메뉴 건너뛰기




Volumn 11, Issue 1, 2010, Pages 46-51

Influence of lung mechanical properties and alveolar architecture on the pathogenesis of ischemia-reperfusion injury

Author keywords

Euro collins solution; Lung mechanics; Lung morphometry; Lung preservation

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; BREATHING MECHANICS; COLD ISCHEMIA; CONTROLLED STUDY; LUNG ALVEOLUS; LUNG EDEMA; LUNG FUNCTION; LUNG GAS EXCHANGE; LUNG HEMODYNAMICS; LUNG MECHANICS; LUNG STRUCTURE; LUNG VASCULAR RESISTANCE; MALE; MORPHOMETRICS; NONHUMAN; ORGAN PRESERVATION; PATHOGENESIS; PRIORITY JOURNAL; RAT; REPERFUSION INJURY; TIDAL VOLUME; TOTAL LUNG CAPACITY; AERATION; ANIMAL; ARTIFICIAL VENTILATION; LUNG; LUNG CIRCULATION; LUNG DISEASES; LUNG TRANSPLANTATION; PATHOLOGY; PATHOPHYSIOLOGY; POSITIVE END EXPIRATORY PRESSURE; PROCEDURES; PULMONARY EDEMA; REPERFUSION; SURGERY; TIME; VASCULARIZATION; WISTAR RAT;

EID: 77954561668     PISSN: 15699293     EISSN: None     Source Type: Journal    
DOI: 10.1510/icvts.2009.222018     Document Type: Article
Times cited : (12)

References (13)
  • 3
    • 0032702176 scopus 로고    scopus 로고
    • Alveolar recruitment prevents rapid-reperfusion induced injury of lung transplants
    • DeCampos KN, Keshavjee SH, Slutsky AS, Liu, M. Alveolar recruitment prevents rapid-reperfusion induced injury of lung transplants. J Heart Lung Transplant 1999; 18: 1096-1102.
    • (1999) J Heart Lung Transplant , vol.18 , pp. 1096-1102
    • Decampos, K.N.1    Keshavjee, S.H.2    Slutsky, A.S.3    Liu, M.4
  • 5
    • 0036089855 scopus 로고    scopus 로고
    • Effects of pulmonary vascular pressure and flow on airway and parenchymal mechanics in isolated rat lungs
    • Peták F, Habre W, Hantos Z, Sly PD, Morel DR. Effects of pulmonary vascular pressure and flow on airway and parenchymal mechanics in isolated rat lungs. J Appl Physiol 2002; 92: 169-178.
    • (2002) J Appl Physiol , vol.92 , pp. 169-178
    • Pétak, F.1    Habre, W.2    Hantos, Z.3    Sly, P.D.4    Morel, D.R.5
  • 7
    • 0029963295 scopus 로고    scopus 로고
    • Use of a hypoxic lung as a deoxygenator to provide extended assessment of pulmonary function in rats
    • DeCampos KN, Keshavjee SH, Tremblay L, Yamashiro T, Slutsky AS. Use of a hypoxic lung as a deoxygenator to provide extended assessment of pulmonary function in rats. J Appl Physiol 1996; 80: 1835-1840.
    • (1996) J Appl Physiol , vol.80 , pp. 1835-1840
    • Decampos, K.N.1    Keshavjee, S.H.2    Tremblay, L.3    Yamashiro, T.4    Slutsky, A.S.5
  • 9
    • 0020597235 scopus 로고
    • Two side-arm tracheal cannula for respiratory airflow measurements in small animals
    • Mortola JP, Noworaj A. Two side-arm tracheal cannula for respiratory airflow measurements in small animals. J Appl Physiol 1983; 55: 250-253.
    • (1983) J Appl Physiol , vol.55 , pp. 250-253
    • Mortola, J.P.1    Noworaj, A.2
  • 10
    • 0016167380 scopus 로고
    • Digital computer calculation of human pulmonary mechanics using a least squares fit technique
    • Uhl R, Lewis F. Digital computer calculation of human pulmonary mechanics using a least squares fit technique. Comput Biomed Res 1974; 7: 489-495.
    • (1974) Comput Biomed Res , vol.7 , pp. 489-495
    • Uhl, R.1    Lewis, F.2
  • 13
    • 0022256369 scopus 로고
    • Analysis of the behavior of the respiratory system with constant inspiratory flow
    • Bates JH, Rossi A, Milic-Emili J. Analysis of the behavior of the respiratory system with constant inspiratory flow. J Appl Physiol 1985; 58: 1840-1848.
    • (1985) J Appl Physiol , vol.58 , pp. 1840-1848
    • Bates, J.H.1    Rossi, A.2    Milic-Emili, J.3