메뉴 건너뛰기




Volumn 16, Issue 4, 2010, Pages 422-429

CT venous phase venography with 64-detector CT angiography in the diagnosis of acute pulmonary embolism

Author keywords

64 detector CT; CT angiography; CT venography; deep venous thrombosis; pulmonary embolism

Indexed keywords

ADULT; ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DEEP VEIN THROMBOSIS; FEMALE; HUMAN; LUNG EMBOLISM; MAJOR CLINICAL STUDY; MALE; PHLEBOGRAPHY; PRIORITY JOURNAL; SCORING SYSTEM;

EID: 77954898929     PISSN: 10760296     EISSN: None     Source Type: Journal    
DOI: 10.1177/1076029609335502     Document Type: Article
Times cited : (10)

References (35)
  • 1
    • 33744503127 scopus 로고    scopus 로고
    • For the PIOPED II Investigators. Multidetector computed tomography for acute pulmonary embolism
    • Stein PD Fowler SE, Goodman LR, et al, for the PIOPED II Investigators. Multidetector computed tomography for acute pulmonary embolism. N Eng J Med. 2006 ; 354 (22). 2317-2327.
    • (2006) N Eng J Med , vol.354 , Issue.22 , pp. 2317-2327
    • Stein, P.D.1    Fowler, S.E.2    Goodman, L.R.3
  • 2
    • 39549087215 scopus 로고    scopus 로고
    • Venous thromboembolism: Indirect CT venography during CT pulmonary angiography-should the pelvis be imaged
    • Kalva SP, Jagannathan JP, Hahn PF, Wicky ST Venous thromboembolism: indirect CT venography during CT pulmonary angiography-should the pelvis be imaged ? Radiology. 2008 ; 246 (2). 605-611.
    • (2008) Radiology , vol.246 , Issue.2 , pp. 605-611
    • Kalva, S.P.1    Jagannathan, J.P.2    Hahn, P.F.3    Wicky, S.T.4
  • 3
    • 38849101085 scopus 로고    scopus 로고
    • Routine pelvic and lower extremity CT venography in patients undergoing pulmonary CT angiography
    • Hunsaker AR, Zou KH, Poh AC, et al. Routine pelvic and lower extremity CT venography in patients undergoing pulmonary CT angiography. AJR Am J Roentgenol. 2008 ; 190 (2). 322-326.
    • (2008) AJR Am J Roentgenol , vol.190 , Issue.2 , pp. 322-326
    • Hunsaker, A.R.1    Zou, K.H.2    Poh, A.C.3
  • 4
    • 0042174255 scopus 로고    scopus 로고
    • Contribution of indirect computed tomography venography to computed tomography angiography of the chest for the diagnosis of thromboembolic disease in two United States emergency departments
    • Richman PB, Wood J., Kasper DM, et al. Contribution of indirect computed tomography venography to computed tomography angiography of the chest for the diagnosis of thromboembolic disease in two United States emergency departments. J Thromb Haemost. 2003 ; 1 (4). 652-657.
    • (2003) J Thromb Haemost , vol.1 , Issue.4 , pp. 652-657
    • Richman, P.B.1    Wood, J.2    Kasper, D.M.3
  • 5
    • 10644231853 scopus 로고    scopus 로고
    • Diagnosing pulmonary embolism with four-detector row helical CT: Prospective evaluation of 216 outpatients and inpatients
    • Revel MP, Petrover D., Hernigou A., Lefort C., Meyer G., Frija G. Diagnosing pulmonary embolism with four-detector row helical CT: prospective evaluation of 216 outpatients and inpatients. Radiology. 2005 ; 234 (1). 265-273.
    • (2005) Radiology , vol.234 , Issue.1 , pp. 265-273
    • Revel, M.P.1    Petrover, D.2    Hernigou, A.3    Lefort, C.4    Meyer, G.5    Frija, G.6
  • 6
    • 36048951084 scopus 로고    scopus 로고
    • CT venography vs ultrasound in the diagnosis of thromboembolic disease in patients with clinical suspicion of pulmonary embolism
    • Garcia-Bolado A., Del Cura JL CT venography vs ultrasound in the diagnosis of thromboembolic disease in patients with clinical suspicion of pulmonary embolism. Emerg Radiol. 2007 ; 14 (6). 403-409.
