메뉴 건너뛰기




Volumn 6136 LNCS, Issue , 2010, Pages 78-85

Validation of a simulated dose reduction methodology using digital mammography CDMAM images and mastectomy images

Author keywords

CDMAM phantom; Digital mammography; dose reduction; mastectomy; simulation; validation

Indexed keywords

CDMAM PHANTOM; CONTRAST-DETAIL CURVE; DIGITAL MAMMOGRAPHY; DIGITAL MAMMOGRAPHY SYSTEM; DOSE LEVELS; DOSE REDUCTION; FILTERED NOISE; HIGH DOSE; HIGH SPATIAL FREQUENCY; LOW DOSE; NOISE-POWER SPECTRA; SIMULATION VALIDATION;

EID: 77954630951     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-642-13666-5_11     Document Type: Conference Paper
Times cited : (3)

References (12)
  • 1
    • 34247532299 scopus 로고    scopus 로고
    • Digital mammography: Effects of reduced radiation dose on diagnostic performance
    • DOI 10.1148/radiol.2432061065
    • Samei, E., Saunders, R.S., Baker, J.A., Delong, D.M.: Digital Mammography: Effects of Reduced Radiation Dose on Diagnostic Performance. Radiology 243(2), 396-404 (2007) (Pubitemid 46649694)
    • (2007) Radiology , vol.243 , Issue.2 , pp. 396-404
    • Samei, E.1    Saunders Jr., R.S.2    Baker, J.A.3    Delong, D.M.4
  • 3
    • 0041461316 scopus 로고    scopus 로고
    • A method for modifying the image quality parameters of digital radiographic images
    • Saunders, R.S., Samei, E.: A method for modifying the image quality parameters of digital radiographic images. Med. Phys. 30(11), 3006-3017 (2003)
    • (2003) Med. Phys. , vol.30 , Issue.11 , pp. 3006-3017
    • Saunders, R.S.1    Samei, E.2
  • 4
    • 23844549288 scopus 로고    scopus 로고
    • Simulation of Digital Mammography
    • Flynn, M.J. (ed.) SPIE
    • Workman, A.: Simulation of Digital Mammography. In: Flynn, M.J. (ed.) Medical Imaging 2005: Physics of Medical Imaging. SPIE, vol. 5745, pp. 933-942 (2005)
    • (2005) Medical Imaging 2005: Physics of Medical Imaging , vol.5745 , pp. 933-942
    • Workman, A.1
  • 6
    • 33746354973 scopus 로고    scopus 로고
    • Impact of Textured Background on Scoring of Simulated CDMAM Phantom
    • Astley, S.M., Brady, M., Rose, C., Zwiggelaar, R. (eds.) IWDM 2006. Springer, Heidelberg
    • Grosjean, B., Muller, S.: Impact of Textured Background on Scoring of Simulated CDMAM Phantom. In: Astley, S.M., Brady, M., Rose, C., Zwiggelaar, R. (eds.) IWDM 2006. LNCS, vol. 4046, pp. 460-467. Springer, Heidelberg (2006)
    • (2006) LNCS , vol.4046 , pp. 460-467
    • Grosjean, B.1    Muller, S.2
  • 8
    • 0032783631 scopus 로고    scopus 로고
    • Estimation of the noisy component of anatomical backgrounds
    • Bochud, F.O., Valley, J.-F., Verdun, F.R.: Estimation of the noisy component of anatomical backgrounds. Med. Phys. 26(7), 1365-1370 (1999)
    • (1999) Med. Phys. , vol.26 , Issue.7 , pp. 1365-1370
    • Bochud, F.O.1    Valley, J.-F.2    Verdun, F.R.3
  • 9
    • 0032742627 scopus 로고    scopus 로고
    • On the statistical nature of mammograms
    • Heine, J.J.: On the statistical nature of mammograms. Med. Phys. 26(11), 2254-2265 (1999)
    • (1999) Med. Phys. , vol.26 , Issue.11 , pp. 2254-2265
    • Heine, J.J.1
  • 12
    • 33746376324 scopus 로고    scopus 로고
    • Automated and human determination of threshold contrast for digital mammography systems
    • Astley, S.M., Brady, M., Rose, C., Zwiggelaar, R. (eds.) IWDM 2006. Springer, Heidelberg
    • Young, K.C., Cook, J.J.H., Oduko, J.M.: Automated and human determination of threshold contrast for digital mammography systems. In: Astley, S.M., Brady, M., Rose, C., Zwiggelaar, R. (eds.) IWDM 2006. LNCS, vol. 4046, pp. 266-272. Springer, Heidelberg (2006)
    • (2006) LNCS , vol.4046 , pp. 266-272
    • Young, K.C.1    Cook, J.J.H.2    Oduko, J.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.