메뉴 건너뛰기




Volumn , Issue , 2010, Pages 19-22

Optical method for measurement of respiration rate

Author keywords

Laser doppler vibrometry; Non contact; Respiration rate

Indexed keywords

AREA-BASED; CAPACITIVE SENSOR; CARDIAC ACTIVITY; CHEST WALL; CONTACT DEVICE; DIRECT CONTACT; LASER DOPPLER VIBROMETERS; LASER DOPPLER VIBROMETRY; MEASUREMENT PROCEDURES; NO-CONTACT; NON-CONTACT; NONCONTACT METHODS; OPTICAL METHODS; OPTIMAL POSITION; REFERENCE INSTRUMENTS; RELATIVE ERRORS; RESPIRATION RATE; STATISTICAL ANALYSIS;

EID: 77954397915     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MEMEA.2010.5480208     Document Type: Conference Paper
Times cited : (29)

References (15)
  • 2
    • 57849158797 scopus 로고    scopus 로고
    • Textile-Based Capacitive Sensors for respiration Monitoring
    • C. R. Merrit, H. T. Nagle, E. Grant, "Textile-Based Capacitive Sensors For respiration Monitoring", IEEE Sensors , 9, 1, pp. 71-78, (2008).
    • (2008) IEEE Sensors , vol.9 , Issue.1 , pp. 71-78
    • Merrit, C.R.1    Nagle, H.T.2    Grant, E.3
  • 3
    • 0033496737 scopus 로고    scopus 로고
    • Monitoring of heart and respiratory rates in newborn infants using a new photoplethysmographic technique
    • A. Johansson, et al., " Monitoring of heart and respiratory rates in newborn infants using a new photoplethysmographic technique", J Clin Monit Comp, 15, 461-467, 1999.
    • (1999) J Clin Monit Comp , vol.15 , pp. 461-467
    • Johansson, A.1
  • 4
    • 85008010119 scopus 로고    scopus 로고
    • Human Life Signs Detection Using High-Sensitivity Pulsed Laser Vibrometer
    • C.C. Wang et al., "Human Life Signs Detection Using High-Sensitivity Pulsed Laser Vibrometer", IEEE Sensors , 7, 9, pp.1370-1376, 2007
    • (2007) IEEE Sensors , vol.7 , Issue.9 , pp. 1370-1376
    • Wang, C.C.1
  • 5
    • 33947186741 scopus 로고    scopus 로고
    • Method for Continuous Nondisturbing Monitoring of Blood Pressure by Magnetoelastic Skin Curvature Sensor and ECG
    • E. Kaniusas, et al. "Method for Continuous Nondisturbing Monitoring of Blood Pressure by Magnetoelastic Skin Curvature Sensor and ECG", IEEE Sensors, 6, 3, pp.819-828, 2006
    • (2006) IEEE Sensors , vol.6 , Issue.3 , pp. 819-828
    • Kaniusas, E.1
  • 6
    • 42949110253 scopus 로고    scopus 로고
    • Non contact cardiac monitoring from carotid artery using optical vibrocardiography
    • L. Scalise, U. Morbiducci "Non contact cardiac monitoring from carotid artery using optical vibrocardiography", Medical Engineering & Physics, 30, 4, pp. 490-497, 2007.
    • (2007) Medical Engineering & Physics , vol.30 , Issue.4 , pp. 490-497
    • Scalise, L.1    Morbiducci, U.2
  • 10
    • 0000004140 scopus 로고
    • Measurement in Meidicine: The Analysis of Method Comparison Studiest
    • D.G.Altman and J. M.Bland. "Measurement in Meidicine: the Analysis of Method Comparison Studiest", The Statistician 32 , 307-317, 1983.
    • (1983) The Statistician , vol.32 , pp. 307-317
    • Altman, D.G.1    Bland, J.M.2
  • 12
    • 33646103154 scopus 로고    scopus 로고
    • Laser Doppler Vibrometry: Development of advanced solutions answering to technology's needs
    • P Castellini, M Martarelli, and EP Tomasini. Laser Doppler Vibrometry: Development of advanced solutions answering to technology's needs. Mechanical Systems and Signal Processing 20(6), 2006:1265-1285
    • (2006) Mechanical Systems and Signal Processing , vol.20 , Issue.6 , pp. 1265-1285
    • Castellini, P.1    Martarelli, M.2    Tomasini, E.P.3
  • 14
    • 33845489135 scopus 로고    scopus 로고
    • Optical vibrocardiography: A novel tool for optical monitoring of cardiac activity
    • U. Morbiducci, L. Scalise, M. De Melis, M. Grigioni, "Optical vibrocardiography: a novel tool for optical monitoring of cardiac activity." Ann. Biomedical Engineering. 2007;35(1):45-58.
    • (2007) Ann. Biomedical Engineering. , vol.35 , Issue.1 , pp. 45-58
    • Morbiducci, U.1    Scalise, L.2    De Melis, M.3    Grigioni, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.