    • (2007) Emerg Radiol , vol.14 , Issue.6 , pp. 403-409
    • Garcia-Bolado, A.1    Del Cura, J.L.2
  • 7
    • 33744759644 scopus 로고    scopus 로고
    • CT lower extremity venography in suspected pulmonary embolism in the ED
    • Johnson JC, Brown MD, McCullough N., Smith S. CT lower extremity venography in suspected pulmonary embolism in the ED. Emerg Radiol. 2006 ; 12 (4). 160-163.
    • (2006) Emerg Radiol , vol.12 , Issue.4 , pp. 160-163
    • Johnson, J.C.1    Brown, M.D.2    McCullough, N.3    Smith, S.4
  • 8
    • 33745181143 scopus 로고    scopus 로고
    • Does multi-detector row CT pulmonary angiography reduce the incremental value of indirect CT venography compared with single-detector row CT pulmonary angiography
    • Ghaye B., Nchimi A., Noukoua CT, Dondelinger RF Does multi-detector row CT pulmonary angiography reduce the incremental value of indirect CT venography compared with single-detector row CT pulmonary angiography ? Radiology. 2006 ; 240 (1). 256-262.
    • (2006) Radiology , vol.240 , Issue.1 , pp. 256-262
    • Ghaye, B.1    Nchimi, A.2    Noukoua, C.T.3    Dondelinger, R.F.4
  • 9
    • 0035055641 scopus 로고    scopus 로고
    • Deep venous thrombosis with suspected pulmonary embolism: Detection with combined CT venography and pulmonary angiography
    • Loud PA, Katz DS, Bruce DA, Klippenstein DL, Grossman ZD Deep venous thrombosis with suspected pulmonary embolism: detection with combined CT venography and pulmonary angiography. Radiology. 2001 ; 219 (2). 498-502.
    • (2001) Radiology , vol.219 , Issue.2 , pp. 498-502
    • Loud, P.A.1    Katz, D.S.2    Bruce, D.A.3    Klippenstein, D.L.4    Grossman, Z.D.5
  • 10
    • 17744412384 scopus 로고    scopus 로고
    • Incremental lower extremity CT venography, a simplified approach for the diagnosis of phlebitis in patients with pulmonary embolism
    • Nicolas M., Debelle L., Laurent V., et al. Incremental lower extremity CT venography, a simplified approach for the diagnosis of phlebitis in patients with pulmonary embolism. J Radiol. 2001 ; 82 (3 pt 1). 251-256.
    • (2001) J Radiol , vol.82 , Issue.3 PART 1 , pp. 251-256
    • Nicolas, M.1    Debelle, L.2    Laurent, V.3
  • 11
    • 12344335062 scopus 로고    scopus 로고
    • Thromboembolic disease detection at indirect CT venography versus CT pulmonary angiography
    • Cham MD, Yankelevitz DF, Henschke CI Thromboembolic disease detection at indirect CT venography versus CT pulmonary angiography. Radiology. 2005 ; 234 (2). 591-594.
    • (2005) Radiology , vol.234 , Issue.2 , pp. 591-594
    • Cham, M.D.1    Yankelevitz, D.F.2    Henschke, C.I.3
  • 12
    • 0035081406 scopus 로고    scopus 로고
    • Using dual-detector helical CT angiography to detect deep venous thrombosis in patients with suspicion of pulmonary embolism: Diagnostic value and additional findings
    • Coche EE, Hamoir XL, Hammer FD, Hainaut P., Goffette PP Using dual-detector helical CT angiography to detect deep venous thrombosis in patients with suspicion of pulmonary embolism: diagnostic value and additional findings. AJR Am J Roentgenol. 2001 ; 176 (4). 1035-1039.
    • (2001) AJR Am J Roentgenol , vol.176 , Issue.4 , pp. 1035-1039
    • Coche, E.E.1    Hamoir, X.L.2    Hammer, F.D.3    Hainaut, P.4    Goffette, P.P.5
  • 13
    • 0036713713 scopus 로고    scopus 로고
    • CT venographyand CT angiography of the pulmonary arteries in acute pulmonary embolism
    • Jonetz-Mentzel L., Eger C., Basche S. CT venographyand CT angiography of the pulmonary arteries in acute pulmonary embolism. Zentralbl Chir. 2002 ; 127 (9). 755-759.
