메뉴 건너뛰기




Volumn 11, Issue 1, 2010, Pages 24-32

Acrylonitrile Butadiene Styrene (ABS) plastic-based low cost tissue equivalent phantom for verification dosimetry in IMRT

Author keywords

ABS; Dose verification; IMRT; Phantom

Indexed keywords


EID: 77954292459     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v11i1.3030     Document Type: Article
Times cited : (35)

References (21)
  • 3
    • 12144289319 scopus 로고    scopus 로고
    • Implementing IMRT in clinical practice: a joint document of the American Society for Therapeutic Radiology and Oncology and the American Association of Physicists in Medicine
    • Galvin JM, Ezzell G, Eisbrauch A, et al. Implementing IMRT in clinical practice: a joint document of the American Society for Therapeutic Radiology and Oncology and the American Association of Physicists in Medicine. Int J Radiat Oncol Biol Phys. 2004;58(5):1616-34.
    • (2004) Int J Radiat Oncol Biol Phys , vol.58 , Issue.5 , pp. 1616-1634
    • Galvin, J.M.1    Ezzell, G.2    Eisbrauch, A.3
  • 4
    • 77954297863 scopus 로고    scopus 로고
    • Medical Physics Monograph No. 29. 2003 AAPM Summer School Proceedings. Madison (WI): Medical Physics Publishing; Palta JR, Mackie TR, editors
    • Palta JR, Mackie TR, editors. Intensity-Modulated Radiation Therapy: The State of the Art. Medical Physics Monograph No. 29. 2003 AAPM Summer School Proceedings. Madison (WI): Medical Physics Publishing; 2003.
    • (2003) Intensity-Modulated Radiation Therapy: The State of the Art
  • 5
    • 0036570270 scopus 로고    scopus 로고
    • Intensity-modulated radiotherapy of head-and-neck cancer: encouraging early results
    • Eisbruch A. Intensity-modulated radiotherapy of head-and-neck cancer: encouraging early results. Int J Radiat Oncol Biol Phys. 2002;53(1):1-3.
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , Issue.1 , pp. 1-3
    • Eisbruch, A.1
  • 6
    • 0034212772 scopus 로고    scopus 로고
    • Clinical experience with intensity modulated radiation therapy (IMRT) in prostate cancer
    • Zelefsky MJ, Fuks Z, Happersett L, et al. Clinical experience with intensity modulated radiation therapy (IMRT) in prostate cancer. Radiother Oncol. 2000;55(3):241-49.
    • (2000) Radiother Oncol , vol.55 , Issue.3 , pp. 241-249
    • Zelefsky, M.J.1    Fuks, Z.2    Happersett, L.3
  • 7
    • 0344530449 scopus 로고    scopus 로고
    • IMRT: delivery techniques and quality assurance
    • Williams PC. IMRT: delivery techniques and quality assurance. Br J Radiol. 2003;76(911):766-76.
    • (2003) Br J Radiol , vol.76 , Issue.911 , pp. 766-776
    • Williams, P.C.1
  • 8
    • 0035577194 scopus 로고    scopus 로고
    • The effect of setup uncertainty on normal tissue sparing with IMRT for head-and-neck cancer
    • Manning M A, Wu Q, Cardinale RM, et al. The effect of setup uncertainty on normal tissue sparing with IMRT for head-and-neck cancer. Int J Radiat Oncol Biol Phys. 2001;51(5):1400-09.
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , Issue.5 , pp. 1400-1409
    • Manning, M.A.1    Wu, Q.2    Cardinale, R.M.3
  • 10
    • 25844468645 scopus 로고    scopus 로고
    • An inter-centre quality assurance network for IMRT verification: results of the ESTRO QUASIMODO project
    • Gillis S, De Wagter C, Bohsung J, Perrin B, Williams P, Mijnheer BJ. An inter-centre quality assurance network for IMRT verification: results of the ESTRO QUASIMODO project. Radiother Oncol. 2005;76(3):340-53.
    • (2005) Radiother Oncol , vol.76 , Issue.3 , pp. 340-353
    • Gillis, S.1    De Wagter, C.2    Bohsung, J.3    Perrin, B.4    Williams, P.5    Mijnheer, B.J.6
