메뉴 건너뛰기




Volumn 53, Issue 8, 2010, Pages 1048-1058

Critical heat stress evaluation of clothing ensembles with different levels of porosity

Author keywords

Clothing; Convection; Diffusion; Evaporative resistance; Heat stress; WBGT

Indexed keywords

AIR FLOW; ASSESSMENT MEASURES; CONVECTION DIFFUSION; CONVECTIVE TRANSFER; DIFFUSION OF WATER; DOMINANT MECHANISM; EVAPORATIVE COOLING; HEAT STRESS; SARATOGA; SIMILAR PATTERN; SURFACE AREA; WATER VAPOUR; WET-BULB;

EID: 77954847419     PISSN: 00140139     EISSN: 13665847     Source Type: Journal    
DOI: 10.1080/00140139.2010.494736     Document Type: Article
Times cited : (27)

References (19)
  • 2
    • 45849136352 scopus 로고    scopus 로고
    • Heat strain at the critical WBGT and the roles of clothing, metabolic rate and gender
    • Ashley, C.D., et al., 2008. Heat strain at the critical WBGT and the roles of clothing, metabolic rate and gender. International Journal of Industrial Ergonomics, 38, 640-644.
    • (2008) International Journal of Industrial Ergonomics , vol.38 , pp. 640-644
    • Ashley, C.D.1
  • 3
    • 0004077698 scopus 로고    scopus 로고
    • American Society for Testing and Materials, Conshohocken, PA: ASTM
    • American Society for Testing and Materials, 2002. Annual book of ASTM standards -Part 11.03. Conshohocken, PA: ASTM.
    • (2002) Annual Book of ASTM Standards -Part 11.03
  • 4
    • 0141987151 scopus 로고    scopus 로고
    • American Society for Testing and Materials, Conshohocken, PA: ASTM
    • American Society for Testing and Materials, 2006. Annual book of ASTM standards -Part 7.01. Conshohocken, PA: ASTM.
    • (2006) Annual Book of ASTM Standards -Part 7.01
  • 6
    • 0015792794 scopus 로고
    • Evaporative coefficients for the prediction of safe limits in prolonged exposures to work under hot conditions
    • Belding, H.S. and Kamon, E., 1973. Evaporative coefficients for the prediction of safe limits in prolonged exposures to work under hot conditions. Federal Proceedings, 32, 1598-1601.
    • (1973) Federal Proceedings , vol.32 , pp. 1598-1601
    • Belding, H.S.1    Kamon, E.2
  • 7
    • 17844407138 scopus 로고    scopus 로고
    • WBGT clothing adjustment factors for four clothing ensembles under three humidity levels
    • Bernard, T.E., et al., 2005. WBGT clothing adjustment factors for four clothing ensembles under three humidity levels. Journal of Environmental and Occupational Hygiene, 2, 251-256.
    • (2005) Journal of Environmental and Occupational Hygiene , vol.2 , pp. 251-256
    • Bernard, T.E.1
  • 8
    • 40449135767 scopus 로고    scopus 로고
    • WBGT clothing adjustment factors for four clothing ensembles and the effects of metabolic demands
    • Bernard, T.E., et al., 2008. WBGT clothing adjustment factors for four clothing ensembles and the effects of metabolic demands. Journal of Environmental and Occupational Hygiene, 5, 1-5.
    • (2008) Journal of Environmental and Occupational Hygiene , vol.5 , pp. 1-5
    • Bernard, T.E.1
  • 9
    • 50449087634 scopus 로고    scopus 로고
    • Non-evaporative effects of a wet mid layer on heat transfer through protective clothing
    • Brode, P., et al., 2008. Non-evaporative effects of a wet mid layer on heat transfer through protective clothing. European Journal of Applied Physiology, 104, 341-349.
    • (2008) European Journal of Applied Physiology , vol.104 , pp. 341-349
    • Brode, P.1
  • 10
    • 50449099605 scopus 로고    scopus 로고
    • Apparent evaporative resistance at critical conditions for five clothing ensembles
    • Caravello, V., et al., 2008. Apparent evaporative resistance at critical conditions for five clothing ensembles. European Journal of Applied Physiology, 104, 361-367.
    • (2008) European Journal of Applied Physiology , vol.104 , pp. 361-367
    • Caravello, V.1
  • 11
    • 0344780068 scopus 로고
    • Report TR-95/032. Natick, MA: Natick Research, Development and Engineering Center, US Army Soldier Systems Command
    • Gibson, P., et al., 1995. An automated dynamic vapor permeation test method. Report TR-95/032. Natick, MA: Natick Research, Development and Engineering Center, US Army Soldier Systems Command.
    • (1995) An Automated Dynamic Vapor Permeation Test Method
    • Gibson, P.1
  • 12
    • 33645454729 scopus 로고    scopus 로고
    • Maximum sustainable work rate for five protective clothing ensembles with respect to moisture vapor transmission rate and air permeability
    • Gonzalez, N.W., et al., 2006. Maximum sustainable work rate for five protective clothing ensembles with respect to moisture vapor transmission rate and air permeability. Journal of Occupational and Environmental Hygiene, 3, 80-86.
    • (2006) Journal of Occupational and Environmental Hygiene , vol.3 , pp. 80-86
    • Gonzalez, N.W.1
  • 14
    • 6344229897 scopus 로고    scopus 로고
    • Correction of clothing insulation for movement and wind effects, a meta-analysis
    • Havenith, G. and Nilsson, H., 2004. Correction of clothing insulation for movement and wind effects, a meta-analysis. European Journal of Applied Physiology, 92, 636-640.
    • (2004) European Journal of Applied Physiology , vol.92 , pp. 636-640
    • Havenith, G.1    Nilsson, H.2
  • 15
    • 0032774708 scopus 로고    scopus 로고
    • Clothing evaporative heat resistance -proposal for improved representation in standards and models
    • Havenith, G., et al., 1999. Clothing evaporative heat resistance -proposal for improved representation in standards and models. Annals of Occupational Hygiene, 43,339-346.
    • (1999) Annals of Occupational Hygiene , vol.43 , pp. 339-346
    • Havenith, G.1
  • 17
    • 0027407645 scopus 로고
    • Simultaneous derivation of clothing-specific heat exchange coefficients
    • Kenney, W.L., et al., 1993. Simultaneous derivation of clothing-specific heat exchange coefficients. Medicine and Science in Sports and Exercise, 25 (2), 283-289.
    • (1993) Medicine and Science In Sports and Exercise , vol.25 , Issue.2 , pp. 283-289
    • Kenney, W.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.