    • (2002) Zentralbl Chir , vol.127 , Issue.9 , pp. 755-759
    • Jonetz-Mentzel, L.1    Eger, C.2    Basche, S.3
  • 14
    • 0033845844 scopus 로고    scopus 로고
    • Deep venous thrombosis: Detection by using indirect CT venography. The Pulmonary Angiography-Indirect CT Venography Cooperative Group
    • Cham MD, Yankelevitz DF, Shaham D., et al. Deep venous thrombosis: detection by using indirect CT venography. The Pulmonary Angiography-Indirect CT Venography Cooperative Group. Radiology. 2000 ; 216 (3). 744-751.
    • (2000) Radiology , vol.216 , Issue.3 , pp. 744-751
    • Cham, M.D.1    Yankelevitz, D.F.2    Shaham, D.3
  • 15
    • 34250729734 scopus 로고    scopus 로고
    • Benefit of CT venography for the diagnosis of thromboembolic disease
    • Rhee KH, Iyer RS, Cha S., et al. Benefit of CT venography for the diagnosis of thromboembolic disease. Clin Imaging. 2007 ; 31 (4). 253-258.
    • (2007) Clin Imaging , vol.31 , Issue.4 , pp. 253-258
    • Rhee, K.H.1    Iyer, R.S.2    Cha, S.3
  • 16
    • 34247131380 scopus 로고    scopus 로고
    • Incidence and distribution of lower extremity deep venous thrombosis at indirect computed tomography venography in patients suspected of pulmonary embolism
    • Nchimi A., Ghaye B., Noukoua CT, Dondelinger RF Incidence and distribution of lower extremity deep venous thrombosis at indirect computed tomography venography in patients suspected of pulmonary embolism. Thromb Haemost. 2007 ; 97 (4). 566-572.
    • (2007) Thromb Haemost , vol.97 , Issue.4 , pp. 566-572
    • Nchimi, A.1    Ghaye, B.2    Noukoua, C.T.3    Dondelinger, R.F.4
  • 17
    • 33845644987 scopus 로고    scopus 로고
    • Diagnostic pathways in acute pulmonary embolism: Recommendations of the PIOPED II investigators
    • (also published in Am J Med. 2006 ; 119: 1048-1055 )
    • Stein PD, Woodard PK, Weg JG, et al. Diagnostic pathways in acute pulmonary embolism: recommendations of the PIOPED II investigators. Radiology. 2007 ; 242 (1). 15-21 (also published in Am J Med. 2006 ; 119: 1048-1055 ).
    • (2007) Radiology , vol.242 , Issue.1 , pp. 15-21
    • Stein, P.D.1    Woodard, P.K.2    Weg, J.G.3
  • 18
    • 0035902631 scopus 로고    scopus 로고
    • Excluding PE at the bedside without diagnostic imaging: Management of patients with suspected PE presenting to the emergency department by using a simple clinical model and D-dimer
    • Wells PS, Anderson DR, Rodger M., et al. Excluding PE at the bedside without diagnostic imaging: management of patients with suspected PE presenting to the emergency department by using a simple clinical model and D-dimer. Ann Intern Med. 2001 ; 135 (2). 98-107.
    • (2001) Ann Intern Med , vol.135 , Issue.2 , pp. 98-107
    • Wells, P.S.1    Anderson, D.R.2    Rodger, M.3
  • 19
    • 35349026173 scopus 로고    scopus 로고
    • Management of suspected acute pulmonary embolism in the era of CT angiography: A statement of the Fleischner Society
    • Remy-Jardin M., Pistolesi M., Goodman LR, et al. Management of suspected acute pulmonary embolism in the era of CT angiography: a statement of the Fleischner Society. Radiology. 2007 ; 245 (2). 315-329.
    • (2007) Radiology , vol.245 , Issue.2 , pp. 315-329
    • Remy-Jardin, M.1    Pistolesi, M.2    Goodman, L.R.3
  • 20
    • 0037741054 scopus 로고    scopus 로고
    • Evaluation of the deep venous system in patients with suspected pulmonary embolism with multi-detector CT: A prospective study in comparison to Doppler sonography
    • Begemann PG, Bonacker M., Kemper J., et al. Evaluation of the deep venous system in patients with suspected pulmonary embolism with multi-detector CT: a prospective study in comparison to Doppler sonography. J Comput Assist Tomogr. 2003 ; 27 (3). 399-409.