  • 11
    • 33750729320 scopus 로고    scopus 로고
    • Dosimetric pre-treatment verification of IMRT using an EPID: clinical experience
    • van Zijtveld M, Dirkx MLP, de Boer HJC, Heijmen BJM. Dosimetric pre-treatment verification of IMRT using an EPID: clinical experience. Radiother Oncol. 2006;81(12):168-75.
    • (2006) Radiother Oncol. , vol.81 , Issue.12 , pp. 168-175
    • van Zijtveld, M.1    Dirkx, M.L.P.2    de Boer, H.J.C.3    Heijmen, B.J.M.4
  • 12
    • 0033854663 scopus 로고    scopus 로고
    • Intensity modulated radiotherapy dose delivery error from radiation field offset inaccuracy
    • Kung JH, Chen GT. Intensity modulated radiotherapy dose delivery error from radiation field offset inaccuracy. Med Phys. 2000;27(7):1617-22.
    • (2000) Med Phys , vol.27 , Issue.7 , pp. 1617-1622
    • Kung, J.H.1    Chen, G.T.2
  • 13
    • 24944537076 scopus 로고    scopus 로고
    • Design and implementation of an anthropomorphic quality assurance phantom for intensity-modulated radiation therapy for the Radiation Therapy Oncology Group
    • Molineu A, Followill DS, Balter PA, et al. Design and implementation of an anthropomorphic quality assurance phantom for intensity-modulated radiation therapy for the Radiation Therapy Oncology Group. Int J Radiat Oncol Biol Phys. 2005;63(2):577-83.
    • (2005) Int J Radiat Oncol Biol Phys , vol.63 , Issue.2 , pp. 577-583
    • Molineu, A.1    Followill, D.S.2    Balter, P.A.3
  • 14
    • 0032520945 scopus 로고    scopus 로고
    • Phantoms for IMRT dose distribution measurement and treatment verification
    • Low DA, Gerber RL, Mutic S, Purdy JA. Phantoms for IMRT dose distribution measurement and treatment verification. Int J RadiatOncol Biol Phys. 1998;40(5):1231-35.
    • (1998) Int J RadiatOncol Biol Phys , vol.40 , Issue.5 , pp. 1231-1235
    • Low, D.A.1    Gerber, R.L.2    Mutic, S.3    Purdy, J.A.4
  • 15
    • 85024383143 scopus 로고    scopus 로고
    • Benchmark™ IMRT QA Phantom. Available from
    • Benchmark™ IMRT QA Phantom. Available from: http://civco.com/oncology/physics/phantom/benchmark/
  • 16
    • 85024380149 scopus 로고    scopus 로고
    • Computerized Imaging Reference Systems, Inc. Norfolk, VA, USA. Available from
    • Computerized Imaging Reference Systems, Inc. Norfolk, VA, USA. Available from: http://www.cirsinc.com/main_radiation.html
  • 17
    • 85024362557 scopus 로고    scopus 로고
    • IBA Dosimetry AB, Uppsala, Sweden Available from
    • IBA Dosimetry AB, Uppsala, Sweden Available from: http://www.iba-dosimetry.com/complete-solutions/radiotherapy/imrt-igrt-rotational-qa/i-mrt-phantom
  • 18
    • 85024393596 scopus 로고    scopus 로고
    • Standard Imaging; Middleton, WI, USA. Available from
    • Standard Imaging; Middleton, WI, USA. Available from: http://www.standardimaging.com/product_home.php?id=37
  • 19
    • 0003682469 scopus 로고
    • ICRU Report 44. Bethesda (MD): ICRU; International Commission on Radiation Units and Measurements
    • International Commission on Radiation Units and Measurements. Tissue substitutes in radiation dosimetry and measurements. ICRU Report 44. Bethesda (MD): ICRU; 1989.
    • (1989) Tissue substitutes in radiation dosimetry and measurements
  • 21
    • 63649119703 scopus 로고    scopus 로고
    • Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry
    • Ferreira BC, Lopes MC, Capela M. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry. Phys Med Biol. 2009;54(4):1073-85.
    • (2009) Phys Med Biol , vol.54 , Issue.4 , pp. 1073-1085
    • Ferreira, B.C.1    Lopes, M.C.2    Capela, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.