메뉴 건너뛰기




Volumn 113, Issue 1, 2010, Pages 74-78

Adjustable shunt valve-induced magnetic resonance imaging artifact: A comparative study

Author keywords

Adjustable valve; Artifact; Cerebrospinal fluid shunt; Hydrocephalus; Magnetic resonance imaging; Programmable valve

Indexed keywords

ARTICLE; ARTIFACT; CLINICAL ARTICLE; COMPARATIVE STUDY; DEVICE; DIFFUSION WEIGHTED IMAGING; HUMAN; IN VIVO STUDY; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 77954413872     PISSN: 00223085     EISSN: 19330693     Source Type: Journal    
DOI: 10.3171/2009.9.JNS09171     Document Type: Article
Times cited : (15)

References (21)
  • 1
    • 34247503858 scopus 로고    scopus 로고
    • Advanced MR imaging techniques in the diagnosis of intraaxial brain tumors in adults
    • Al-Okaili RN, Krejza J, Wang S, Woo JH, Melhem ER: Advanced MR imaging techniques in the diagnosis of intraaxial brain tumors in adults. Radiographics 26 (1 Suppl):S173-S189, 2006
    • (2006) Radiographics , vol.26 , Issue.1 SUPPL.
    • Al-Okaili, R.N.1    Krejza, J.2    Wang, S.3    Woo, J.H.4    Melhem, E.R.5
  • 2
    • 34447571941 scopus 로고    scopus 로고
    • Diffusion and perfusion-weighted magnetic resonance imaging techniques in stroke recovery
    • Aronen HJ, Laakso MP, Moser M, Perkiö J: Diffusion and perfusion-weighted magnetic resonance imaging techniques in stroke recovery. Eura Medicophys 43:271-284, 2007
    • (2007) Eura Medicophys , vol.43 , pp. 271-284
    • Aronen, H.J.1    Laakso, M.P.2    Moser, M.3    Perkiö, J.4
  • 4
    • 0034808837 scopus 로고    scopus 로고
    • Diagnostic tools in hydrocephalus
    • Bradley WG: Diagnostic tools in hydrocephalus. Neurosurg Clin N Am 12:661-684, 2001
    • (2001) Neurosurg Clin N Am , vol.12 , pp. 661-684
    • Bradley, W.G.1
  • 5
    • 34147145066 scopus 로고    scopus 로고
    • Magnetic resonance imaging of iron deposition in neurological disorders
    • Brass SD, Chen NK, Mulkern RV, Bakshi R: Magnetic resonance imaging of iron deposition in neurological disorders. Top Magn Reson Imaging 17:31-40, 2006
    • (2006) Top Magn Reson Imaging , vol.17 , pp. 31-40
    • Brass, S.D.1    Chen, N.K.2    Mulkern, R.V.3    Bakshi, R.4
  • 6
    • 0033764068 scopus 로고    scopus 로고
    • A randomized, controlled study of a programmable shunt valve versus a conventional valve for patients with hydrocephalus
    • Czosnyka Z, Czosnyka M, Copeman J, Pickard JD: A randomized, controlled study of a programmable shunt valve versus a conventional valve for patients with hydrocephalus. Neurosurgery 47:1250-1251, 2000
    • (2000) Neurosurgery , vol.47 , pp. 1250-1251
    • Czosnyka, Z.1    Czosnyka, M.2    Copeman, J.3    Pickard, J.D.4
  • 7
    • 0026761085 scopus 로고
    • Safety of the adjustable pressure ventricular valve in magnetic resonance imaging: Problems and solutions
    • Fransen P, Dooms G, Thauvoy C: Safety of the adjustable pressure ventricular valve in magnetic resonance imaging: problems and solutions. Neuroradiology 34:508-509, 1992
    • (1992) Neuroradiology , vol.34 , pp. 508-509
    • Fransen, P.1    Dooms, G.2    Thauvoy, C.3
  • 8
    • 32044439594 scopus 로고    scopus 로고
    • Effect of 3-tesla magnetic resonance imaging on various pressure programmable shunt valves
    • Inoue T, Kuzu Y, Ogasawara K, Ogawa A: Effect of 3-tesla magnetic resonance imaging on various pressure programmable shunt valves. J Neurosurg 103 (2 Suppl):163-165, 2005
    • (2005) J Neurosurg , vol.103 , Issue.2 SUPPL. , pp. 163-165
    • Inoue, T.1    Kuzu, Y.2    Ogasawara, K.3    Ogawa, A.4
  • 9
    • 24944466493 scopus 로고    scopus 로고
    • Effect of 3 T MRI on the function of shunt valves - Evaluation of Paedi GAV, Dual Switch and proGAV
    • Lindner D, Preul C, Trantakis C, Moeller H, Meixensberger J: Effect of 3 T MRI on the function of shunt valves - evaluation of Paedi GAV, Dual Switch and proGAV. Eur J Radiol 56: 56-59, 2005
    • (2005) Eur J Radiol , vol.56 , pp. 56-59
    • Lindner, D.1    Preul, C.2    Trantakis, C.3    Moeller, H.4    Meixensberger, J.5
  • 10
    • 14944359223 scopus 로고    scopus 로고
    • Reliability of a new adjustable shunt device without the need for readjustment following 3-Tesla MRI
    • Lüdemann W, Rosahl SK, Kaminsky J, Samii M: Reliability of a new adjustable shunt device without the need for readjustment following 3-Tesla MRI. Childs Nerv Syst 21:227-229, 2005
    • (2005) Childs Nerv Syst , vol.21 , pp. 227-229
    • Lüdemann, W.1    Rosahl, S.K.2    Kaminsky, J.3    Samii, M.4
  • 11
    • 33846670577 scopus 로고    scopus 로고
    • Adjustable vs. set-pressure valves decrease the risk of proximal shunt obstruction in the treatment of pediatric hydrocephalus
