Influence of an impedance threshold valve on ventilation with supraglottic airway devices during cardiopulmonary resuscitation in a manikin

Author keywords

Advanced life support (ALS); Airway management; Cardiopulmonary resuscitation (CPR); Intubation; Respiration, artificial; Simultaneous compression ventilation CPR

Indexed keywords

AIRWAY; ARTICLE; ARTIFICIAL VENTILATION; AUDIOVISUAL EQUIPMENT; DEVICE; EDUCATIONAL TECHNOLOGY; EMERGENCY TREATMENT; FACE MASK; IMPEDANCE THRESHOLD VALVE; INTUBATION; LARYNGEAL MASK; MEDICAL INSTRUMENTATION; OXYGEN DELIVERY DEVICE; PRIORITY JOURNAL; RESUSCITATION; TIDAL VOLUME; TRAINING; VENTILATOR; AIRWAY RESISTANCE; BIOLOGICAL MODEL; COMPARATIVE STUDY; DEVICES; EQUIPMENT DESIGN; HEART ARREST; HUMAN; PHYSIOLOGY; REPRODUCIBILITY;

EID: 77954762037     PISSN: 03009572     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2010.03.022     Document Type: Article
Times cited : (8)

References (23)
  • 1
    • 28444490018 scopus 로고    scopus 로고
    • European Resuscitation Council guidelines for resuscitation 2005. Section 4. Adult advanced life support
    • Nolan J.P., Deakin C.D., Soar J., Böttiger B.W., Smith G. European Resuscitation Council guidelines for resuscitation 2005. Section 4. Adult advanced life support. Resuscitation 2005, 67:S39-S86.
    • (2005) Resuscitation , vol.67
    • Nolan, J.P.1    Deakin, C.D.2    Soar, J.3    Böttiger, B.W.4    Smith, G.5
  • 2
    • 0028959943 scopus 로고
    • Improving active compression-decompression cardiopulmonary resuscitation with an inspiratory impedance valve
    • Lurie K.G., Coffeen P., Shultz J., McKnite S., Detloff B., Mulligan K. Improving active compression-decompression cardiopulmonary resuscitation with an inspiratory impedance valve. Circulation 1995, 91:1629-1632.
    • (1995) Circulation , vol.91 , pp. 1629-1632
    • Lurie, K.G.1    Coffeen, P.2    Shultz, J.3    McKnite, S.4    Detloff, B.5    Mulligan, K.6
  • 4
    • 0031977042 scopus 로고    scopus 로고
    • Optimizing standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve
    • Lurie K.G., Mulligan K.A., McKnite S., Detloff B., Lindstrom P., Lindner K.H. Optimizing standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve. Chest 1998, 113:1084-1090.
    • (1998) Chest , vol.113 , pp. 1084-1090
    • Lurie, K.G.1    Mulligan, K.A.2    McKnite, S.3    Detloff, B.4    Lindstrom, P.5    Lindner, K.H.6
  • 5
    • 0034858508 scopus 로고    scopus 로고
    • Improving standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve in a porcine model of cardiac arrest
    • Lurie K.G., Voelckel W.G., Zielinski T., et al. Improving standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve in a porcine model of cardiac arrest. Anesth Analg 2001, 93:649-655.
    • (2001) Anesth Analg , vol.93 , pp. 649-655
    • Lurie, K.G.1    Voelckel, W.G.2    Zielinski, T.3
  • 6
    • 0036140750 scopus 로고    scopus 로고
    • Use of an inspiratory impedance valve improves neurologically intact survival in a porcine model of ventricular fibrillation
    • Lurie K.G., Zielinski T., McKnite S., Aufderheide T., Voelckel W. Use of an inspiratory impedance valve improves neurologically intact survival in a porcine model of ventricular fibrillation. Circulation 2002, 105:124-129.
    • (2002) Circulation , vol.105 , pp. 124-129
    • Lurie, K.G.1    Zielinski, T.2    McKnite, S.3    Aufderheide, T.4    Voelckel, W.5
  • 7
    • 1842738291 scopus 로고    scopus 로고
    • Reducing ventilation frequency combined with an inspiratory impedance device improves CPR efficiency in swine model of cardiac arrest
    • Yannopoulos D., Sigurdsson G., McKnite S., Benditt D., Lurie K.G. Reducing ventilation frequency combined with an inspiratory impedance device improves CPR efficiency in swine model of cardiac arrest. Resuscitation 2004, 61:75-82.
