscle recruitment during intramuscular and nerve stimulation
-
Spring
-
J. A. Gruner and C. P. Mason, "Nonlinear muscle recruitment during intramuscular and nerve stimulation," J. Rehabil. Res. Develop., vol. 26, no. 2, pp. 1-16, Spring, 1989.
-
(1989)
J. Rehabil. Res. Develop
, vol.26
, Issue.2
, pp. 1-16
-
-
Gruner, J.A.1
Mason, C.P.2
-
8
-
-
0034283609
-
Recruitment properties of intramuscular and nerve trunk stimulating electrodes
-
Sep
-
K. Singh, F. J. R. Richmond, and G. E. Loeb, "Recruitment properties of intramuscular and nerve trunk stimulating electrodes," IEEE Trans. Rehabil. Eng., vol. 8, no. 3, pt. 3, pp. 276-285, Sep. 2000.
-
(2000)
IEEE Trans. Rehabil. Eng
, vol.8
, Issue.3 PART. 3
, pp. 276-285
-
-
Singh, K.1
Richmond, F.J.R.2
Loeb, G.E.3
-
9
-
-
0023696364
-
Effects of waveform on comfort during neuromuscular electrical stimulation
-
L. L. Baker, B. R. Bowman, and D. R. McNeal, "Effects of waveform on comfort during neuromuscular electrical stimulation," Clinical Orthopedics Related Res., vol. 233, pp. 75-85, 1988.
-
(1988)
Clinical Orthopedics Related Res
, vol.233
, pp. 75-85
-
-
Baker, L.L.1
Bowman, B.R.2
McNeal, D.R.3
-
10
-
-
0021875811
-
Effects of waveform parameters on comfort during transcutaneous neuromuscular stimulation
-
B. R. Bowman and L. L. Baker, "Effects of waveform parameters on comfort during transcutaneous neuromuscular stimulation," Ann. Biomed. Eng., vol. 13, no. 4, pp. 59-74, 1985.
-
(1985)
Ann. Biomed. Eng
, vol.13
, Issue.4
, pp. 59-74
-
-
Bowman, B.R.1
Baker, L.L.2
-
11
-
-
0003129972
-
Non-myelinated afferent fibres from mammalian skeletal muscle
-
A. Iggo, "Non-myelinated afferent fibres from mammalian skeletal muscle," J. Physiol. (Lond), vol. 155, pp. 52-53, 1961.
-
(1961)
J. Physiol. (Lond)
, vol.155
, pp. 52-53
-
-
Iggo, A.1
-
12
-
-
0022554002
-
Group III and IV receptors of skeletal muscle
-
V. C. Abrahams, "Group III and IV receptors of skeletal muscle," Can. J. Physiol. Pharmacol., vol. 64, pp. 509-514, 1986.
-
(1986)
Can. J. Physiol. Pharmacol
, vol.64
, pp. 509-514
-
-
Abrahams, V.C.1
-
13
-
-
0027076129
-
The influence of mechanical stimuli and of acetylsalicylic acid on the discharges of slowly conducting afferent units from normal and inflamed muscle in the rat
-
B. Diehl, U. Hoheisel, and S. Mense, "The influence of mechanical stimuli and of acetylsalicylic acid on the discharges of slowly conducting afferent units from normal and inflamed muscle in the rat," Exp. Brain Res., vol. 92, pp. 431-440, 1993.
-
(1993)
Exp. Brain Res
, vol.92
, pp. 431-440
-
-
Diehl, B.1
Hoheisel, U.2
Mense, S.3
-
14
-
-
0025913571
-
Properties of implanted electrodes for functional electrical stimulation
-
D. Popovic, T. Gordon, V. F. Rafuse, and A. Prochazka, "Properties of implanted electrodes for functional electrical stimulation," Ann. Biomed. Eng., vol. 19, no. 3, pp. 303-316, 1991.
-
(1991)
Ann. Biomed. Eng
, vol.19
, Issue.3
, pp. 303-316
-
-
Popovic, D.1
Gordon, T.2
Rafuse, V.F.3
Prochazka, A.4
-
15
-
-
0005780246
-
-
R. Bannister, Ed, 6th ed. Oxford, U.K, Oxford Univ. Press
-
R. Bannister, Ed., Brain's Clinical Neurology, 6th ed. Oxford, U.K.: Oxford Univ. Press, 1985.
-
(1985)
Brain's Clinical Neurology
-
-
-
16
-
-
0031972655
-
Differences between the time constant of sensory and motor peripheral nerve fibers: Further studies and considerations
-
M. Panizza, J. Nilsson, J. R. Bradley, and S. E. Grill et al., "Differences between the time constant of sensory and motor peripheral nerve fibers: Further studies and considerations," Muscle Nerve, vol. 14, no. 1, pp. 48-54, 1998.