    • McGirt MJ, Buck DW II, Sciubba D, Woodworth GF, Carson B, Weingart J, et al: Adjustable vs. set-pressure valves decrease the risk of proximal shunt obstruction in the treatment of pediatric hydrocephalus. Childs Nerv Syst 23:289-295, 2007
    • (2007) Childs Nerv Syst , vol.23 , pp. 289-295
    • McGirt, M.J.1    Buck II, D.W.2    Sciubba, D.3    Woodworth, G.F.4    Carson, B.5    Weingart, J.6
  • 12
    • 85052609634 scopus 로고    scopus 로고
    • Is it possible to optimize treatment of patients with idiopathic normal pressure hydrocephalus by im planting an adjustable Medos Hakim valve in combination with a Miethke shunt assistant?
    • Meier U, Lemcke J: Is it possible to optimize treatment of patients with idiopathic normal pressure hydrocephalus by im planting an adjustable Medos Hakim valve in combination with a Miethke shunt assistant? Acta Neurochir Suppl 96: 381-385, 2006
    • (2006) Acta Neurochir Suppl , vol.96 , pp. 381-385
    • Meier, U.1    Lemcke, J.2
  • 13
    • 24744444958 scopus 로고    scopus 로고
    • Magnetic resonance imaging artifacts caused by aneurysm clips and shunt valves: Dependence on field strength (1.5 and 3 T) and imaging parameters
    • Olsrud J, Lätt J, Brockstedt S, Romner B, Björkman-Burtscher IM: Magnetic resonance imaging artifacts caused by aneurysm clips and shunt valves: dependence on field strength (1.5 and 3 T) and imaging parameters. J Magn Reson Imaging 22:433-437, 2005
    • (2005) J Magn Reson Imaging , vol.22 , pp. 433-437
    • Olsrud, J.1    Lätt, J.2    Brockstedt, S.3    Romner, B.4    Björkman-Burtscher, I.M.5
  • 14
    • 0030946803 scopus 로고    scopus 로고
    • Transcutaneous pressure-adjust able valves and magnetic resonance imaging: An ex vivo examination of the Codman-Medos programmable valve and the Sophy adjustable pressure valve
    • Ortler M, Kostron H, Felber S: Transcutaneous pressure-adjust able valves and magnetic resonance imaging: an ex vivo examination of the Codman-Medos programmable valve and the Sophy adjustable pressure valve. Neurosurgery 40: 1050-1058, 1997
    • (1997) Neurosurgery , vol.40 , pp. 1050-1058
    • Ortler, M.1    Kostron, H.2    Felber, S.3
  • 16
    • 34547107299 scopus 로고    scopus 로고
    • Principles and implementation of diffusion-weighted and diffusion tensor imaging
    • Roberts TP, Schwartz ES: Principles and implementation of diffusion-weighted and diffusion tensor imaging. Pediatr Radiol 37:739-748, 2007
    • (2007) Pediatr Radiol , vol.37 , pp. 739-748
    • Roberts, T.P.1    Schwartz, E.S.2
  • 17
    • 33745909421 scopus 로고    scopus 로고
    • Programmable CSF shunt valve: In vitro assessment of MR imaging safety at 3T
    • Shellock FG, Habibi R, Knebel J: Programmable CSF shunt valve: in vitro assessment of MR imaging safety at 3T. AJNR Am J Neuroradiol 27:661-665, 2006
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 661-665
    • Shellock, F.G.1    Habibi, R.2    Knebel, J.3
  • 18
    • 34547734900 scopus 로고    scopus 로고
    • Magnetically programmable shunt valve: MRI at 3-Tesla
    • Shellock FG, Wilson SF, Mauge CP: Magnetically programmable shunt valve: MRI at 3-Tesla. Magn Reson Imaging 25: 1116-1121, 2007
    • (2007) Magn Reson Imaging , vol.25 , pp. 1116-1121
    • Shellock, F.G.1    Wilson, S.F.2    Mauge, C.P.3
  • 19
    • 42449094664 scopus 로고    scopus 로고
    • Radiation-induced meningioma concealed by shunt valve artifact: Case report
    • Singleton RH, Kellermier H, Lunsford D: Radiation-induced meningioma concealed by shunt valve artifact: case report. Neurosurgery 62:E743-E744, 2008
    • (2008) Neurosurgery , vol.62
    • Singleton, R.H.1    Kellermier, H.2    Lunsford, D.3
  • 20
    • 34250723800 scopus 로고    scopus 로고
    • Changing concepts of cerebrospinal fluid hydrodynamics: Role of phase-contrast magnetic resonance imaging and implications for cerebral microvascular disease
    • Stivaros SM, Jackson A: Changing concepts of cerebrospinal fluid hydrodynamics: role of phase-contrast magnetic resonance imaging and implications for cerebral microvascular disease. Neurotherapeutics 4:511-522, 2007
    • (2007) Neurotherapeutics , vol.4 , pp. 511-522
    • Stivaros, S.M.1    Jackson, A.2
  • 21
    • 33845694741 scopus 로고    scopus 로고
    • The role of different imaging modalities: Is MRI a conditio sine qua non for ETV?
    • Van Lindert EJ, Beems T, Grotenhuis JA: The role of different imaging modalities: is MRI a conditio sine qua non for ETV? Childs Nerv Syst 22:1529-1536, 2006
    • (2006) Childs Nerv Syst , vol.22 , pp. 1529-1536
    • Van Lindert, E.J.1    Beems, T.2    Grotenhuis, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.