메뉴 건너뛰기




Volumn 48, Issue 7, 2010, Pages 731-734

An electrooptical muscle contraction sensor

Author keywords

Infrared; Isometric; Isotonic; Muscle contraction; Optical device

Indexed keywords

ELECTROMAGNETIC NOISE; ELECTROOPTICAL SENSORS; INFRARED; INFRARED LIGHT; INVASIVENESS; ISOTONIC CONTRACTION; MOVEMENT ARTIFACTS; MUSCLE CELL; MUSCLE CONTRACTIONS; OPTICAL ABSORPTION;

EID: 77954426859     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/s11517-010-0626-x     Document Type: Article
Times cited : (18)

References (11)
  • 1
    • 0141509902 scopus 로고    scopus 로고
    • Artefact reduction with alternative cuff configurations
    • DOI 10.1109/TBME.2003.817633
    • LNS Andreasen UJJ Struijk 2003 Artefact reduction with alternative cuff configurations IEEE Trans Biomed Eng 50 1160 1166 10.1109/TBME.2003.817633 14560769 (Pubitemid 37187168)
    • (2003) IEEE Transactions on Biomedical Engineering , vol.50 , Issue.10 , pp. 1160-1166
    • Andreasen, L.N.S.1    Struijk, J.J.2
  • 2
    • 0032679527 scopus 로고    scopus 로고
    • NIRS monitoring of muscle contraction to control a prosthetic device
    • 10.1117/12.336926
    • T Bianchi D Zambarbieri G Beltrami G Verni 1999 NIRS monitoring of muscle contraction to control a prosthetic device SPIE Proc 3570 157 163 10.1117/12.336926
    • (1999) SPIE Proc , vol.3570 , pp. 157-163
    • Bianchi, T.1    Zambarbieri, D.2    Beltrami, G.3    Verni, G.4
  • 3
    • 0032673099 scopus 로고    scopus 로고
    • Exact description of the photon migration in anisotropically scattering media
    • 10.1117/12.334377
    • VN Fomenko FM Shwarts MA Shwarts 1998 Exact description of the photon migration in anisotropically scattering media SPIE Proc 3566 47 56 10.1117/12.334377
    • (1998) SPIE Proc , vol.3566 , pp. 47-56
    • Fomenko, V.N.1    Shwarts, F.M.2    Shwarts, M.A.3
  • 8
    • 33750515036 scopus 로고    scopus 로고
    • Myoelectric signal processing for control of powered limb prostheses
    • DOI 10.1016/j.jelekin.2006.08.006, PII S1050641106001027
    • P Parker K Englehart B Hudgins 2006 Myoelectric signal processing for control of powered limb prostheses J Electromyogr Kinesiol 16 541 548 10.1016/j.jelekin.2006.08.006 1:STN:280:DC%2BD28nltFantQ%3D%3D 17045489 (Pubitemid 44666457)
    • (2006) Journal of Electromyography and Kinesiology , vol.16 , Issue.6 , pp. 541-548
    • Parker, P.1    Englehart, K.2    Hudgins, B.3
  • 9
    • 33645224070 scopus 로고    scopus 로고
    • Techniques of EMG signal analysis: Detection, processing, classification and applications
    • 10.1251/bpo115
    • MBI Reaz MS Hussain F Mohd-Yasin 2006 Techniques of EMG signal analysis: detection, processing, classification and applications Biol Proced Online 8 11 35 10.1251/bpo115
    • (2006) Biol Proced Online , vol.8 , pp. 11-35
    • Reaz, M.B.I.1    Hussain, M.S.2    Mohd-Yasin, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.