메뉴 건너뛰기




Volumn 36, Issue 7, 2010, Pages 1256-1260

Effect of the AutoPulse™ automated band chest compression device on hemodynamics in out-of-hospital cardiac arrest resuscitation

Author keywords

Cardiac arrest; Hemodynamics; Out of hospital; Resuscitation

Indexed keywords

ADRENALIN;

EID: 77954382681     PISSN: 03424642     EISSN: 14321238     Source Type: Journal    
DOI: 10.1007/s00134-010-1784-x     Document Type: Article
Times cited : (54)

References (19)
  • 1
    • 28444490018 scopus 로고    scopus 로고
    • European resuscitation council guidelines for resuscitation 2005, Section 4. Adult advanced life support
    • 10.1016/j.resuscitation.2005.10.009 16321716
    • JP Nolan CD Deakin J Soar BW Böttiger G Smith 2005 European resuscitation council guidelines for resuscitation 2005, Section 4. Adult advanced life support Resuscitation 67 Suppl 1 S39 S86 10.1016/j.resuscitation. 2005.10.009 16321716
    • (2005) Resuscitation , vol.67 , Issue.SUPPL. 1
    • Nolan, J.P.1    Deakin, C.D.2    Soar, J.3    Böttiger, B.W.4    Smith, G.5
  • 2
    • 28444447937 scopus 로고    scopus 로고
    • 2005 International guidelines conference on cardiopulmonary resuscitation and emergency care science with treatment recommendations. Part 4: Advanced life support
    • International Liaison Committee on Resuscitation. 10.1016/j. resuscitation.2005.09.018
    • International Liaison Committee on Resuscitation 2005 2005 International guidelines conference on cardiopulmonary resuscitation and emergency care science with treatment recommendations. Part 4: advanced life support Resuscitation 67 213 247 10.1016/j.resuscitation.2005.09.018
    • (2005) Resuscitation , vol.67 , pp. 213-247
  • 4
    • 40749128021 scopus 로고    scopus 로고
    • Improved cardiac arrest outcomes: As time goes by?
    • 10.1186/cc5784 17498319
    • PT Morley 2007 Improved cardiac arrest outcomes: as time goes by? Crit Care 11 130 10.1186/cc5784 17498319
    • (2007) Crit Care , vol.11 , pp. 130
    • Morley, P.T.1
  • 5
    • 12244295495 scopus 로고    scopus 로고
    • Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest
    • 10.1001/jama.293.3.299 1:CAS:528:DC%2BD2MXmslalsg%3D%3D 15657322
    • L Wik J Kramer-Johansen H Myklebust H Sørebø L Svensson B Fellows PA Steen 2005 Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest JAMA 293 299 304 10.1001/jama.293.3.299 1:CAS:528:DC%2BD2MXmslalsg%3D%3D 15657322
    • (2005) JAMA , vol.293 , pp. 299-304
    • Wik, L.1    Kramer-Johansen, J.2    Myklebust, H.3    Sørebø, H.4    Svensson, L.5    Fellows, B.6    Steen, P.A.7
  • 6
    • 0032103734 scopus 로고    scopus 로고
    • The effect of rescuer fatigue on the quality of chest compressions
    • 10.1016/S0300-9572(98)00057-4 1:STN:280:DyaK1cznvFKgsw%3D%3D 9715774
    • FJ Ochoa E Ramalle-Gomara V Lisa I Saralegui 1998 The effect of rescuer fatigue on the quality of chest compressions Resuscitation 37 149 152 10.1016/S0300-9572(98)00057-4 1:STN:280:DyaK1cznvFKgsw%3D%3D 9715774
    • (1998) Resuscitation , vol.37 , pp. 149-152
    • Ochoa, F.J.1    Ramalle-Gomara, E.2    Lisa, V.3    Saralegui, I.4
  • 7
    • 9644264150 scopus 로고    scopus 로고
    • Cardiopulmonary resuscitation with a novel chest compression device in a porcine model of cardiac arrest: Improved hemodynamics and mechanisms
    • 10.1016/j.jacc.2004.08.061
    • HR Halperin N Paradis JP Ornato M Zviman J Lacorte A Lardo KB Kern 2004 Cardiopulmonary resuscitation with a novel chest compression device in a porcine model of cardiac arrest: improved hemodynamics and mechanisms J Am Coll Cardiol 44 2212 2214 10.1016/j.jacc.2004.08.061
    • (2004) J Am Coll Cardiol , vol.44 , pp. 2212-2214
    • Halperin, H.R.1    Paradis, N.2    Ornato, J.P.3    Zviman, M.4    Lacorte, J.5    Lardo, A.6    Kern, K.B.7
  • 8
    • 2542476114 scopus 로고    scopus 로고
    • Improved hemodynamic performance with a novel chest compression device during treatment of in-hospital cardiac arrest
    • 10.1016/j.resuscitation.2004.01.025 15172705
    • S Timerman LF Cardoso JA Ramires H Haleprin 2004 Improved hemodynamic performance with a novel chest compression device during treatment of in-hospital cardiac arrest Resuscitation 61 273 280 10.1016/j.resuscitation. 2004.01.025 15172705
    • (2004) Resuscitation , vol.61 , pp. 273-280
    • Timerman, S.1    Cardoso, L.F.2    Ramires, J.A.3    Haleprin, H.4
  • 12
    • 33847392166 scopus 로고    scopus 로고
    • Out-of-hospital cardiopulmonary resuscitation with Autopulse system: A prospective observational study with a new load-distributing band chest compression device
    • 10.1016/j.resuscitation.2006.08.027 17254691
