Volumn , Issue , 2010, Pages 92-96

Design of a gel-less two-electrode ECG monitor

Author keywords

ECG amplifier; Heart rate monitoring; Portable medical device; Two electrode ECG

Indexed keywords

AMPLIFIER DESIGNS; AMPLIFIER SATURATION; BASELINE CORRECTION; COMMON-MODE NOISE; DC VOLTAGE; DIGITAL SIGNALS; ECG MONITOR; HEART RATE MONITORING; HEART RATES; LOW POWER; NO REFERENCES; PHYSICAL ACTIVITY; PORTABLE APPLICATIONS; PORTABLE MEDICAL DEVICE;

EID: 77954402191     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MEMEA.2010.5480198     Document Type: Conference Paper
Times cited : (26)

References (26)
  • 1
    • 0023223146 scopus 로고
    • Heart rate and cardiovascular mortality: The Framingham Study
    • Jun.
    • W. B. Kannel, C. Kannel, R. S. Paffenbarger Jr and L. A. Cupples, "Heart rate and cardiovascular mortality: the Framingham Study," Am. Heart J., vol. 113, pp. 1489-1494, Jun. 1987.
    • (1987) Am. Heart J. , vol.113 , pp. 1489-1494
    • Kannel, W.B.1    Kannel, C.2    Paffenbarger Jr., R.S.3    Cupples, L.A.4
  • 2
    • 0026097807 scopus 로고
    • Pulse rate, coronary heart disease, and death: The NHANES I Epidemiologic Follow-up Study
    • R. F. Gillum, D. M. Makuc and J. J. Feldman, "Pulse rate, coronary heart disease, and death: the NHANES I Epidemiologic Follow-up Study," Am. Heart J., vol. 121, pp. 172-177, 1991.
    • (1991) Am. Heart J. , vol.121 , pp. 172-177
    • Gillum, R.F.1    Makuc, D.M.2    Feldman, J.J.3
  • 3
    • 0031106763 scopus 로고    scopus 로고
    • A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV
    • Ruha, S. Sallinen and S. Nissila, "A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV," IEEE Transactions on Biomedical Engineering, vol. 44, pp. 159-167, 1997.
    • (1997) IEEE Transactions on Biomedical Engineering , vol.44 , pp. 159-167
    • Ruha, S.S.1    Nissila, S.2
  • 6
    • 0034205642 scopus 로고    scopus 로고
    • A comprehensive model for power line interference in biopotential measurements
    • Jun.
    • M. F. Chimeno and R. Pallas-Areny, "A comprehensive model for power line interference in biopotential measurements," IEEE Trans. Instrum. Meas., vol. 49, no. 3, pp. 535-540, Jun. 2000.
    • (2000) IEEE Trans. Instrum. Meas. , vol.49 , Issue.3 , pp. 535-540
    • Chimeno, M.F.1    Pallas-Areny, R.2
  • 11
    • 77954394436 scopus 로고
    • High Q Notch Filter
    • Anonymous, March at
    • Anonymous, "High Q Notch Filter," National Semiconductor Linear Brief 5, March 1969, at http://www.national.com/ms/LB/LB-5.pdf
    • (1969) National Semiconductor Linear Brief 5
  • 13
    • 0026154666 scopus 로고
    • Integer coefficient bandpass filter for the simultaneous removal of baseline wander, 50 and 100 Hz interference from the ECG
    • R. Warlar and C. Eswaran, "Integer coefficient bandpass filter for the simultaneous removal of baseline wander, 50 and 100 Hz interference from the ECG," Medical and Biological Engineering and Computing, vol. 29, pp. 333-336, 1991.
    • (1991) Medical and Biological Engineering and Computing , vol.29 , pp. 333-336
    • Warlar, R.1    Eswaran, C.2
  • 14
    • 0015579764 scopus 로고
    • Phase distortion of biological signals: Extraction of signal from noise without phase error
    • W. W. Dawson and H. W. Doddington, "Phase distortion of biological signals: extraction of signal from noise without phase error," Electroencephalogr. Clin. Neurophysiol., vol. 34, pp. 207-211, 1973.
    • (1973) Electroencephalogr. Clin. Neurophysiol. , vol.34 , pp. 207-211
    • Dawson, W.W.1    Doddington, H.W.2
  • 15
    • 0020767564 scopus 로고
    • Signal distortion in the electrocardiogram due to inadequate phase response
    • D. Tayler and R. Vincent, "Signal distortion in the electrocardiogram due to inadequate phase response," IEEE Transactions on Biomedical Engineering, pp. 352-356, 1983.
