메뉴 건너뛰기




Volumn 24, Issue 1, 2008, Pages 45-50

Radiofrequency Catheter Ablation with the Use of a Noncontact Mapping System for Ventricular Tachycardia Originating from the Aortic Sinus Cusp-A Case Report-

Author keywords

Aortic sinus cusp; Noncontact mapping; Ventricular tachycardia

Indexed keywords


EID: 77954500000     PISSN: 18804276     EISSN: 18832148     Source Type: Journal    
DOI: 10.4020/jhrs.24.45     Document Type: Article
Times cited : (2)

References (11)
  • 1
    • 0033580599 scopus 로고    scopus 로고
    • Feasibility of a noncontact catheter for endocardial mapping of human ventricular tachycardia
    • Schilling RJ, Peters NS, Davies DW: Feasibility of a noncontact catheter for endocardial mapping of human ventricular tachycardia. Circulation 1999; 99: 2543-2552
    • (1999) Circulation , vol.99 , pp. 2543-2552
    • Schilling, R.J.1    Peters, N.S.2    Davies, D.W.3
  • 2
    • 34249727201 scopus 로고    scopus 로고
    • Catheter ablation of multiple ventricular tachycardias after myocardial infarction guided by combined contact and noncontact mapping
    • Klemm HU, Ventura R, Steven D, et al: Catheter ablation of multiple ventricular tachycardias after myocardial infarction guided by combined contact and noncontact mapping. Circulation 2007; 115: 2697-2704
    • (2007) Circulation , vol.115 , pp. 2697-2704
    • Klemm, H.U.1    Ventura, R.2    Steven, D.3
  • 3
    • 33845520460 scopus 로고    scopus 로고
    • Feasibility of the transseptal approach for fast and unstable left ventricular tachycardia mapping and ablation with a non-contact mapping system
    • Pratola C, Baldo E, Notarstefano P: Feasibility of the transseptal approach for fast and unstable left ventricular tachycardia mapping and ablation with a non-contact mapping system. J Interv Card Electrophysiol 2006; 16: 111-116
    • (2006) J Interv Card Electrophysiol , vol.16 , pp. 111-116
    • Pratola, C.1    Baldo, E.2    Notarstefano, P.3
  • 4
    • 25444471791 scopus 로고    scopus 로고
    • Electrophysiological characteristics and catheter ablation in patients with paroxysmal atrial fibrillation
    • Lin YJ, Tai CT, Tso HW, et al: Electrophysiological characteristics and catheter ablation in patients with paroxysmal atrial fibrillation. Circulation 2005; 112: 1692-1700
    • (2005) Circulation , vol.112 , pp. 1692-1700
    • Lin, Y.J.1    Tai, C.T.2    Tso, H.W.3
  • 5
    • 4444253643 scopus 로고    scopus 로고
    • Non-contact mapping to guide radiofrequency ablation of atypical right atrial flutter
    • Tai CT, Liu TY, Lee PC, et al: Non-contact mapping to guide radiofrequency ablation of atypical right atrial flutter. J Am Coll Cardiol 2004; 44: 1080-1086
    • (2004) J Am Coll Cardiol , vol.44 , pp. 1080-1086
    • Tai, C.T.1    Liu, T.Y.2    Lee, P.C.3
  • 6
    • 2942519750 scopus 로고    scopus 로고
    • Characteristics of virtual unipolar electrograms for detecting isthmus block during radiofrequency catheter ablation of typical atrial flutter
    • Lin YJ, Tai CT, Huang JL, et al: Characteristics of virtual unipolar electrograms for detecting isthmus block during radiofrequency catheter ablation of typical atrial flutter. J Am Coll Cardiol 2004; 43: 2300-2304
    • (2004) J Am Coll Cardiol , vol.43 , pp. 2300-2304
    • Lin, Y.J.1    Tai, C.T.2    Huang, J.L.3
  • 8
    • 1642438915 scopus 로고    scopus 로고
    • Influence of high-pass filtering on noncontact mapping and ablation of atrial tachycardias
    • Schnieder M, Ndrepepa G, Weber S, et al: Influence of high-pass filtering on noncontact mapping and ablation of atrial tachycardias. PACE 204; 27: 38-46
    • PACE , vol.204 , pp. 38-46
    • Schnieder, M.1    Ndrepepa, G.2    Weber, S.3
  • 9
    • 7044269271 scopus 로고    scopus 로고
    • Reentrant ventricular tachycardia originating from the aortic sinus cusp: a case report
    • Tsuchiya T, Yamamoto K, Tanaka E, et al: Reentrant ventricular tachycardia originating from the aortic sinus cusp: a case report. J Cardiovasc Electrophysiol 2004; 15: 1216-1219
    • (2004) J Cardiovasc Electrophysiol , vol.15 , pp. 1216-1219
    • Tsuchiya, T.1    Yamamoto, K.2    Tanaka, E.3
  • 10
    • 0033551153 scopus 로고    scopus 로고
    • Mapping of atrial activation with a noncontact multielectrode catheter in dogs
    • Kadish A, Hauck J, Pederson B, et al: Mapping of atrial activation with a noncontact multielectrode catheter in dogs. Circulation 1999; 99: 1906-1913
    • (1999) Circulation , vol.99 , pp. 1906-1913
    • Kadish, A.1    Hauck, J.2    Pederson, B.3
  • 11
    • 33746192658 scopus 로고    scopus 로고
    • Validation of the noncontact mapping system in the left atrium during permanent atrial fibrillation and sinus rhythm
    • Earley MJ, Abrams DJR, Sporton SC, et al: Validation of the noncontact mapping system in the left atrium during permanent atrial fibrillation and sinus rhythm. J Am Coll Cardiol 2006; 48: 485-491
    • (2006) J Am Coll Cardiol , vol.48 , pp. 485-491
    • Earley, M.J.1    Abrams, D.J.R.2    Sporton, S.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.