메뉴 건너뛰기




Volumn 20, Issue 3, 2010, Pages 437-448

Bowel preparation and colonoscopy technique to detect non-polypoid colorectal neoplasms

Author keywords

Bowel; Colon; Colon cancer screening; Colon preparation; Colonoscopy; Non polypoid colorectal neoplasm

Indexed keywords

ASCORBIC ACID; BISACODYL; COLYTE; GOLYTELY; HALFLYTELY; MOVIPREP; NULYTELY; TRYLYTE; UNCLASSIFIED DRUG;

EID: 77955062276     PISSN: 10525157     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.giec.2010.03.005     Document Type: Review
Times cited : (15)

References (41)
  • 1
    • 22344437810 scopus 로고    scopus 로고
    • Colorectal cancer in patients under close colonoscopic surveillance
    • Robertson D.J., Greenberg E.R., Beach M., et al. Colorectal cancer in patients under close colonoscopic surveillance. Gastroenterology 2005, 129(1):34-41.
    • (2005) Gastroenterology , vol.129 , Issue.1 , pp. 34-41
    • Robertson, D.J.1    Greenberg, E.R.2    Beach, M.3
  • 2
    • 33845490843 scopus 로고    scopus 로고
    • A call to action-measuring the quality of colonoscopy
    • Lieberman D. A call to action-measuring the quality of colonoscopy. N Engl J Med 2006, 355(24):2588-2589.
    • (2006) N Engl J Med , vol.355 , Issue.24 , pp. 2588-2589
    • Lieberman, D.1
  • 3
    • 34047172438 scopus 로고    scopus 로고
    • Colorectal cancer: a multipathway disease
    • Jass J.R. Colorectal cancer: a multipathway disease. Crit Rev Oncog 2006, 12(3-4):273-287.
    • (2006) Crit Rev Oncog , vol.12 , Issue.3-4 , pp. 273-287
    • Jass, J.R.1
  • 4
    • 52249115178 scopus 로고    scopus 로고
    • Nonpolypoid neoplastic lesions of the colorectal mucosa
    • Kudo S., Lambert R., Allen J.I., et al. Nonpolypoid neoplastic lesions of the colorectal mucosa. Gastrointest Endosc 2008, 68(Suppl 4):S3-47.
    • (2008) Gastrointest Endosc , vol.68 , Issue.SUPPL 4
    • Kudo, S.1    Lambert, R.2    Allen, J.I.3
  • 5
    • 20144385150 scopus 로고    scopus 로고
    • Update on the Paris classification of superficial neoplastic lesions in the digestive tract
    • Endoscopic Classification Review Group
    • Endoscopic Classification Review Group Update on the Paris classification of superficial neoplastic lesions in the digestive tract. Endoscopy 2005, 37(6):570-578.
    • (2005) Endoscopy , vol.37 , Issue.6 , pp. 570-578
  • 6
    • 40449138243 scopus 로고    scopus 로고
    • Prevalence of nonpolypoid (flat and depressed) colorectal neoplasms in asymptomatic and symptomatic adults
    • Soetikno R.M., Kaltenbach T., Rouse R.V., et al. Prevalence of nonpolypoid (flat and depressed) colorectal neoplasms in asymptomatic and symptomatic adults. JAMA 2008, 299(9):1027-1035.
    • (2008) JAMA , vol.299 , Issue.9 , pp. 1027-1035
    • Soetikno, R.M.1    Kaltenbach, T.2    Rouse, R.V.3
  • 7
    • 34548093304 scopus 로고    scopus 로고
    • Enhancing the quality of colonoscopy: the importance of bowel purgatives
    • Burke C.A., Church J.M. Enhancing the quality of colonoscopy: the importance of bowel purgatives. Gastrointest Endosc 2007, 66(3):565-573.
    • (2007) Gastrointest Endosc , vol.66 , Issue.3 , pp. 565-573
    • Burke, C.A.1    Church, J.M.2
  • 8
    • 0346811295 scopus 로고    scopus 로고
    • Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia
    • Harewood G.C., Sharma V.K., de Garmo P. Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia. Gastrointest Endosc 2003, 58(1):76-79.
    • (2003) Gastrointest Endosc , vol.58 , Issue.1 , pp. 76-79
    • Harewood, G.C.1    Sharma, V.K.2    de Garmo, P.3
  • 9
    • 14844319280 scopus 로고    scopus 로고
    • Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European multicenter study
    • Froehlich F., Wietlisbach V., Gonvers J.J., et al. Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European multicenter study. Gastrointest Endosc 2005, 61(3):378-384.