    • (2003) J Comput Assist Tomogr , vol.27 , Issue.3 , pp. 399-409
    • Begemann, P.G.1    Bonacker, M.2    Kemper, J.3
  • 21
    • 0033797103 scopus 로고    scopus 로고
    • Thromboembolic disease: Comparison of combined CT pulmonary angiography and venography with bilateral leg sonography in 70 patients
    • Garg K., Kemp JL, Wojcik D., et al. Thromboembolic disease: comparison of combined CT pulmonary angiography and venography with bilateral leg sonography in 70 patients. AJR Am J Roentgenol. 2000 ; 175 (4). 997-1001.
    • (2000) AJR Am J Roentgenol , vol.175 , Issue.4 , pp. 997-1001
    • Garg, K.1    Kemp, J.L.2    Wojcik, D.3
  • 22
    • 20244387564 scopus 로고    scopus 로고
    • Multidetector-row computed tomography in suspected pulmonary embolism
    • Perrier A., Roy PM, Sanchez O., et al. Multidetector-row computed tomography in suspected pulmonary embolism. N Engl J Med. 2005 ; 352 (17). 1760-1768.
    • (2005) N Engl J Med , vol.352 , Issue.17 , pp. 1760-1768
    • Perrier, A.1    Roy, P.M.2    Sanchez, O.3
  • 23
    • 0037452502 scopus 로고    scopus 로고
    • Single-detector helical computed tomography as the primary diagnostic test in suspected pulmonary embolism: A multicenter clinical management study of 510 patients
    • the Advances in New Technologies Evaluating the Localisation of Pulmonary Embolism Study Group
    • van Strijen MJ, de Monyé W., Schiereck J., et al, for the Advances in New Technologies Evaluating the Localisation of Pulmonary Embolism Study Group. Single-detector helical computed tomography as the primary diagnostic test in suspected pulmonary embolism: a multicenter clinical management study of 510 patients. Ann Intern Med. 2003 ; 138 (4). 307-314.
    • (2003) Ann Intern Med , vol.138 , Issue.4 , pp. 307-314
    • Van Strijen, M.J.1    De Monyé, W.2    Schiereck, J.3
  • 24
    • 0037079361 scopus 로고    scopus 로고
    • Diagnostic strategy for patients with suspected pulmonary embolism: A prospective multicentre outcome study
    • Musset D., Parent F., Meyer G., et al. Diagnostic strategy for patients with suspected pulmonary embolism: a prospective multicentre outcome study. Lancet. 2002 ; 360 (9349). 1914-1920.
    • (2002) Lancet , vol.360 , Issue.9349 , pp. 1914-1920
    • Musset, D.1    Parent, F.2    Meyer, G.3
  • 25
    • 27144440472 scopus 로고    scopus 로고
    • Use of spiral computed tomography contrast angiography and ultrasonography to exclude the diagnosis of pulmonary embolism in the emergency department
    • Anderson DR, Kovacs MJ, Dennie C., et al. Use of spiral computed tomography contrast angiography and ultrasonography to exclude the diagnosis of pulmonary embolism in the emergency department. J Emerg Med. 2005 ; 29 (4). 399-404.
    • (2005) J Emerg Med , vol.29 , Issue.4 , pp. 399-404
    • Anderson, D.R.1    Kovacs, M.J.2    Dennie, C.3
  • 26
    • 35649003088 scopus 로고    scopus 로고
    • CT Venography and compression ultrasound are diagnostically equivalent: Data from PIOPED II
    • Goodman LR, Stein PD, Matta F., et al. CT Venography and compression ultrasound are diagnostically equivalent: data from PIOPED II. AJR Am J Roentgenol. 2007 ; 189 (5). 1071-1076.
