Volumn 65, Issue 8, 2010, Pages 841-847

Manikin study of fibreoptic-guided intubation through the classic laryngeal mask airway with the Aintree intubating catheter vs the intubating laryngeal mask airway in the simulated difficult airway

Author keywords

[No Author keywords available]

Indexed keywords

AIRWAY; AIRWAY RESISTANCE; ANESTHESIST; ARTICLE; ASSISTED VENTILATION; AUDIOVISUAL EQUIPMENT; CATHETER; CONTROLLED STUDY; CROSSOVER PROCEDURE; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; FIBER OPTICS; FIBEROSCOPE; HUMAN; INTERMETHOD COMPARISON; LARYNGEAL MASK; SIMULATED DIFFICULT AIRWAY; TRACHEA; VOCAL CORD;

EID: 77954502277     PISSN: 00032409     EISSN: 13652044     Source Type: Journal    
DOI: 10.1111/j.1365-2044.2010.06412.x     Document Type: Article
Times cited : (20)

References (23)
  • 2
    • 0034768602 scopus 로고    scopus 로고
    • Use of the intubating LMA-Fastrach in 254 patients with difficult-to-manage airways
    • Ferson D, Rosenblatt W, Johansen M, Osborn I, Ovassapian O. Use of the intubating LMA-Fastrach in 254 patients with difficult-to-manage airways. Anesthesiology 2001 95 : 1175 1181.
    • (2001) Anesthesiology , vol.95 , pp. 1175-1181
    • Ferson, D.1    Rosenblatt, W.2    Johansen, M.3    Osborn, I.4    Ovassapian, O.5
  • 3
    • 3242884152 scopus 로고    scopus 로고
    • Difficult Airway Society guidelines for management of the unanticipated difficult intubation
    • Henderson JJ, Popat MT, Latto IP, Pearce AC. Difficult Airway Society guidelines for management of the unanticipated difficult intubation. Anaesthesia 2004 59 : 675 694.
    • (2004) Anaesthesia , vol.59 , pp. 675-694
    • Henderson, J.J.1    Popat, M.T.2    Latto, I.P.3    Pearce, A.C.4
  • 4
    • 34249014280 scopus 로고    scopus 로고
    • Fibreoptic intubation using three airway conduits in a manikin: The effect of operator experience
    • Hodzovic I, Petterson J, Wilkes AR, Latto IP. Fibreoptic intubation using three airway conduits in a manikin: the effect of operator experience. Anaesthesia 2007 62 : 591 597.
    • (2007) Anaesthesia , vol.62 , pp. 591-597
    • Hodzovic, I.1    Petterson, J.2    Wilkes, A.R.3    Latto, I.P.4
  • 5
    • 0027202276 scopus 로고
    • The distance between the grille of the laryngeal mask airway and the vocal cords. Is conventional intubation through the laryngeal mask safe?
    • Asai T, Latto IP, Vaughan RS. The distance between the grille of the laryngeal mask airway and the vocal cords. Is conventional intubation through the laryngeal mask safe?. Anaesthesia 1993 48 : 667 669.
    • (1993) Anaesthesia , vol.48 , pp. 667-669
    • Asai, T.1    Latto, I.P.2    Vaughan, R.S.3
  • 6
    • 0029768074 scopus 로고    scopus 로고
    • Laryngeal mask airway and the ASA difficult airway algorithm: I
    • Alfery D. Laryngeal mask airway and the ASA difficult airway algorithm: I. Anesthesiology 1996 85 : 685.
    • (1996) Anesthesiology , vol.85 , pp. 685
    • Alfery, D.1
  • 7
    • 0030476764 scopus 로고    scopus 로고
    • A ventilation-exchange bougie for fibreoptic intubations with the laryngeal mask airway
    • Atherton DPL, O'Sullivan E, Lowe D, Charters P. A ventilation-exchange bougie for fibreoptic intubations with the laryngeal mask airway. Anaesthesia 1996 51 : 1123 1126.
    • (1996) Anaesthesia , vol.51 , pp. 1123-1126
    • Atherton, D.P.L.1    O'Sullivan, E.2    Lowe, D.3    Charters, P.4
  • 8
    • 23844536471 scopus 로고    scopus 로고
    • Use of the Aintree intubation catheter in a patient with an unexpected difficult airway
    • Zura A, Doyle DJ, Orlandi M. Use of the Aintree intubation catheter in a patient with an unexpected difficult airway. Canadian Journal of Anesthesia 2005 52 : 646 649.
    • (2005) Canadian Journal of Anesthesia , vol.52 , pp. 646-649
    • Zura, A.1    Doyle, D.J.2    Orlandi, M.3
  • 9
    • 23944464466 scopus 로고    scopus 로고
    • Low-skill fibreoptic intubation: Use of the Aintree Catheter with the Classic LMA
    • Higgs A, Clark E, Premraj K. Low-skill fibreoptic intubation: use of the Aintree Catheter with the Classic LMA. Anaesthesia 2005 60 : 915 920.
    • (2005) Anaesthesia , vol.60 , pp. 915-920
    • Higgs, A.1    Clark, E.2    Premraj, K.3
  • 10
    • 2942659508 scopus 로고    scopus 로고
    • Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope: Incidence, causes and solutions
    • Asai T, Shingu K. Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope: incidence, causes and solutions. British Journal of Anaesthesia 2004 92 : 870 881.
    • (2004) British Journal of Anaesthesia , vol.92 , pp. 870-881
    • Asai, T.1    Shingu, K.2
  • 11
    • 33947654834 scopus 로고    scopus 로고
    • Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices
    • Jackson KM, Cook TM. Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices. Anaesthesia 2007 62 : 388 393.
    • (2007) Anaesthesia , vol.62 , pp. 388-393
    • Jackson, K.M.1    Cook, T.M.2
  • 12
    • 44949201037 scopus 로고    scopus 로고
    • Comparison of fibreoptic-guided intubation through ILMA versus intubation through LMA-Ctrach
    • Sreevathsa S, Linga Nathan P, John B, Danha RF, Mendoca C. Comparison of fibreoptic-guided intubation through ILMA versus intubation through LMA-Ctrach. Anaesthesia 2008 63 : 734 737.
    • (2008) Anaesthesia , vol.63 , pp. 734-737
    • Sreevathsa, S.1    Linga Nathan, P.2    John, B.3    Danha, R.F.4    Mendoca, C.5
  • 13
    • 0034939042 scopus 로고    scopus 로고
    • A manoeuvre for using the flexible fibreoptic bronchoscope through the Intubating Laryngeal Mask Airway
    • Panjwani S, Seymour P, Pandit JJ. A manoeuvre for using the flexible fibreoptic bronchoscope through the Intubating Laryngeal Mask Airway. Anaesthesia 2001 56 : 696 697.
    • (2001) Anaesthesia , vol.56 , pp. 696-697
    • Panjwani, S.1    Seymour, P.2    Pandit, J.J.3
  • 14
    • 77954499952 scopus 로고    scopus 로고
    • Clinical Human Factors Group. (accessed 24/01/20)
    • Clinical Human Factors Group. http://www.chfg.org (accessed 24/01/20).
  • 15
    • 0032955863 scopus 로고    scopus 로고
    • Pharyngeal mucosal pressures, airway sealing pressures, and fiberoptic position with the intubating versus the standard laryngeal mask airway
    • DOI 10.1097/00000542-199904000-00012
    • Keller C, Brimacombe J. Pharyngeal mucosal pressures, airway sealing pressures, and fibreoptic position with the intubating versus the standard laryngeal mask airway. Anesthesiology 1999 90 : 1001 1006. (Pubitemid 29159756)
    • (1999) Anesthesiology , vol.90 , Issue.4 , pp. 1001-1006
    • Keller, C.1    Brimacombe, J.2
  • 17
    • 0036174227 scopus 로고    scopus 로고
    • Comparison of times to achieve tracheal intubation with three techniques using the laryngeal or intubating laryngeal mask airway
    • Pandit JJ, Maclachlan K, Dravid RM, Popat MT. Comparison of times to achieve tracheal intubation with three techniques using the laryngeal or intubating laryngeal mask airway. Anaesthesia 2002 57 : 128 132.
    • (2002) Anaesthesia , vol.57 , pp. 128-132
    • Pandit, J.J.1    MacLachlan, K.2    Dravid, R.M.3    Popat, M.T.4
  • 18
    • 0036172383 scopus 로고    scopus 로고
    • Positive pressure ventilation during fibreoptic intubation: Comparison of the laryngeal mask airway, intubating laryngeal mask and endoscopy mask techniques
    • Aoyama K, Yasunaga E, Takenaga I, Kadoya T, Sata T, Shigematsu A. Positive pressure ventilation during fibreoptic intubation: comparison of the laryngeal mask airway, intubating laryngeal mask and endoscopy mask techniques. British Journal of Anaesthesia 2002 88 : 246 254.
    • (2002) British Journal of Anaesthesia , vol.88 , pp. 246-254
    • Aoyama, K.1    Yasunaga, E.2    Takenaga, I.3    Kadoya, T.4    Sata, T.5    Shigematsu, A.6
  • 19
    • 0033017079 scopus 로고    scopus 로고
    • The intubating laryngeal mask airway with and without fiberoptic guidance
    • Joo HS, Rose KD. The intubating laryngeal mask airway with and without fiberoptic guidance. Anesthesia and Analgesia 1999 88 : 662 666.
    • (1999) Anesthesia and Analgesia , vol.88 , pp. 662-666
    • Joo, H.S.1    Rose, K.D.2
  • 21
  • 22
    • 11444261960 scopus 로고    scopus 로고
    • Is ethical approval necessary for manikin studies?
    • Cann C, Hall JE, Sudheer PS, Turley A. Is ethical approval necessary for manikin studies? Anaesthesia 2005 60 : 94 5.
    • (2005) Anaesthesia , vol.60 , pp. 94-5
    • Cann, C.1    Hall, J.E.2    Sudheer, P.S.3    Turley, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.