    • (2005) Gastrointest Endosc , vol.61 , Issue.3 , pp. 378-384
    • Froehlich, F.1    Wietlisbach, V.2    Gonvers, J.J.3
  • 10
    • 33845456094 scopus 로고    scopus 로고
    • Maximizing detection of adenomas and cancers during colonoscopy
    • Rex D.K. Maximizing detection of adenomas and cancers during colonoscopy. Am J Gastroenterol 2006, 101(12):2866-2877.
    • (2006) Am J Gastroenterol , vol.101 , Issue.12 , pp. 2866-2877
    • Rex, D.K.1
  • 11
    • 33750629333 scopus 로고    scopus 로고
    • The timing of bowel preparation before colonoscopy determines the quality of cleansing, and is a significant factor contributing to the detection of flat lesions: a randomized study
    • Parra-Blanco A., Nicolas-Perez D., Gimeno-Garcia A., et al. The timing of bowel preparation before colonoscopy determines the quality of cleansing, and is a significant factor contributing to the detection of flat lesions: a randomized study. World J Gastroenterol 2006, 12(38):6161-6166.
    • (2006) World J Gastroenterol , vol.12 , Issue.38 , pp. 6161-6166
    • Parra-Blanco, A.1    Nicolas-Perez, D.2    Gimeno-Garcia, A.3
  • 12
    • 33646361037 scopus 로고    scopus 로고
    • Guidelines for colonoscopy surveillance after polypectomy: a consensus update by the US Multi-Society Task Force on Colorectal Cancer and the American Cancer Society
    • Winawer S.J., Zauber A.G., Fletcher R.H., et al. Guidelines for colonoscopy surveillance after polypectomy: a consensus update by the US Multi-Society Task Force on Colorectal Cancer and the American Cancer Society. Gastroenterology 2006, 130(6):1872-1885.
    • (2006) Gastroenterology , vol.130 , Issue.6 , pp. 1872-1885
    • Winawer, S.J.1    Zauber, A.G.2    Fletcher, R.H.3
  • 14
    • 0041384509 scopus 로고    scopus 로고
    • Bowel preparation comparison: flavored versus unflavored colyte
    • Hayes A., Buffum M., Fuller D. Bowel preparation comparison: flavored versus unflavored colyte. Gastroenterol Nurs 2003, 26(3):106-109.
    • (2003) Gastroenterol Nurs , vol.26 , Issue.3 , pp. 106-109
    • Hayes, A.1    Buffum, M.2    Fuller, D.3
  • 15
    • 0027473351 scopus 로고
    • Colonic lavage solutions: plain versus flavored
    • Matter S.E., Rice P.S., Campbell D.R. Colonic lavage solutions: plain versus flavored. Am J Gastroenterol 1993, 88(1):49-52.
    • (1993) Am J Gastroenterol , vol.88 , Issue.1 , pp. 49-52
    • Matter, S.E.1    Rice, P.S.2    Campbell, D.R.3
  • 16
    • 1842538670 scopus 로고    scopus 로고
    • Validation of a new scale for the assessment of bowel preparation quality
    • Rostom A., Jolicoeur E. Validation of a new scale for the assessment of bowel preparation quality. Gastrointest Endosc 2004, 59(4):482-486.
    • (2004) Gastrointest Endosc , vol.59 , Issue.4 , pp. 482-486
    • Rostom, A.1    Jolicoeur, E.2
  • 17
    • 61549094968 scopus 로고    scopus 로고
    • The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research
    • Lai E.J., Calderwood A.H., Doros G., et al. The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research. Gastrointest Endosc 2009, 69(Suppl 3):620-625.
    • (2009) Gastrointest Endosc , vol.69 , Issue.SUPPL 3 , pp. 620-625
    • Lai, E.J.1    Calderwood, A.H.2    Doros, G.3
  • 18
    • 0031784228 scopus 로고    scopus 로고
    • Effectiveness of polyethylene glycol antegrade gut lavage bowel preparation for colonoscopy-timing is the key!
    • Church J.M. Effectiveness of polyethylene glycol antegrade gut lavage bowel preparation for colonoscopy-timing is the key!. Dis Colon Rectum 1998, 41(10):1223-1225.
