메뉴 건너뛰기




Volumn 6136 LNCS, Issue , 2010, Pages 452-458

An anthropomorphic software breast phantom for tomosynthesis simulation: Power spectrum analysis of phantom projections

Author keywords

breast anthropomorphic phantom; digital breast tomosynthesis; power law; power spectrum

Indexed keywords

2-D FFT; ANTHROPOMORPHIC PHANTOMS; BREAST PHANTOM; CLINICAL IMAGES; DIGITAL BREAST TOMOSYNTHESIS; MAMMOGRAPHIC; MONOENERGETIC; PERIODOGRAMS; POWER-LAW POWER SPECTRA; SPECTRAL ANALYSIS; SPECTRAL POWER; TOMOSYNTHESIS;

EID: 77954634065     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-642-13666-5_61     Document Type: Conference Paper
Times cited : (11)

References (7)
  • 1
    • 0035049369 scopus 로고    scopus 로고
    • Human observer detection experiments with mammograms and power-law noise
    • Burgess, A.E., Jacobson, F.L., Judy, P.F.: Human observer detection experiments with mammograms and power-law noise. Medical physics 28, 419-437 (2001)
    • (2001) Medical Physics , vol.28 , pp. 419-437
    • Burgess, A.E.1    Jacobson, F.L.2    Judy, P.F.3
  • 2
    • 0032593780 scopus 로고    scopus 로고
    • Mammographic structure: Data preparation and spatial statistics analysis
    • Burgess, A.E.: Mammographic structure: data preparation and spatial statistics analysis. In: Proc. SPIE, vol. 3661, pp. 642-653 (1999)
    • (1999) Proc. SPIE , vol.3661 , pp. 642-653
    • Burgess, A.E.1
  • 3
    • 65449139477 scopus 로고    scopus 로고
    • Comparison of power spectra for tomosynthesis projections and reconstructed images
    • Engstrom, E., Reiser, I., Nishikawa, R.: Comparison of power spectra for tomosynthesis projections and reconstructed images. Medical Physics 36, 1753-1758 (2009)
    • (2009) Medical Physics , vol.36 , pp. 1753-1758
    • Engstrom, E.1    Reiser, I.2    Nishikawa, R.3
  • 4
    • 0036734336 scopus 로고    scopus 로고
    • Mammogram synthesis using a 3D simulation. I. Breast tissue model and image acquisition simulation
    • Bakic, P.R., Albert, M., Brzakovic, D., Maidment, A.D.A.: Mammogram synthesis using a 3D simulation. I. Breast tissue model and image acquisition simulation. Medical Physics 29, 2131-2139 (2002)
    • (2002) Medical Physics , vol.29 , pp. 2131-2139
    • Bakic, P.R.1    Albert, M.2    Brzakovic, D.3    Maidment, A.D.A.4
  • 6
    • 4644334876 scopus 로고    scopus 로고
    • A comparison of reconstruction algorithms for breast tomosynthesis
    • DOI 10.1118/1.1786692
    • Wu, T., Moore, R., Rafferty, E., Kopans, D.: A comparison of reconstruction algorithms for breast tomosynthesis. Medical Physics 31, 2636-2647 (2004) (Pubitemid 39287881)
    • (2004) Medical Physics , vol.31 , Issue.9 , pp. 2636-2647
    • Wu, T.1    Moore, R.H.2    Rafferty, E.A.3    Kopans, D.B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.