메뉴 건너뛰기




Volumn 135, Issue 28-29, 2010, Pages 1418-1422

Contact allergy to metals and bone cement components in patients with intolerance of arthroplasty;Kontaktallergieraten gegen Metalle und Knochenzementbestandteile bei Patienten mit Endoprothesenunverträglichkeit

Author keywords

allergy; arthroplasty; bone cement; implant; metal; patch test

Indexed keywords

BENZOYL PEROXIDE; BONE CEMENT; CHROMIUM; COBALT; GENTAMICIN; HYDROQUINONE; METAL;

EID: 77954406273     PISSN: 00120472     EISSN: 14394413     Source Type: Journal    
DOI: 10.1055/s-0030-1262426     Document Type: Article
Times cited : (20)

References (40)
  • 2
    • 1242352620 scopus 로고    scopus 로고
    • Release of gentamicin and vancomycin from temporary human hip spacers in two-stage revision of infected arthroplasty
    • DOI 10.1093/jac/dkh032
    • Bertazzoni Minelli E, Benini A, Magnan B, Bartolozzi P. Release of gentamicin and vancomycin from temporary human hip spacers in two-stage revision of infected arthroplasty. J Antimicrob Chemother 2004 53 329-334 (Pubitemid 38239970)
    • (2004) Journal of Antimicrobial Chemotherapy , vol.53 , Issue.2 , pp. 329-334
    • Bertazzoni Minelli, E.1    Benini, A.2    Magnan, B.3    Bartolozzi, P.4
  • 3
    • 0038583786 scopus 로고    scopus 로고
    • Knochenzemente auf basis von polymethylmethacrylat
    • DOI 10.1007/s00132-002-0411-0
    • Breusch S J., Kuhn K D. Knochenzement auf Basis von Polymethylmethacrylat. Orthopäde 2003 32 41-50 (Pubitemid 36596591)
    • (2003) Orthopade , vol.32 , Issue.1 , pp. 41-50
    • Breusch, S.J.1    Kuhn, K.-D.2
  • 4
    • 0023949961 scopus 로고
    • Allergy and occupational exposure to hydroquinone and to methionine
    • Choudat D, Neukirch F, Brochard P et al. Allergy and occupational exposure to hydroquinone and to methionine. Br J Ind Med 1988 45 376-380
    • (1988) Br J Ind Med , vol.45 , pp. 376-380
    • Choudat, D.1    Neukirch, F.2    Brochard, P.3
  • 5
    • 64949156980 scopus 로고    scopus 로고
    • Hypersensitivity to polmethylmethacrylate following shoulder hemiarthroplasty
    • Erpenbach J, Hofmeister E. Hypersensitivity to polmethylmethacrylate following shoulder hemiarthroplasty. Orthopedics 2008 31 708
    • (2008) Orthopedics , vol.31 , pp. 708
    • Erpenbach, J.1    Hofmeister, E.2
  • 6
    • 2342595790 scopus 로고    scopus 로고
    • Gentamicin concentrations in diagnostic aspirates from 25 patients with hip and knee arthroplasties
    • Fletcher M D., Spencer R F., Langkamer V G., Lovering A M. Gentamicin concentrations in diagnostic aspirates from 25 patients with hip and knee arthroplasties. Acta Orthop Scand 2004 75 173-176
    • (2004) Acta Orthop Scand , vol.75 , pp. 173-176
    • Fletcher, M.D.1    Spencer, R.F.2    Langkamer, V.G.3    Lovering, A.M.4
  • 7
    • 0036822977 scopus 로고    scopus 로고
    • Benzoyl peroxide as a cause of airborne contact dermatitis in an orthopaedic technician
    • DOI 10.1034/j.1600-0536.2002.470415.x
    • Forschner K, Zuberbier T, Worm M. Benzoyl peroxide as a cause of airborne contact dermatitis in an orthopaedic technician. Contact Dermatitis 2002 47 241 (Pubitemid 36132498)
    • (2002) Contact Dermatitis , vol.47 , Issue.4 , pp. 241
    • Forschner, K.1    Zuberbier, T.2    Worm, M.3