    • H Krep M Marnier M Breil U Heister M Fischer A Hoeft 2007 Out-of-hospital cardiopulmonary resuscitation with Autopulse system: a prospective observational study with a new load-distributing band chest compression device Resuscitation 73 86 95 10.1016/j.resuscitation.2006.08.027 17254691
    • (2007) Resuscitation , vol.73 , pp. 86-95
    • Krep, H.1    Marnier, M.2    Breil, M.3    Heister, U.4    Fischer, M.5    Hoeft, A.6
  • 13
    • 0033584459 scopus 로고    scopus 로고
    • A comparison of standard cardiopulmonary resuscitation and active compression-decompression resuscitation for out-of-hospital cardiac arrest. French active compression-decompression cardiopulmonary resuscitation study group
    • 10.1056/NEJM199908193410804
    • P Plaisance KG Lurie E Vicaut F Adnet JL Petit D Epain P Ecollan R Gruat P Cavagna J Biens D Payen 1999 A comparison of standard cardiopulmonary resuscitation and active compression-decompression resuscitation for out-of-hospital cardiac arrest. French active compression-decompression cardiopulmonary resuscitation study group N Engl J Med 31 569 575 10.1056/NEJM199908193410804
    • (1999) N Engl J Med , vol.31 , pp. 569-575
    • Plaisance, P.1    Lurie, K.G.2    Vicaut, E.3    Adnet, F.4    Petit, J.L.5    Epain, D.6    Ecollan, P.7    Gruat, R.8    Cavagna, P.9    Biens, J.10    Payen, D.11
  • 15
    • 0029977099 scopus 로고    scopus 로고
    • End-tidal carbon dioxide during cardiopulmonary resuscitation in humans presenting mostly with asystole: A predictor of outcome
    • 10.1097/00003246-199605000-00011 1:STN:280:DyaK28zitVKmtA%3D%3D 8706455
    • JP Cantineau Y Lambert P Merckx P Reynaud F Porte C Bertrand P Duvaldestin 1996 End-tidal carbon dioxide during cardiopulmonary resuscitation in humans presenting mostly with asystole: a predictor of outcome Crit Care Med 24 791 796 10.1097/00003246-199605000-00011 1:STN:280:DyaK28zitVKmtA%3D%3D 8706455
    • (1996) Crit Care Med , vol.24 , pp. 791-796
    • Cantineau, J.P.1    Lambert, Y.2    Merckx, P.3    Reynaud, P.4    Porte, F.5    Bertrand, C.6    Duvaldestin, P.7
  • 16
    • 79957646502 scopus 로고    scopus 로고
    • Effect of the addition of vasopressin, or vasopressin plus nitroglycerine to epinephrine on arterial blood pressure during cardiopulmonary resuscitation in human
    • in press
    • Ducros L, Vicaut E, Soleil C, Lurie KG, Plaisance P, Payen D (2010) Effect of the addition of vasopressin, or vasopressin plus nitroglycerine to epinephrine on arterial blood pressure during cardiopulmonary resuscitation in human. J Emerg Med (in press)
    • (2010) J Emerg Med
    • Ducros, L.1    Vicaut, E.2    Soleil, C.3    Lurie, K.G.4    Plaisance, P.5    Payen, D.6
  • 17
    • 36549000290 scopus 로고    scopus 로고
    • Improved neurological outcome with continuous chest compressions compared with 30:2 compressions-to-ventilations cardiopulmonary resuscitation in a realistic swine model of out-of-hospital cardiac arrest
    • 10.1161/CIRCULATIONAHA.107.711820 17998457
    • GA Ewy M Zuercher RW Hilwig AB Sanders RA Berg CW Otto MM Hayes KB Kern 2007 Improved neurological outcome with continuous chest compressions compared with 30:2 compressions-to-ventilations cardiopulmonary resuscitation in a realistic swine model of out-of-hospital cardiac arrest Circulation 116 2525 2530 10.1161/CIRCULATIONAHA.107.711820 17998457
    • (2007) Circulation , vol.116 , pp. 2525-2530
    • Ewy, G.A.1    Zuercher, M.2    Hilwig, R.W.3    Sanders, A.B.4    Berg, R.A.5    Otto, C.W.6    Hayes, M.M.7    Kern, K.B.8
  • 18
    • 0023686103 scopus 로고
    • Myocardial perfusion pressure: A predictor of 24-hour survival during prolonged cardiac arrest in dogs
    • 10.1016/0300-9572(88)90111-6 1:STN:280:DyaL1M%2FosVWitQ%3D%3D 2849790
    • KB Kern GA Ewy WD Voorhees CF Babbs WA Tacker 1988 Myocardial perfusion pressure: a predictor of 24-hour survival during prolonged cardiac arrest in dogs Resuscitation 16 241 250 10.1016/0300-9572(88)90111-6 1:STN:280: DyaL1M%2FosVWitQ%3D%3D 2849790
    • (1988) Resuscitation , vol.16 , pp. 241-250
    • Kern, K.B.1    Ewy, G.A.2    Voorhees, W.D.3    Babbs, C.F.4    Tacker, W.A.5
  • 19
    • 0028080880 scopus 로고
    • The effect of ventilation on acid-base balance and oxygenation in low blood-flow states
    • 10.1097/00003246-199422110-00019 1:STN:280:DyaK2M%2FksVemsg%3D%3D 7956288
    • AH Idris E Straples DJ O'Brian RJ Melker KD Del Duca JL Falk 1994 The effect of ventilation on acid-base balance and oxygenation in low blood-flow states Crit Care Med 22 1827 1834 10.1097/00003246-199422110-00019 1:STN:280:DyaK2M%2FksVemsg%3D%3D 7956288
    • (1994) Crit Care Med , vol.22 , pp. 1827-1834
    • Idris, A.H.1    Straples, E.2    O'Brian, D.J.3    Melker, R.J.4    Del Duca, K.D.5    Falk, J.L.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.