    • (1983) IEEE Transactions on Biomedical Engineering , pp. 352-356
    • Tayler, D.1    Vincent, R.2
  • 16
    • 0036119477 scopus 로고    scopus 로고
    • Two-electrode biopotential amplifier with current-driven inputs
    • Dobrev and I. Daskalov, "Two-electrode biopotential amplifier with current-driven inputs," Medical and Biological Engineering and Computing, vol. 40, pp. 122-127, 2002.
    • (2002) Medical and Biological Engineering and Computing , vol.40 , pp. 122-127
    • Dobrev1    Daskalov, I.2
  • 17
    • 2342429744 scopus 로고    scopus 로고
    • Two-electrode low supply voltage electrocardiogram signal amplifier
    • Dobrev, "Two-electrode low supply voltage electrocardiogram signal amplifier," Medical and Biological Engineering and Computing, vol. 42, pp. 272-276, 2004.
    • (2004) Medical and Biological Engineering and Computing , vol.42 , pp. 272-276
    • Dobrev1
  • 18
    • 0034048104 scopus 로고    scopus 로고
    • A direct comparison of wet, dry and insulating bioelectric recording electrodes
    • Searle and L. Kirkup, "A direct comparison of wet, dry and insulating bioelectric recording electrodes," Physiol. Meas., vol. 21, pp. 271-284, 2000.
    • (2000) Physiol. Meas. , vol.21 , pp. 271-284
    • Searle1    Kirkup, L.2
  • 19
    • 35848931902 scopus 로고    scopus 로고
    • Novel dry electrodes for ECG monitoring
    • Gruetzmann, S. Hansen and J. Müller, "Novel dry electrodes for ECG monitoring," Physiol. Meas., vol. 28, pp. 1375-1390, 2007.
    • (2007) Physiol. Meas. , vol.28 , pp. 1375-1390
    • Gruetzmann1    Hansen, S.2    Müller, J.3
  • 20
    • 0025095175 scopus 로고
    • Recommendations for standardization and specifications in automated electrocardiography: Bandwidth and digital signal processing
    • Feb.
    • J. J. Baily, A. S. Berson, A. J. Garson, L. G. Horan, P. W. Macfarlane, D. W. Mortara and C. Zywietz, "Recommendations for standardization and specifications in automated electrocardiography: bandwidth and digital signal processing," Circulation, vol. 81, pp. 730-739, Feb. 1990.
    • (1990) Circulation , vol.81 , pp. 730-739
    • Baily, J.J.1    Berson, A.S.2    Garson, A.J.3    Horan, L.G.4    Macfarlane, P.W.5    Mortara, D.W.6    Zywietz, C.7
  • 21
    • 0028532655 scopus 로고
    • Low-power ECG amplifier/detector for dry-electrode heart rate monitoring
    • M. J. Burke, "Low-power ECG amplifier/detector for dry-electrode heart rate monitoring," Medical and Biological Engineering and Computing, vol. 32, pp. 678-683, 1994.
    • (1994) Medical and Biological Engineering and Computing , vol.32 , pp. 678-683
    • Burke, M.J.1
  • 24
    • 0020641938 scopus 로고
    • Reduction of Interference Due to Common Mode Voltage in Biopotential Amplifiers
    • B. Winter and J. G. Webster, "Reduction of Interference Due to Common Mode Voltage in Biopotential Amplifiers," Biomedical Engineering, IEEE Transactions on, vol. BME-30, pp. 58-62, 1983.
    • (1983) Biomedical Engineering, IEEE Transactions on , vol.BME-30 , pp. 58-62
    • Winter, B.1    Webster, J.G.2
  • 25
    • 0022812782 scopus 로고
    • On the Reduction of Interference Due to Common Mode Voltage in Two-Electrode Biopotential Amplifiers
    • R. Pallas-Areny, "On the Reduction of Interference Due to Common Mode Voltage in Two-Electrode Biopotential Amplifiers," Biomedical Engineering, IEEE Transactions on, vol. BME-33, pp. 1043-1046, 1986.
    • (1986) Biomedical Engineering, IEEE Transactions on , vol.BME-33 , pp. 1043-1046
    • Pallas-Areny, R.1
  • 26
    • 77954391815 scopus 로고    scopus 로고
    • CR2032 3V Lithium Battery Technical Data Sheet
    • Anonymous, Rev. CR2032.06/12.06, at
    • Anonymous, "CR2032 3V Lithium Battery Technical Data Sheet," Renata Batteries, Rev. CR2032.06/12.06, at http://www.renata.com/pdf/3vlithium/ CR2032-v06.pdf
    • Renata Batteries


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.