  • 8
    • 0029864111 scopus 로고    scopus 로고
    • Evaluation of patch test results with denture material series
    • DOI 10.1111/j.1600-0536.1996.tb02172.x
    • Gebhart M, Geier J. Evaluation of patch test results with denture material series. Contact Dermatitis 1996 34 191-195 (Pubitemid 26083671)
    • (1996) Contact Dermatitis , vol.34 , Issue.3 , pp. 191-195
    • Gebhardt, M.1    Geier, J.2
  • 9
    • 46649108712 scopus 로고    scopus 로고
    • Allergologische Diagnostik bei Verdacht auf Implantatunverträ glichkeit: Hinweise für die Praxis. Eine Stellungnahme der Deutschen Kontaktallergie-Gruppe (DKG)
    • Geier J, Lessmann H, Becker D, Thomas P. Allergologische Diagnostik bei Verdacht auf Implantatunverträglichkeit: Hinweise für die Praxis. Eine Stellungnahme der Deutschen Kontaktallergie-Gruppe (DKG). Hautarzt 2008 59 594-597
    • (2008) Hautarzt , vol.59 , pp. 594-597
    • Geier, J.1    Lessmann, H.2    Becker, D.3    Thomas, P.4
  • 10
    • 0028473306 scopus 로고
    • Effect of dentine on release of TEGDMA from resin composite in vitro
    • Gerzina T M., Hume W R. Effect of dentine on release of TEGDMA from resin composite in vitro. J Oral Rehabil 1994 21 463-468
    • (1994) J Oral Rehabil , vol.21 , pp. 463-468
    • Gerzina, T.M.1    Hume, W.R.2
  • 11
    • 0029688759 scopus 로고    scopus 로고
    • Diffusion of monomers from bonding resin-resin composite combinations through dentine in vitro
    • Gerzina T M., Hume W R. Diffusion of monomers from bonding resin-resin composite combinations through dentine in vitro. J Dent 1996 24 125-128
    • (1996) J Dent , vol.24 , pp. 125-128
    • Gerzina, T.M.1    Hume, W.R.2
  • 12
    • 77954397379 scopus 로고    scopus 로고
    • Wintermantel E, Ha S-W Medizintechnik mit biokompatiblen Werkstoffen und Verfahren. Berlin Springer
    • Ha S-W, Wintermantel E, Maier G. Werkstoffe in der Medizintechnik: Polymere. In: Wintermantel E, Ha S-W Medizintechnik mit biokompatiblen Werkstoffen und Verfahren. Berlin Springer 2002 161-192
    • (2002) Werkstoffe in der Medizintechnik: Polymere , pp. 161-192
    • Ha, S.-W.1    Wintermantel, E.2    Maier, G.3
  • 15
    • 61349131924 scopus 로고    scopus 로고
    • Is gentamicin-loaded bone cement a risk for developing allergic dermatitis?
    • Haeberle M, Wittner B. Is gentamicin-loaded bone cement a risk for developing allergic dermatitis? Contact Dermatitis 2009 60 176-177
    • (2009) Contact Dermatitis , vol.60 , pp. 176-177
    • Haeberle, M.1    Wittner, B.2
  • 16
    • 0034887654 scopus 로고    scopus 로고
    • Metal sensitivity in patients with orthopedic implants
    • Hallab N. Metal sensitivity in patients with orthopedic implants. J Clin Rheumatol 2001 7 215-218 (Pubitemid 32776270)
    • (2001) Journal of Clinical Rheumatology , vol.7 , Issue.4 , pp. 215-218
    • Hallab, N.1
  • 17
    • 0033042675 scopus 로고    scopus 로고
    • Patch-test reactions to plastic and glue allergens
    • DOI 10.1080/000155599750010706
    • Kanerva L, Jolanki R, Alanko K, Estlander T. Patch-test reactions to plastic and glue allergens. Acta Derm Venereol 1999 79 296-300 (Pubitemid 29302059)
    • (1999) Acta Dermato-Venereologica , vol.79 , Issue.4 , pp. 296-300
    • Kanerva, L.1    Jolanki, R.2    Alanko, K.3    Estlander, T.4