-
(1998)
Muscle Nerve
, vol.14
, Issue.1
, pp. 48-54
-
-
Panizza, M.1
Nilsson, J.2
Bradley, J.R.3
Grill, S.E.4
-
17
-
-
0035068673
-
Selective stimulation of cat sciatic nerve using an array of varying length microelectrodes
-
A. Braner, R. B. Stein, and R. A. Norman, "Selective stimulation of cat sciatic nerve using an array of varying length microelectrodes," J. Neurophysiol., vol. 85, pp. 1585-1594, 2001.
-
(2001)
J. Neurophysiol
, vol.85
, pp. 1585-1594
-
-
Braner, A.1
Stein, R.B.2
Norman, R.A.3
-
18
-
-
0024637198
-
Recruitment data for nerve cuff electrodes: Implications for design of implantable stimulators
-
Mar
-
D. R. McNeal, L. L. Baker, and J. T. Symons, "Recruitment data for nerve cuff electrodes: Implications for design of implantable stimulators," IEEE Trans. Biomed. Eng., vol. 36, no. 3, pp. 301-308, Mar. 1989.
-
(1989)
IEEE Trans. Biomed. Eng
, vol.36
, Issue.3
, pp. 301-308
-
-
McNeal, D.R.1
Baker, L.L.2
Symons, J.T.3
-
19
-
-
0003619685
-
-
4th Edition. Los Angeles, CA: Los Amigos Research and Education Institute
-
L. L. Baker, C. L. Wederich, D. R. McNeal, C. Newsam, and R. L Waters, Neuromuscular Electrical Stimulation - A Practical Guide 4th Edition. Los Angeles, CA: Los Amigos Research and Education Institute, 2000.
-
(2000)
Neuromuscular Electrical Stimulation - A Practical Guide
-
-
Baker, L.L.1
Wederich, C.L.2
McNeal, D.R.3
Newsam, C.4
Waters, R.L.5
-
20
-
-
0034946983
-
Visual analog scales: Do they have a role in the measurements of preferences for health states?
-
G. W. Torrance, D. Feeny, and W. Furlong, "Visual analog scales: Do they have a role in the measurements of preferences for health states?," Med. Decision Making, vol. 21, no. 4, pp. 329-334, 2001.
-
(2001)
Med. Decision Making
, vol.21
, Issue.4
, pp. 329-334
-
-
Torrance, G.W.1
Feeny, D.2
Furlong, W.3
-
21
-
-
0020783711
-
-
P. H. Gorman and J. T. Mortimer, The effect of stimulus parameters on the recruitment characteristics of direct nerve stimulation, IEEE Trans. Biomed. Eng., BE-BME-30, no. 7, pp. 407-414, Jul. 1983.
-
P. H. Gorman and J. T. Mortimer, "The effect of stimulus parameters on the recruitment characteristics of direct nerve stimulation," IEEE Trans. Biomed. Eng., vol. BE-BME-30, no. 7, pp. 407-414, Jul. 1983.
-
-
-
-
22
-
-
0022590426
-
Recruitment properties of monopolar and bipolar electrodes epimysial electrodes
-
P. A. Grandjean and J. T. Mortimer, "Recruitment properties of monopolar and bipolar electrodes epimysial electrodes," Ann. Biomed. Eng., vol. 14, no. 1, pp. 53-66, 1986.
-
(1986)
Ann. Biomed. Eng
, vol.14
, Issue.1
, pp. 53-66
-
-
Grandjean, P.A.1
Mortimer, J.T.2
-
23
-
-
0141621098
-
Prevention of muscle disuse atrophy by low-frequency functional electrical stimulation in rats
-
Sep
-
A. C. Dupont-Salter, F. J. R. Richmond, and G. E. Loeb, "Prevention of muscle disuse atrophy by low-frequency functional electrical stimulation in rats," IEEE Trans. Neural Syst. Rehabil. Eng., vol. 11, no. 3, pp. 218-226, Sep. 2003.
