메뉴 건너뛰기




Volumn 159, Issue 2, 2010, Pages 241-247

Analysis of the passivation layer by testing and modeling a cell impedance micro-sensor

Author keywords

Bio sensor Cell impedance Passivation layer Modeling Breast cancer

Indexed keywords

DISEASES; MICROSENSORS; PARAMETER ESTIMATION;

EID: 77954314387     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2009.12.036     Document Type: Article
Times cited : (11)

References (30)
  • 1
    • 0022559399 scopus 로고
    • Use of electric fields to monitor the dynamical aspect of cell behavior in tissue culture
    • I. Giaever, C. Keese, Use of electric fields to monitor the dynamical aspect of cell behavior in tissue culture, IEEE Transactions on Biomedical Engineering (1986) 242-247.
    • (1986) IEEE Transactions on Biomedical Engineering , pp. 242-247
    • Giaever, I.1    Keese, C.2
  • 2
    • 0026069780 scopus 로고
    • Electric measurements can be used to monitor the attachment and spreading of cells in tissue culture
    • P. Mitra, C. Keese, I. Giaever, Electric measurements can be used to monitor the attachment and spreading of cells in tissue culture, Biotechniques 11 (4) (1991) 504-510.
    • (1991) Biotechniques , vol.11 , Issue.4 , pp. 504-510
    • Mitra, P.1    Keese, C.2    Giaever, I.3
  • 3
    • 0028446185 scopus 로고
    • A biosensor that monitors cell morphology with electrical fields
    • C. Keese, et al., A biosensor that monitors cell morphology with electrical fields, IEEE Engineering in Medicine and Biology Magazine 13 (3) (1994) 402-408.
    • (1994) IEEE Engineering in Medicine and Biology Magazine , vol.13 , Issue.3 , pp. 402-408
    • Keese, C.1
  • 4
    • 0034714440 scopus 로고    scopus 로고
    • Electric cell-substrate impedance sensing (ECIS) as a noninvasive means to monitor the kinetics of cell spreading to artificial surfaces
    • J. Wegener, C. Keese, I. Giaever, Electric cell-substrate impedance sensing (ECIS) as a noninvasive means to monitor the kinetics of cell spreading to artificial surfaces, Experimental Cell Research 259 (1) (2000) 158-166.
    • (2000) Experimental Cell Research , vol.259 , Issue.1 , pp. 158-166
    • Wegener, J.1    Keese, C.2    Giaever, I.3
  • 5
    • 0028823011 scopus 로고
    • Impedance analysis of MDCK cells measured by electric cell-substrate impedance sensing
    • C. Lo, C. Keese, I. Giaever, Impedance analysis of MDCK cells measured by electric cell-substrate impedance sensing, Biophysical Journal 69 (6) (1995) 2800-2807.
    • (1995) Biophysical Journal , vol.69 , Issue.6 , pp. 2800-2807
    • Lo, C.1    Keese, C.2    Giaever, I.3
  • 7
    • 0031060703 scopus 로고    scopus 로고
    • Monitoring of cellular behaviour by impedance measurements on interdigitated electrode structures
    • R. Ehret, et al., Monitoring of cellular behaviour by impedance measurements on interdigitated electrode structures, Biosensors and Bioelectronics 12 (1) (1997) 29-41.
    • (1997) Biosensors and Bioelectronics , vol.12 , Issue.1 , pp. 29-41
    • Ehret, R.1
  • 8
    • 3142677892 scopus 로고    scopus 로고
    • Design and fabrication of a microimpedance biosensor for bacterial detection
    • S. Radke, E. Alocilja, Design and fabrication of a microimpedance biosensor for bacterial detection, IEEE Sensors Journal 4 (4) (2004) 434-440.
    • (2004) IEEE Sensors Journal , vol.4 , Issue.4 , pp. 434-440
    • Radke, S.1    Alocilja, E.2
  • 9
    • 27944483761 scopus 로고    scopus 로고
    • Development of active matrix biosensor array for cell screening, in Sensors
    • H. Xiaoqiu, et al., Development of active matrix biosensor array for cell screening, in Sensors, Proceedings of IEEE 1 (2004) 72-75.
    • (2004) Proceedings of IEEE , vol.1 , pp. 72-75
    • Xiaoqiu, H.1
  • 10
    • 27944442038 scopus 로고    scopus 로고
    • A microelectrode impedance method to measure interaction of cells, in Sensors
    • H.L. Gomes, et al., A microelectrode impedance method to measure interaction of cells, in Sensors, Proceedings of IEEE 2 (2004) 1011-1013.
    • (2004) Proceedings of IEEE , vol.2 , pp. 1011-1013
    • Gomes, H.L.1
  • 11
    • 58149234842 scopus 로고    scopus 로고
    • Impedance studies of bio-behavior and chemosensitivity of cancer cells by micro-electrode arrays
    • Q. Liu, et al., Impedance studies of bio-behavior and chemosensitivity of cancer cells by micro-electrode arrays, Biosensors and Bioelectronics 24 (5) (2009) 1305-1310.
    • (2009) Biosensors and Bioelectronics , vol.24 , Issue.5 , pp. 1305-1310
    • Liu, Q.1
  • 12
    • 25144445503 scopus 로고    scopus 로고
    • Galvanic decoupled sensor for monitoring biomass concentration during fermentation processes
    • M. Hofmann, et al., Galvanic decoupled sensor for monitoring biomass concentration during fermentation processes, Sensors & Actuators B: Chemical 111 (2005) 370-375.
    • (2005) Sensors & Actuators B: Chemical , vol.111 , pp. 370-375
    • Hofmann, M.1
  • 13
    • 33847301631 scopus 로고    scopus 로고
    • Galvanically decoupled impedance spectroscopy for biological high-throughput-screening in microtiter plates, in Sensors