  • 18
    • 0021206738 scopus 로고
    • Contact dermatitis to methyl methacrylate
    • Kassis V, Vedel P, Darre E. Contact dermatitis to methyl methacrylate. Contact Dermatitis 1984 11 26-28 (Pubitemid 14077528)
    • (1984) Contact Dermatitis , vol.11 , Issue.1 , pp. 26-28
    • Kassis, V.1    Vedel, P.2    Darre, E.3
  • 19
    • 0034909392 scopus 로고    scopus 로고
    • Allergic contact stomatitis caused by acrylic monomer in a denture
    • DOI 10.1046/j.1440-0960.2001.00517.x
    • Koutis D, Freeman S. Allergic contact stomatitis caused by acrylic monomer in a denture. Australas J Dermatol 2001 42 203-206 (Pubitemid 32721564)
    • (2001) Australasian Journal of Dermatology , vol.42 , Issue.3 , pp. 203-206
    • Koutis, D.1    Freeman, S.2
  • 21
    • 1242269405 scopus 로고    scopus 로고
    • The Development of Theoretical Relationships between Some Handling Parameters (Setting Time and Setting Temperature), Composition (Relative Amounts of Initiator and Activator) and Ambient Temperature for Acrylic Bone Cement
    • Milner R. The development of theoretical relationships between some handling parameters (setting time and setting temperature), composition (relative amounts of initiator and activator) and ambient temperature for acrylic bone cement. J Biomed Mater Res B Appl Biomater 2004 68 180-185 (Pubitemid 38222237)
    • (2004) Journal of Biomedical Materials Research - Part B Applied Biomaterials , vol.68 , Issue.2 , pp. 180-185
    • Milner, R.1
  • 24
    • 0031855624 scopus 로고    scopus 로고
    • Gentamicin release from old cement during revision hip arthroplasty
    • Powles J W., Spencer R F., Lovering A M. Gentamicin release from old cement during revision hip arthroplasty. J Bone Joint Surg Br 1998 80 607-610
    • (1998) J Bone Joint Surg Br , vol.80 , pp. 607-610
    • Powles, J.W.1    Spencer, R.F.2    Lovering, A.M.3
  • 25
    • 6344261459 scopus 로고    scopus 로고
    • Prothesenunverträglichkeit bei Typ-IV-sensibilisierung gegen knochenzement
    • DOI 10.1007/s00105-004-0814-4
    • Richter-Hintz D, Rieker J, Rauch L, Homey B. Prothesenunverträ glichkeit bei Typ-IV-Sensibilisierung gegen Knochenzement. Hautarzt 2004 55 1432-1173 (Pubitemid 39387954)
    • (2004) Hautarzt , vol.55 , Issue.10 , pp. 987-989
    • Richter-Hintz, D.1    Rieker, J.2    Rauch, L.3    Homey, B.4
  • 26
    • 84984372140 scopus 로고
    • Methyl methacrylate prosthesis dermatitis
    • DOI 10.1111/j.1600-0536.1985.tb01088.x
    • Romaguera C, Grimalt F, Vilaplana J. Methyl methacrylate prosthesis dermatitis. Contact Dermatitis 1985 12 172 (Pubitemid 15133939)
    • (1985) Contact Dermatitis , vol.12 , Issue.3 , pp. 172
    • Romaguera, C.1    Grimalt, F.2    Vilaplana, J.3
  • 27
    • 0028578778 scopus 로고
    • Kontaktallergien in medizinischen Berufen
    • Rustemeyer T, Pilz B, Frosch P J. Kontaktallergien in medizinischen Berufen. Hautarzt 1994 45 834-844
    • (1994) Hautarzt , vol.45 , pp. 834-844
    • Rustemeyer, T.1    Pilz, B.2    Frosch, P.J.3
  • 29
    • 47249151917 scopus 로고    scopus 로고
    • Häufigkeit von Allergien gegen Implantatwerkstoffe in der Hüft- und Knieendoprothetik
    • Schuh A, Lill C, Hnle W, Effenberger H. Häufigkeit von Allergien gegen Implantatwerkstoffe in der Hüft- und Knieendoprothetik. Zentralbl Chir 2008 133 292-296