-
(2003)
IEEE Trans. Neural Syst. Rehabil. Eng
, vol.11
, Issue.3
, pp. 218-226
-
-
Dupont-Salter, A.C.1
Richmond, F.J.R.2
Loeb, G.E.3
-
24
-
-
0032831309
-
Measured and modeled properties of mammalian skeletal muscle I. the effects of post-activation potentiation on the time course and velocity dependencies of force production
-
I. E. Brown and G. E. Loeb, "Measured and modeled properties of mammalian skeletal muscle I. the effects of post-activation potentiation on the time course and velocity dependencies of force production," J. Muscle Res. Cell Motility, vol. 20, pp. 443-456, 1999.
-
(1999)
J. Muscle Res. Cell Motility
, vol.20
, pp. 443-456
-
-
Brown, I.E.1
Loeb, G.E.2
-
25
-
-
0033383557
-
Measured and modeled properties of mammalian skeletal muscle II. the effects of stimulus frequency on force-length and force-velocity relationships
-
I. E. Brown, E. J. Cheng, and G. E. Loeb, "Measured and modeled properties of mammalian skeletal muscle II. the effects of stimulus frequency on force-length and force-velocity relationships," J. Muscle Res. Cell Motility, vol. 20, pp. 627-643, 1999.
-
(1999)
J. Muscle Res. Cell Motility
, vol.20
, pp. 627-643
-
-
Brown, I.E.1
Cheng, E.J.2
Loeb, G.E.3
-
26
-
-
0034008383
-
Measured and modeled properties of mammalian skeletal muscle III. the effects of stimulus frequency on stretch-induced force enhancement and shortening-induced force depression
-
I. E. Brown and G. E. Loeb, "Measured and modeled properties of mammalian skeletal muscle III. the effects of stimulus frequency on stretch-induced force enhancement and shortening-induced force depression," J. Muscle Res. Cell Motility, vol. 21, pp. 21-31, 2000.
-
(2000)
J. Muscle Res. Cell Motility
, vol.21
, pp. 21-31
-
-
Brown, I.E.1
Loeb, G.E.2
-
27
-
-
0034050438
-
Measured and modeled properties of mammalian skeletal muscle IV. the dynamics of activation and deactivation
-
I. E. Brown and G. E. Loeb, "Measured and modeled properties of mammalian skeletal muscle IV. the dynamics of activation and deactivation," J. Muscle Res. Cell Motility, vol. 21, pp. 33-47, 2000.
-
(2000)
J. Muscle Res. Cell Motility
, vol.21
, pp. 33-47
-
-
Brown, I.E.1
Loeb, G.E.2
-
28
-
-
0027380714
-
The distal hindlimb musculature of the cat: Multiaxis moment arms at the ankle joint
-
R. P. Young, S. H. Scott, and G. E. Loeb, "The distal hindlimb musculature of the cat: Multiaxis moment arms at the ankle joint," Exp. Brain Res., vol. 96, pp. 141-151, 1993.
-
(1993)
Exp. Brain Res
, vol.96
, pp. 141-151
-
-
Young, R.P.1
Scott, S.H.2
Loeb, G.E.3
-
29
-
-
0028879848
-
Variable frequency stimulation patterns for the optimization of force during muscle fatigue. Muscle wisdom and the catch-like property
-
New York: Springer, ch. 16, pp
-
S. A. Binder-Macleod, "Variable frequency stimulation patterns for the optimization of force during muscle fatigue. Muscle wisdom and the catch-like property," in Advances in Experimental Medicine and Biology. New York: Springer, 1995, vol. 384, ch. 16, pp. 227-240.
-
(1995)
Advances in Experimental Medicine and Biology
, vol.384
, pp. 227-240
-
-
Binder-Macleod, S.A.1
-
30
-
-
33745994920
-
Selective activation of primary afferent fibers evaluated by sine-wave electrical stimulation
-
Mar
-
K. Koga, H. Furue, T. Toya, and N. Matsumoto et al., "Selective activation of primary afferent fibers evaluated by sine-wave electrical stimulation," Molecular Pain, vol. 1, pp. 1-13, Mar. 2005.
-
(2005)
Molecular Pain
, vol.1
, pp. 1-13
-
-
Koga, K.1
Furue, H.2
Toya, T.3
Matsumoto, N.4
-
31
-
-
0021182987
-
Compartmentalization of single muscle units in cat lateral gastrocnemius
-
A. W. English, "Compartmentalization of single muscle units in cat lateral gastrocnemius," Exp. Brain Res., vol. 56, pp. 361-368, 1984.
-
(1984)
Exp. Brain Res
, vol.56
, pp. 361-368
-
-
English, A.W.1
|