    • M.C. Hofmann, et al., Galvanically decoupled impedance spectroscopy for biological high-throughput-screening in microtiter plates, in Sensors, IEEE Sensors (2005) 4.
    • (2005) IEEE Sensors , pp. 4
    • Hofmann, M.C.1
  • 14
    • 3042787961 scopus 로고    scopus 로고
    • Fibroblast growth and H-7 protein kinase inhibitor response monitored in microimpedance sensor arrays
    • D. Nguyen, et al., Fibroblast growth and H-7 protein kinase inhibitor response monitored in microimpedance sensor arrays, Biotechnology and Bioengineering 87 (2) (2004).
    • (2004) Biotechnology and Bioengineering , vol.87 , Issue.2
    • Nguyen, D.1
  • 16
    • 4544272295 scopus 로고    scopus 로고
    • Simulation of microelectrode impedance changes due to cell growth
    • X. Huang, et al., Simulation of microelectrode impedance changes due to cell growth, IEEE Sensors Journal 4 (5) (2004) 576-583.
    • (2004) IEEE Sensors Journal , vol.4 , Issue.5 , pp. 576-583
    • Huang, X.1
  • 17
    • 77954314561 scopus 로고    scopus 로고
    • A.I.o.C. Engineers, and meeting, impedance array studies of mammalian cell growth
    • D. Nguyen, A.I.o.C. Engineers, and Meeting, Impedance Array Studies of Mammalian Cell Growth, American Institute of Chemical Engineers, 2003.
    • (2003) American Institute of Chemical Engineers
    • Nguyen, D.1
  • 18
    • 1542303757 scopus 로고    scopus 로고
    • Impedance based biosensor array for monitoring mammalian cell behavior, in Sensors
    • X. Huang, et al., Impedance based biosensor array for monitoring mammalian cell behavior, in Sensors, Proceedings of IEEE Sensors 1 (2003) 304-309.
    • (2003) Proceedings of IEEE Sensors , vol.1 , pp. 304-309
    • Huang, X.1
  • 19
    • 11144312529 scopus 로고    scopus 로고
    • Evaluation of the electrical cell-substrate impedance sensing system (ECIS) method using a mathematical model
    • N. Goda, et al., Evaluation of the electrical cell-substrate impedance sensing system (ECIS) method using a mathematical model, in: MWSCAS- 04. The 2004 47th Midwest Symposium on Circuits and Systems, 2004.
    • (2004) MWSCAS- 04. The 2004 47th Midwest Symposium on Circuits and Systems
    • Goda, N.1
  • 20
    • 35548963931 scopus 로고    scopus 로고
    • Quantitative evaluation of micro-motion of vascular endothelial cells in electrical cell-substrate impedance sensing (ECIS) method using a precision mathematical model
    • N. Goda, et al., Quantitative evaluation of micro-motion of vascular endothelial cells in electrical cell-substrate impedance sensing (ECIS) method using a precision mathematical model, in: International Conference on Microtechnologies in Medicine and Biology, 2006.
    • (2006) International Conference on Microtechnologies in Medicine and Biology
    • Goda, N.1
  • 22
    • 33748675085 scopus 로고    scopus 로고
    • Amicro-electrode array biosensor for impedance spectroscopy of human umbilical vein endothelial cells
    • A. Rahman, C. Lo, S. Bhansali, Amicro-electrode array biosensor for impedance spectroscopy of human umbilical vein endothelial cells, Sensors & Actuators B: Chemical 118 (1-2) (2006) 115-120.
    • (2006) Sensors & Actuators B: Chemical , vol.118 , Issue.1-2 , pp. 115-120
    • Rahman, A.1    Lo, C.2    Bhansali, S.3
  • 23
    • 77954313991 scopus 로고    scopus 로고
    • Design rule for optimization of microelectrodes used in electric cell-substrate impedance sensing (ECIS)
    • D. Price, A. Rahman, S. Bhansali, Design rule for optimization of microelectrodes used in electric cell-substrate impedance sensing (ECIS), Biosensors and Bioelectronics (2008).
    • (2008) Biosensors and Bioelectronics
    • Price, D.1    Rahman, A.2    Bhansali, S.3
  • 24
    • 0003899669 scopus 로고    scopus 로고
    • Cell based biosensors using microelectrodes
    • Stanford University, Palo Alto, CA
    • D. Borkholder, Cell based biosensors using microelectrodes, in: Electrical Engineering, Stanford University, Palo Alto, CA, 1998.
    • (1998) Electrical Engineering
    • Borkholder, D.1
  • 26
    • 0141984757 scopus 로고    scopus 로고
    • HP LF 4192A impedance analyzer
    • H. Packard, HP LF 4192A impedance analyzer, Operation Manual (1996).
    • (1996) Operation Manual
    • Packard, H.1
  • 28
    • 77951017313 scopus 로고    scopus 로고
    • Electrochemical models for electrode behavior in retinal prostheses. M. Eng, thesis, massachusetts institute of technology
    • Roach, K., Electrochemical models for electrode behavior in retinal prostheses. M. Eng, Thesis, Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science (2003).
    • (2003) Department of Electrical Engineering and Computer Science
    • Roach, K.1
  • 30
    • 36348988055 scopus 로고    scopus 로고
    • Fitting models to biological data using linear and nonlinear regression. A practical guide to curve fitting
    • 4.0 ed. SanDiego, CA
    • H.J. Motulsky, A. Christopolous, Fitting Models to Biological Data using Linear and Nonlinear Regression. A Practical Guide to Curve Fitting, 4.0 ed., GraphPad Software Inc., SanDiego, CA, 2003.
    • (2003) GraphPad Software Inc.
    • Motulsky, H.J.1    Christopolous, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.