메뉴 건너뛰기




Volumn 13, Issue 1, 2010, Pages 41-46

Breath sampling control for medical application

Author keywords

Breath analysis; Carbon dioxide; End tidal volume; Expiration; Humidity; Inspiration; Ion mobility spectrometry; Tidal volume

Indexed keywords

AUTOMATED CONTROL; BREATH ANALYSIS; CHEMICAL DETERMINATION; EXPIRATION; FLOW-SENSORS; HUMAN CONTROL; HUMAN SUBJECTS; ION MOBILITY SPECTROMETRY; MULTI-CAPILLARY COLUMNS; SENSOR SIGNALS; THRESHOLD SETTING; TIDAL VOLUME; UPPER AIRWAY;

EID: 77954087429     PISSN: 14356163     EISSN: 18654584     Source Type: Journal    
DOI: 10.1007/s12127-010-0039-4     Document Type: Article
Times cited : (28)

References (17)
  • 1
    • 33749016240 scopus 로고    scopus 로고
    • Current status of clinical breath analysis
    • Risby TH, Solga SF (2006) Current status of clinical breath analysis. Appl Phys B Lasers Opt 85: 421-426.
    • (2006) Appl Phys B Lasers Opt , vol.85 , pp. 421-426
    • Risby, T.H.1    Solga, S.F.2
  • 2
    • 21544476745 scopus 로고    scopus 로고
    • Breath analysis
    • Zolotov YA (2005) Breath analysis. J Anal Chem 60: 497.
    • (2005) J Anal Chem , vol.60 , pp. 497
    • Zolotov, Y.A.1
  • 3
    • 73949096027 scopus 로고    scopus 로고
    • Breath analysis-performance and potential of ion mobility spectrometry
    • 036004, doi: 10. 1088/1752-7155/3/3/036004
    • Vautz W, Nolte J, Fobbe R, Baumbach JI (2009) Breath analysis-performance and potential of ion mobility spectrometry. J Breath Res 3, 036004 (8pp) doi: 10. 1088/1752-7155/3/3/036004.
    • (2009) J Breath Res , vol.3 , pp. 8
    • Vautz, W.1    Nolte, J.2    Fobbe, R.3    Baumbach, J.I.4
  • 4
    • 33745281142 scopus 로고    scopus 로고
    • Ion mobility spectrometry: A new method for the detection of lung cancer and airway infection in exhaled air-first results of a pilot study
    • Westhoff M (2005) Ion mobility spectrometry: a new method for the detection of lung cancer and airway infection in exhaled air-first results of a pilot study. Chest 128: 155S.
    • (2005) Chest , vol.128
    • Westhoff, M.1
  • 5
    • 33846356443 scopus 로고    scopus 로고
    • Ion mobility spectrometry to detect lung cancer and airway infections
    • Baumbach JI, Westhoff M (2006) Ion mobility spectrometry to detect lung cancer and airway infections. Spectrosc Eur 18: 22-27.
    • (2006) Spectrosc Eur , vol.18 , pp. 22-27
    • Baumbach, J.I.1    Westhoff, M.2
  • 6
    • 40449107205 scopus 로고    scopus 로고
    • Ion mobility spectrometry in the diagnosis of sarcoidosis results of a feasibility study
    • Westhoff M, Litterst P, Freitag L, Baumbach JI (2007) Ion mobility spectrometry in the diagnosis of sarcoidosis results of a feasibility study. J Physiol Pharmacol 58: 739-751.
    • (2007) J Physiol Pharmacol , vol.58 , pp. 739-751
    • Westhoff, M.1    Litterst, P.2    Freitag, L.3    Baumbach, J.I.4
  • 7
    • 69749091957 scopus 로고    scopus 로고
    • Ion mobility spectrometry for the detection of volatile organic compounds in exhaled breath of lung cancer patients-results of a pilot study
    • 2008
    • Westhoff M (2008) Ion mobility spectrometry for the detection of volatile organic compounds in exhaled breath of lung cancer patients-results of a pilot study. Thorax 64: 2008.
    • (2008) Thorax , vol.64
    • Westhoff, M.1
  • 8
    • 71749099575 scopus 로고    scopus 로고
    • Determination of serum propofol concentrations by breath analysis using ion mobility spectrometry
    • Perl T, Carstens ETH, Hirn A, Quintel M, Vautz W, Nolte J, Jünger M (2009) Determination of serum propofol concentrations by breath analysis using ion mobility spectrometry. Br J Anaesthesia 103(6): 822-827.
    • (2009) Br J Anaesthesia , vol.103 , Issue.6 , pp. 822-827
    • Perl, T.1    Carstens, E.T.H.2    Hirn, A.3    Quintel, M.4    Vautz, W.5    Nolte, J.6    Jünger, M.7
  • 12
    • 0344668784 scopus 로고    scopus 로고
    • Real-time breath monitoring of propofol and its volatile metabolites during surgery using a novel mass spectrometric technique: A feasibility study
    • Harrison GR, Critchley AD, Mayhew CA, Thompson JM (2003) Real-time breath monitoring of propofol and its volatile metabolites during surgery using a novel mass spectrometric technique: a feasibility study. Br J Anaesth 91: 797-799.
    • (2003) Br J Anaesth , vol.91 , pp. 797-799
    • Harrison, G.R.1    Critchley, A.D.2    Mayhew, C.A.3    Thompson, J.M.4
  • 15
    • 33947418422 scopus 로고    scopus 로고
    • Determination of volatile products of human colon cell line metabolism by GC/MS analysis
    • Zimmermann D, Hartmann M, Moyer MP, Nolte J, Baumbach JI (2007) Determination of volatile products of human colon cell line metabolism by GC/MS analysis. Metabolomics 3: 13-17.
    • (2007) Metabolomics , vol.3 , pp. 13-17
    • Zimmermann, D.1    Hartmann, M.2    Moyer, M.P.3    Nolte, J.4    Baumbach, J.I.5
  • 17
    • 73949110597 scopus 로고    scopus 로고
    • HovaCAL®-a generator for multi-component humid calibration gases
    • Vautz W, Schmäh M (2009) HovaCAL®-a generator for multi-component humid calibration gases. Int J Ion Mobil Spec 12: 139-147.
    • (2009) Int J Ion Mobil Spec , vol.12 , pp. 139-147
    • Vautz, W.1    Schmäh, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.