    • (1998) Dis Colon Rectum , vol.41 , Issue.10 , pp. 1223-1225
    • Church, J.M.1
  • 19
    • 34547136190 scopus 로고    scopus 로고
    • Quality and effect of single dose versus split dose of polyethylene glycol bowel preparation for early-morning colonoscopy
    • Park J.S., Sohn C.I., Hwang S.J., et al. Quality and effect of single dose versus split dose of polyethylene glycol bowel preparation for early-morning colonoscopy. Endoscopy 2007, 39(7):616-619.
    • (2007) Endoscopy , vol.39 , Issue.7 , pp. 616-619
    • Park, J.S.1    Sohn, C.I.2    Hwang, S.J.3
  • 20
    • 0642376461 scopus 로고    scopus 로고
    • A randomized single-blind trial of whole versus split-dose polyethylene glycol-electrolyte solution for colonoscopy preparation
    • El Sayed A.M., Kanafani Z.A., Mourad F.H., et al. A randomized single-blind trial of whole versus split-dose polyethylene glycol-electrolyte solution for colonoscopy preparation. Gastrointest Endosc 2003, 58(1):36-40.
    • (2003) Gastrointest Endosc , vol.58 , Issue.1 , pp. 36-40
    • El Sayed, A.M.1    Kanafani, Z.A.2    Mourad, F.H.3
  • 21
    • 69949187152 scopus 로고    scopus 로고
    • A randomized clinical study evaluating the safety and efficacy of a new, reduced-volume, oral sulfate colon-cleansing preparation for colonoscopy
    • Di Palma J.A., Rodriguez R., McGowan J., et al. A randomized clinical study evaluating the safety and efficacy of a new, reduced-volume, oral sulfate colon-cleansing preparation for colonoscopy. Am J Gastroenterol 2009, 104(9):2275-2284.
    • (2009) Am J Gastroenterol , vol.104 , Issue.9 , pp. 2275-2284
    • Di Palma, J.A.1    Rodriguez, R.2    McGowan, J.3
  • 22
    • 0031016453 scopus 로고    scopus 로고
    • Cleansing ability and tolerance of three bowel preparations for colonoscopy
    • Frommer D. Cleansing ability and tolerance of three bowel preparations for colonoscopy. Dis Colon Rectum 1997, 40(1):100-104.
    • (1997) Dis Colon Rectum , vol.40 , Issue.1 , pp. 100-104
    • Frommer, D.1
  • 23
    • 34548023971 scopus 로고    scopus 로고
    • Comparison of two schedules (previous evening versus same morning) of bowel preparation for colonoscopy
    • Gupta T., Mandot A., Desai D., et al. Comparison of two schedules (previous evening versus same morning) of bowel preparation for colonoscopy. Endoscopy 2007, 39(8):706-709.
    • (2007) Endoscopy , vol.39 , Issue.8 , pp. 706-709
    • Gupta, T.1    Mandot, A.2    Desai, D.3
  • 24
    • 61349144368 scopus 로고    scopus 로고
    • Duration of the interval between the completion of bowel preparation and the start of colonoscopy predicts bowel-preparation quality
    • Siddiqui A.A., Yang K., Spechler S.J., et al. Duration of the interval between the completion of bowel preparation and the start of colonoscopy predicts bowel-preparation quality. Gastrointest Endosc 2009, 69(Suppl 3):700-706.
    • (2009) Gastrointest Endosc , vol.69 , Issue.SUPPL 3 , pp. 700-706
    • Siddiqui, A.A.1    Yang, K.2    Spechler, S.J.3
  • 25
    • 0032949314 scopus 로고    scopus 로고
    • Practice guidelines for preoperative fasting and the use of pharmacologic agents to reduce the risk of pulmonary aspiration: application to healthy patients undergoing elective procedures: a report by the American Society of Anesthesiologist Task Force on Preoperative Fasting
    • Practice guidelines for preoperative fasting and the use of pharmacologic agents to reduce the risk of pulmonary aspiration: application to healthy patients undergoing elective procedures: a report by the American Society of Anesthesiologist Task Force on Preoperative Fasting. Anesthesiology 1999, 90(3):896-905.
    • (1999) Anesthesiology , vol.90 , Issue.3 , pp. 896-905
  • 26
    • 0027404031 scopus 로고
    • Preoperative drinking does not affect gastric contents
    • Phillips S., Hutchinson S., Davidson T. Preoperative drinking does not affect gastric contents. Br J Anaesth 1993, 70(1):6-9.