    • (2004) Resuscitation , vol.61 , pp. 75-82
    • Yannopoulos, D.1    Sigurdsson, G.2    McKnite, S.3    Benditt, D.4    Lurie, K.G.5
  • 8
    • 17044425083 scopus 로고    scopus 로고
    • Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest
    • Aufderheide T.P., Pirrallo R.G., Provo T.A., Lurie K.G. Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest. Crit Care Med 2005, 33:734-740.
    • (2005) Crit Care Med , vol.33 , pp. 734-740
    • Aufderheide, T.P.1    Pirrallo, R.G.2    Provo, T.A.3    Lurie, K.G.4
  • 9
    • 21544463161 scopus 로고    scopus 로고
    • Effect of an inspiratory impedance threshold device on hemodynamics during conventional manual cardiopulmonary resuscitation
    • Pirrallo R.G., Aufderheide T.P., Provo T.A., Lurie K.G. Effect of an inspiratory impedance threshold device on hemodynamics during conventional manual cardiopulmonary resuscitation. Resuscitation 2005, 66:13-20.
    • (2005) Resuscitation , vol.66 , pp. 13-20
    • Pirrallo, R.G.1    Aufderheide, T.P.2    Provo, T.A.3    Lurie, K.G.4
  • 10
    • 0034007187 scopus 로고    scopus 로고
    • Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation: a randomized evaluation in patients in cardiac arrest
    • Plaisance P., Lurie K.G., Payen D. Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation: a randomized evaluation in patients in cardiac arrest. Circulation 2000, 101:989-994.
    • (2000) Circulation , vol.101 , pp. 989-994
    • Plaisance, P.1    Lurie, K.G.2    Payen, D.3
  • 11
    • 2542456619 scopus 로고    scopus 로고
    • Evaluation of an impedance threshold device in patients receiving active compression-decompression cardiopulmonary resuscitation for out of hospital cardiac arrest
    • Plaisance P., Lurie K.G., Vicaut E., et al. Evaluation of an impedance threshold device in patients receiving active compression-decompression cardiopulmonary resuscitation for out of hospital cardiac arrest. Resuscitation 2004, 61:265-271.
    • (2004) Resuscitation , vol.61 , pp. 265-271
    • Plaisance, P.1    Lurie, K.G.2    Vicaut, E.3
  • 12
    • 0242361648 scopus 로고    scopus 로고
    • Comparison of standard cardiopulmonary resuscitation versus the combination of active compression-decompression cardiopulmonary resuscitation and an inspiratory impedance threshold device for out-of-hospital cardiac arrest
    • Wolcke B.B., Mauer D.K., Schoefmann M.F., et al. Comparison of standard cardiopulmonary resuscitation versus the combination of active compression-decompression cardiopulmonary resuscitation and an inspiratory impedance threshold device for out-of-hospital cardiac arrest. Circulation 2003, 108:2201-2205.
    • (2003) Circulation , vol.108 , pp. 2201-2205
    • Wolcke, B.B.1    Mauer, D.K.2    Schoefmann, M.F.3
  • 13
    • 18344379407 scopus 로고    scopus 로고
    • Use of an inspiratory impedance threshold device on a facemask and endotracheal tube to reduce intrathoracic pressures during the decompression phase of active compression-decompression cardiopulmonary resuscitation
    • Plaisance P., Soleil C., Lurie K.G., Vicaut E., Ducros L., Payen D. Use of an inspiratory impedance threshold device on a facemask and endotracheal tube to reduce intrathoracic pressures during the decompression phase of active compression-decompression cardiopulmonary resuscitation. Crit Care Med 2005, 33:990-994.
    • (2005) Crit Care Med , vol.33 , pp. 990-994
    • Plaisance, P.1    Soleil, C.2    Lurie, K.G.3    Vicaut, E.4    Ducros, L.5    Payen, D.6
  • 14
    • 34347380183 scopus 로고    scopus 로고
    • Two rescuer resuscitation - mission impossible? A pilot study using a manikin setting
