메뉴 건너뛰기




Volumn 6136 LNCS, Issue , 2010, Pages 598-605

Breast structural noise in digital breast tomosynthesis and its dependence on reconstruction methods

Author keywords

anatomical clutter; digital breast tomosynthesis; ideal observer model; linear system model; NPS

Indexed keywords

BREAST LESION DETECTION; BREAST STRUCTURE; BREAST TISSUES; CASCADED LINEAR SYSTEMS; DATA SETS; DIGITAL BREAST TOMOSYNTHESIS; FILTERED BACK PROJECTION; IDEAL OBSERVERS; LINEAR SYSTEM MODEL; POWER LAW EXPONENT; POWER-LAW NOISE; RECONSTRUCTION ALGORITHMS; RECONSTRUCTION METHOD; RECONSTRUCTION PROCESS; STRUCTURAL NOISE;

EID: 77954652817     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-642-13666-5_81     Document Type: Conference Paper
Times cited : (12)

References (9)
  • 1
    • 0032593780 scopus 로고    scopus 로고
    • Mammographic Structure: Data Preparation and Spatial Statistics Analysis
    • Burgess, A.E.: Mammographic Structure: Data Preparation and Spatial Statistics Analysis. Med. Imag. 1999: Image Processing 3661, 642-653 (1999)
    • (1999) Med. Imag. 1999: Image Processing , vol.3661 , pp. 642-653
    • Burgess, A.E.1
  • 2
    • 52949134073 scopus 로고    scopus 로고
    • Characterizing Anatomical Variability in Breast CT Images
    • Metheany, K.G., Abbey, C.K., Packard, N., Boone, J.M.: Characterizing Anatomical Variability in Breast CT Images. Med. Phys. 35(10), 4685-4694 (2008)
    • (2008) Med. Phys. , vol.35 , Issue.10 , pp. 4685-4694
    • Metheany, K.G.1    Abbey, C.K.2    Packard, N.3    Boone, J.M.4
  • 3
    • 65449139477 scopus 로고    scopus 로고
    • Comparison of Power Spectra for Tomosynthesis Projections and Reconstructed Images
    • Engstrom, E., Reiser, I., Nishikawa, R.: Comparison of Power Spectra for Tomosynthesis Projections and Reconstructed Images. Med. Phys. 36(5), 1753-1758 (2009)
    • (2009) Med. Phys. , vol.36 , Issue.5 , pp. 1753-1758
    • Engstrom, E.1    Reiser, I.2    Nishikawa, R.3
  • 4
    • 66749109447 scopus 로고    scopus 로고
    • Nonuniform Angular Dose Distribution in Digital Breast Tomosynthesis for Increased Conspicuity of Small High Contrast Objects
    • Hu, Y.-H., Zhao, W.: Nonuniform Angular Dose Distribution in Digital Breast Tomosynthesis for Increased Conspicuity of Small High Contrast Objects. Med. Imag. 2009: Physics of Medical Imaging 7258, 72580Q1-72580Q8 (2009)
    • (2009) Med. Imag. 2009: Physics of Medical Imaging , vol.7258
    • Hu, Y.-H.1    Zhao, W.2
  • 6
    • 0005642443 scopus 로고    scopus 로고
    • A Theoretical Framework for Filtered Backprojection in Tomosynthesis
    • Lauritsch, G., Harer, W.H.: A Theoretical Framework for Filtered Backprojection in Tomosynthesis. Med. Imag. 1998: Image Processing 3338, 1127-1137 (1998)
    • (1998) Med. Imag. 1998: Image Processing , vol.3338 , pp. 1127-1137
    • Lauritsch, G.1    Harer, W.H.2
  • 7
    • 50949118673 scopus 로고    scopus 로고
    • A Novel Approach for Filtered Backprojection in Tomosynthesis Based on Filtered Kernels Determined by Iterative Reconstruction Techniques
    • Krupinski, E.A. (ed.) IWDM 2008. Springer, Heidelberg
    • Ludwig, J., Mertelmeier, T., Kunze, H., Harer, W.: A Novel Approach for Filtered Backprojection in Tomosynthesis Based on Filtered Kernels Determined by Iterative Reconstruction Techniques. In: Krupinski, E.A. (ed.) IWDM 2008. LNCS, vol. 5116, pp. 612-620. Springer, Heidelberg (2008)
    • (2008) LNCS , vol.5116 , pp. 612-620
    • Ludwig, J.1    Mertelmeier, T.2    Kunze, H.3    Harer, W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.