    • (1993) Br J Anaesth , vol.70 , Issue.1 , pp. 6-9
    • Phillips, S.1    Hutchinson, S.2    Davidson, T.3
  • 27
    • 66549105650 scopus 로고    scopus 로고
    • Efficacy of prepackaged, low residual test meals with 4L polyethylene glycol versus a clear liquid diet with 4L polyethylene glycol bowel preparation: a randomized trial
    • Park D.I., Park S.H., Lee S.K., et al. Efficacy of prepackaged, low residual test meals with 4L polyethylene glycol versus a clear liquid diet with 4L polyethylene glycol bowel preparation: a randomized trial. J Gastroenterol Hepatol 2009, 24(6):988-991.
    • (2009) J Gastroenterol Hepatol , vol.24 , Issue.6 , pp. 988-991
    • Park, D.I.1    Park, S.H.2    Lee, S.K.3
  • 28
    • 0028821301 scopus 로고
    • [Improving the effect of orthograde colonic lavage with golytely solution by adding dimethicone]
    • [in German]
    • Kark W., Krebs-Richter H., Hotz J. Z Gastroenterol 1995, 33(1):20-23. [in German].
    • (1995) Z Gastroenterol , vol.33 , Issue.1 , pp. 20-23
    • Kark, W.1    Krebs-Richter, H.2    Hotz, J.3
  • 29
    • 0027759729 scopus 로고
    • Efficacy and tolerability of polyethylene glycol-electrolyte lavage solution with and without simethicone in the preparation of patients with inflammatory bowel disease for colonoscopy
    • Lazzaroni M., Petrillo M., Desideri S., et al. Efficacy and tolerability of polyethylene glycol-electrolyte lavage solution with and without simethicone in the preparation of patients with inflammatory bowel disease for colonoscopy. Aliment Pharmacol Ther 1993, 7(6):655-659.
    • (1993) Aliment Pharmacol Ther , vol.7 , Issue.6 , pp. 655-659
    • Lazzaroni, M.1    Petrillo, M.2    Desideri, S.3
  • 30
    • 0028783941 scopus 로고
    • The effectiveness of simethicone in improving visibility during colonoscopy when given with a sodium phosphate solution: a double-blind randomized study
    • Sudduth R.H., DeAngelis S., Sherman K.E., et al. The effectiveness of simethicone in improving visibility during colonoscopy when given with a sodium phosphate solution: a double-blind randomized study. Gastrointest Endosc 1995, 42(5):413-415.
    • (1995) Gastrointest Endosc , vol.42 , Issue.5 , pp. 413-415
    • Sudduth, R.H.1    DeAngelis, S.2    Sherman, K.E.3
  • 31
    • 67651240430 scopus 로고    scopus 로고
    • Improving quality of colonoscopy by adding simethicone to sodium phosphate bowel preparation
    • Tongprasert S., Sobhonslidsuk A., Rattanasiri S. Improving quality of colonoscopy by adding simethicone to sodium phosphate bowel preparation. World J Gastroenterol 2009, 15(24):3032-3037.
    • (2009) World J Gastroenterol , vol.15 , Issue.24 , pp. 3032-3037
    • Tongprasert, S.1    Sobhonslidsuk, A.2    Rattanasiri, S.3
  • 32
    • 0027279387 scopus 로고
    • The use of GoLYTELY and Dulcolax in combination in outpatient colonoscopy
    • Clarkston W.K., Smith O.J. The use of GoLYTELY and Dulcolax in combination in outpatient colonoscopy. J Clin Gastroenterol 1993, 17(2):146-148.
    • (1993) J Clin Gastroenterol , vol.17 , Issue.2 , pp. 146-148
    • Clarkston, W.K.1    Smith, O.J.2
  • 33
    • 0025947057 scopus 로고
    • Addition of senna improves colonoscopy preparation with lavage: a prospective randomized trial
    • Ziegenhagen D.J., Zehnter E., Tacke W., et al. Addition of senna improves colonoscopy preparation with lavage: a prospective randomized trial. Gastrointest Endosc 1991, 37(5):547-549.