    • Brucke M., Helm M., Schwartz A., Lampl L. Two rescuer resuscitation - mission impossible? A pilot study using a manikin setting. Resuscitation 2007, 74:317-324.
    • (2007) Resuscitation , vol.74 , pp. 317-324
    • Brucke, M.1    Helm, M.2    Schwartz, A.3    Lampl, L.4
  • 15
    • 0035662387 scopus 로고    scopus 로고
    • Assessment of the use of the laryngeal tube for cardiopulmonary resuscitation in a manikin
    • Genzwuerker H.V., Finteis T., Slabschi D., Groeschel J., Ellinger K. Assessment of the use of the laryngeal tube for cardiopulmonary resuscitation in a manikin. Resuscitation 2001, 51:291-296.
    • (2001) Resuscitation , vol.51 , pp. 291-296
    • Genzwuerker, H.V.1    Finteis, T.2    Slabschi, D.3    Groeschel, J.4    Ellinger, K.5
  • 18
    • 34249025432 scopus 로고    scopus 로고
    • The impedance threshold valve for adult cardiopulmonary resuscitation: a review of the literature
    • Pirracchio R., Payen D., Plaisance P. The impedance threshold valve for adult cardiopulmonary resuscitation: a review of the literature. Curr Opin Crit Care 2007, 13:280-286.
    • (2007) Curr Opin Crit Care , vol.13 , pp. 280-286
    • Pirracchio, R.1    Payen, D.2    Plaisance, P.3
  • 19
    • 28544432407 scopus 로고    scopus 로고
    • European Resuscitation Council Guidelines for resuscitation 2005. Section 2. Adult basic life support and use of automated external defibrillators
    • Handley A.J., Koster R., Monsieurs K., Perkins G.D., Davies S., Bossaert L. European Resuscitation Council Guidelines for resuscitation 2005. Section 2. Adult basic life support and use of automated external defibrillators. Resuscitation 2005, 67:S7-S23.
    • (2005) Resuscitation , vol.67
    • Handley, A.J.1    Koster, R.2    Monsieurs, K.3    Perkins, G.D.4    Davies, S.5    Bossaert, L.6
  • 20
    • 33847332688 scopus 로고    scopus 로고
    • Use of an inspiratory impedance threshold valve during chest compressions without assisted ventilation may result in hypoxaemia
    • Herff H., Raedler C., Zander R., et al. Use of an inspiratory impedance threshold valve during chest compressions without assisted ventilation may result in hypoxaemia. Resuscitation 2007, 72:466-476.
    • (2007) Resuscitation , vol.72 , pp. 466-476
    • Herff, H.1    Raedler, C.2    Zander, R.3
  • 21
    • 33947519698 scopus 로고    scopus 로고
    • Imposed power of breathing associated with use of an impedance threshold device
    • Idris A.H., Convertino V.A., Ratliff D.A., et al. Imposed power of breathing associated with use of an impedance threshold device. Respir Care 2007, 52:177-183.
    • (2007) Respir Care , vol.52 , pp. 177-183
    • Idris, A.H.1    Convertino, V.A.2    Ratliff, D.A.3
  • 22
    • 38549181011 scopus 로고    scopus 로고
    • A comparison of seal in seven supraglottic airway devices using a cadaver model of elevated esophageal pressure
    • Bercker S., Schmidbauer W., Volk T., et al. A comparison of seal in seven supraglottic airway devices using a cadaver model of elevated esophageal pressure. Anesth Analg 2008, 106:445-448.
    • (2008) Anesth Analg , vol.106 , pp. 445-448
    • Bercker, S.1    Schmidbauer, W.2    Volk, T.3
  • 23
    • 57349166088 scopus 로고    scopus 로고
    • Oesophageal seal of the novel supralaryngeal airway device I-Gel in comparison with the laryngeal mask airways Classic and ProSeal using a cadaver model
    • Schmidbauer W., Bercker S., Volk T., Bogusch G., Mager G., Kerner T. Oesophageal seal of the novel supralaryngeal airway device I-Gel in comparison with the laryngeal mask airways Classic and ProSeal using a cadaver model. Br J Anaesth 2009, 102:135-139.
    • (2009) Br J Anaesth , vol.102 , pp. 135-139
    • Schmidbauer, W.1    Bercker, S.2    Volk, T.3    Bogusch, G.4    Mager, G.5    Kerner, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.