    • (2007) AJR Am J Roentgenol , vol.189 , Issue.5 , pp. 1071-1076
    • Goodman, L.R.1    Stein, P.D.2    Matta, F.3
  • 27
    • 42049095662 scopus 로고    scopus 로고
    • Diagnosis of pulmonary embolism by multidetector CT alone or combined with venous ultrasonography of the leg: A randomised non-inferiority trial
    • Righini M., Le Gal G., Aujesky D., et al. Diagnosis of pulmonary embolism by multidetector CT alone or combined with venous ultrasonography of the leg: a randomised non-inferiority trial. Lancet. 2008 ; 371 (9621). 1343-1352.
    • (2008) Lancet , vol.371 , Issue.9621 , pp. 1343-1352
    • Righini, M.1    Le Gal, G.2    Aujesky, D.3
  • 28
    • 34447558140 scopus 로고    scopus 로고
    • Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
    • Einstein AJ, Henzlova MJ, Rajagopalan S. Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA. 2007 ; 298 (3). 317-323.
    • (2007) JAMA , vol.298 , Issue.3 , pp. 317-323
    • Einstein, A.J.1    Henzlova, M.J.2    Rajagopalan, S.3
  • 29
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography-an increasing source of radiation exposure
    • Brenner DJ, Hall EJ Computed tomography-an increasing source of radiation exposure. N Eng J Med. 2007 ; 357 (22). 2277-2284.
    • (2007) N Eng J Med , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 30
    • 39549118895 scopus 로고    scopus 로고
    • Computed tomography and radiation exposure
    • Tubiana M. Computed tomography and radiation exposure. N Engl J Med. 2008 ; 358 (8). 850.
    • (2008) N Engl J Med , vol.358 , Issue.8 , pp. 850
    • Tubiana, M.1
  • 31
    • 34547559527 scopus 로고    scopus 로고
    • CT venography: Continuous helical images versus reformatted discontinuous images using PIOPED II data
    • Goodman LR, Stein PD, Beemath A., et al. CT venography: continuous helical images versus reformatted discontinuous images using PIOPED II data. AJR Am J Roentgenol. 2007 ; 189 (2). 409-412.
    • (2007) AJR Am J Roentgenol , vol.189 , Issue.2 , pp. 409-412
    • Goodman, L.R.1    Stein, P.D.2    Beemath, A.3
  • 32
    • 25644449687 scopus 로고    scopus 로고
    • Prospective comparison of indirect CT venography versus venous sonography in ICU patients
    • Taffoni MJ, Ravenel JG, Ackerman SJ Prospective comparison of indirect CT venography versus venous sonography in ICU patients. AJR Am J Roentgenol. 2005 ; 185 (2). 457-462.
    • (2005) AJR Am J Roentgenol , vol.185 , Issue.2 , pp. 457-462
    • Taffoni, M.J.1    Ravenel, J.G.2    Ackerman, S.J.3
  • 33
    • 30444431617 scopus 로고    scopus 로고
    • Effectiveness of managing suspected pulmonary embolism using an algorithm combining clinical probability, D-dimer testing, and computed tomography
    • the Christopher Study Investigators
    • van Belle A., Büller HR, Huisman MV, et al, for the Christopher Study Investigators. Effectiveness of managing suspected pulmonary embolism using an algorithm combining clinical probability, D-dimer testing, and computed tomography. JAMA. 2006 ; 295 (2). 172-179.
    • (2006) JAMA , vol.295 , Issue.2 , pp. 172-179
    • Van Belle, A.1    Büller, H.R.2    Huisman, M.V.3
  • 34
    • 0028934975 scopus 로고
    • Untreated patients with pulmonary embolism: Outcome, clinical and laboratory assessment
    • Stein PD, Henry JW, Relyea B. Untreated patients with pulmonary embolism: outcome, clinical and laboratory assessment. Chest. 1995 ; 107 (4). 931-935.
    • (1995) Chest , vol.107 , Issue.4 , pp. 931-935
    • Stein, P.D.1    Henry, J.W.2    Relyea, B.3
  • 35
    • 33747086864 scopus 로고    scopus 로고
    • Outcome studies of pulmonary embolism versus accuracy: They do not equate
    • Stein PD, Beemath A., Goodman LR, et al. Outcome studies of pulmonary embolism versus accuracy: they do not equate. Thromb Haemost. 2006 ; 96 (2). 107-108.
    • (2006) Thromb Haemost , vol.96 , Issue.2 , pp. 107-108
    • Stein, P.D.1    Beemath, A.2    Goodman, L.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.