    • (1991) Gastrointest Endosc , vol.37 , Issue.5 , pp. 547-549
    • Ziegenhagen, D.J.1    Zehnter, E.2    Tacke, W.3
  • 34
    • 34748845739 scopus 로고    scopus 로고
    • Clinical trial: an efficacy evaluation of reduced bisacodyl given as part of a polyethylene glycol electrolyte solution preparation prior to colonoscopy
    • DiPalma J.A., McGowan J., Cleveland M.V. Clinical trial: an efficacy evaluation of reduced bisacodyl given as part of a polyethylene glycol electrolyte solution preparation prior to colonoscopy. Aliment Pharmacol Ther 2007, 26(8):1113-1119.
    • (2007) Aliment Pharmacol Ther , vol.26 , Issue.8 , pp. 1113-1119
    • DiPalma, J.A.1    McGowan, J.2    Cleveland, M.V.3
  • 35
    • 0142245792 scopus 로고    scopus 로고
    • Comparison of reduced volume versus four liters sulfate-free electrolyte lavage solutions for colonoscopy colon cleansing
    • DiPalma J.A., Wolff B.G., Meagher A., et al. Comparison of reduced volume versus four liters sulfate-free electrolyte lavage solutions for colonoscopy colon cleansing. Am J Gastroenterol 2003, 98(10):2187-2191.
    • (2003) Am J Gastroenterol , vol.98 , Issue.10 , pp. 2187-2191
    • DiPalma, J.A.1    Wolff, B.G.2    Meagher, A.3
  • 36
    • 50649122767 scopus 로고    scopus 로고
    • Single-dose lubiprostone along with split-dose PEG solution without dietary restrictions for bowel cleansing prior to colonoscopy: a randomized, double-blind, placebo-controlled trial
    • Stengel J.Z., Jones D.P. Single-dose lubiprostone along with split-dose PEG solution without dietary restrictions for bowel cleansing prior to colonoscopy: a randomized, double-blind, placebo-controlled trial. Am J Gastroenterol 2008, 103(9):2224-2230.
    • (2008) Am J Gastroenterol , vol.103 , Issue.9 , pp. 2224-2230
    • Stengel, J.Z.1    Jones, D.P.2
  • 37
    • 61349190311 scopus 로고    scopus 로고
    • The outcome of a second preparation for colonoscopy after preparation failure in the first procedure
    • Ben-Horin S., Bar-Meir S., Avidan B. The outcome of a second preparation for colonoscopy after preparation failure in the first procedure. Gastrointest Endosc 2009, 69(Suppl 3):626-630.
    • (2009) Gastrointest Endosc , vol.69 , Issue.SUPPL 3 , pp. 626-630
    • Ben-Horin, S.1    Bar-Meir, S.2    Avidan, B.3
  • 38
    • 0034966746 scopus 로고    scopus 로고
    • Predictors of inadequate bowel preparation for colonoscopy
    • Ness R.M., Manam R., Hoen H., et al. Predictors of inadequate bowel preparation for colonoscopy. Am J Gastroenterol 2001, 96(6):1797-1802.
    • (2001) Am J Gastroenterol , vol.96 , Issue.6 , pp. 1797-1802
    • Ness, R.M.1    Manam, R.2    Hoen, H.3
  • 39
    • 66149192276 scopus 로고    scopus 로고
    • Impact of obesity on bowel preparation for colonoscopy
    • Borg B.B., Gupta N.K., Zuckerman G.R., et al. Impact of obesity on bowel preparation for colonoscopy. Clin Gastroenterol Hepatol 2009, 7(6):670-675.
    • (2009) Clin Gastroenterol Hepatol , vol.7 , Issue.6 , pp. 670-675
    • Borg, B.B.1    Gupta, N.K.2    Zuckerman, G.R.3
  • 40
    • 0034966715 scopus 로고    scopus 로고
    • A patient education program is cost-effective for preventing failure of endoscopic procedures in a gastroenterology department
    • Abuksis G., Mor M., Segal N., et al. A patient education program is cost-effective for preventing failure of endoscopic procedures in a gastroenterology department. Am J Gastroenterol 2001, 96(6):1786-1790.
    • (2001) Am J Gastroenterol , vol.96 , Issue.6 , pp. 1786-1790
    • Abuksis, G.1    Mor, M.2    Segal, N.3
  • 41
    • 77955060647 scopus 로고    scopus 로고
    • Better preparation, better screening, better adenoma detection
    • Raju G.S., Dasari C., Singh H. Better preparation, better screening, better adenoma detection. Gastrointest Endosc 2010, 71:AB328.
    • (2010) Gastrointest Endosc , vol.71
    • Raju, G.S.1    Dasari, C.2    Singh, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.