    • (2008) Zentralbl Chir , vol.133 , pp. 292-296
    • Schuh, A.1    Lill, C.2    Hnle, W.3    Effenberger, H.4
  • 31
    • 34250654178 scopus 로고    scopus 로고
    • Patch test reactivity to a cobalt-chromium-molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release
    • DOI 10.1111/j.1600-0536.2007.01139.x
    • Summer B, Fink U, Zeller R et al. Patch test reactivity to a cobalt-chromium-molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release. Contact Dermatitis 2007 57 35-39 (Pubitemid 46944438)
    • (2007) Contact Dermatitis , vol.57 , Issue.1 , pp. 35-39
    • Summer, B.1    Fink, U.2    Zeller, R.3    Rueff, F.4    Maier, S.5    Roider, G.6    Thomas, P.7
  • 33
    • 0037907585 scopus 로고    scopus 로고
    • Allergien durch implantatwerkstoffe
    • DOI 10.1007/s00132-002-0413-y
    • Thomas P. Allergien durch Implantatwerkstoffe. Orthopäde 2003 32 60-64 (Pubitemid 36596593)
    • (2003) Orthopade , vol.32 , Issue.1 , pp. 60-64
    • Thomas, P.1
  • 35
    • 38649085629 scopus 로고    scopus 로고
    • Orthopädisch-chirurgische Implantate und Allergien. Gemeinsame Stellungnahme des Arbeitskreises Implantatallergie (AK 20) der Deutschen Gesellschaft für Orthopädie und Orthopädische Chirurgie (DGOOC), der Deutschen Kontaktallergie Gruppe (DKG) und der Deutschen Gesellschaft für Allergologie und Klinische Immunologie (DGAKI)
    • Thomas P, Schuh A, Ring J, Thomsen M. Orthopädisch-chirurgische Implantate und Allergien. Gemeinsame Stellungnahme des Arbeitskreises Implantatallergie (AK 20) der Deutschen Gesellschaft für Orthopädie und Orthopädische Chirurgie (DGOOC), der Deutschen Kontaktallergie Gruppe (DKG) und der Deutschen Gesellschaft für Allergologie und Klinische Immunologie (DGAKI). Orthopäde 2008 37 75-88
    • (2008) Orthopäde , vol.37 , pp. 75-88
    • Thomas, P.1    Schuh, A.2    Ring, J.3    Thomsen, M.4
  • 36
    • 0031193673 scopus 로고    scopus 로고
    • Optimization of benzoyl peroxide concentration in an experimental bone cement based on poly(methyl methacrylate)
    • DOI 10.1023/A:1018565807727
    • Valquez B, Deb S, Bonfield W. Optimization of benzoyl peroxide concentration in an experimental bone cement based on poly(methyl methacrylate). J Mater Sci Mater Med 1997 8 455-460 (Pubitemid 27313791)
    • (1997) Journal of Materials Science: Materials in Medicine , vol.8 , Issue.7 , pp. 455-460
    • Vazquez, B.1    Deb, S.2    Bonfield, W.3
  • 37
    • 0015408186 scopus 로고
    • Experimental and clinical studies on the release of gentamicin from bone cement
    • Wahlig H, Buchholz H W. Experimental and clinical studies on the release of gentamicin from bone cement. Chirurg 1972 43 441-445
    • (1972) Chirurg , vol.43 , pp. 441-445
    • Wahlig, H.1    Buchholz, H.W.2
  • 40
    • 0030331916 scopus 로고    scopus 로고
    • Tissue reactions to plastic and metallic wear products of joint endoprostheses
    • Willert H G., Semlitsch M. Tissue reactions to plastic and metallic wear products of joint endoprostheses. Clin Orthop Relat Res 1996 333 4-14
    • (1996) Clin Orthop Relat Res , vol.333 , pp. 4-14
    • Willert, H.G.1    Semlitsch, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.