Volumn 12, Issue 6, 2010, Pages 613-618

The effect of patient age on the internal carotid artery location around the atlas: Clinical article

Author keywords

C 1 lateral mass screw; Internal carotid artery; Vessel tortuosity

Indexed keywords

ADULT; AGE; AGE DISTRIBUTION; AGED; ARTERY INJURY; ARTICLE; ATLAS; BONE SCREW; CLINICAL EVALUATION; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTROLLED STUDY; CORTICAL BONE; FEMALE; HUMAN; INCIDENCE; INTERNAL CAROTID ARTERY; LONGUS CAPITIS MUSCLE; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; MUSCLE ATROPHY; NECK MUSCLE; PREVALENCE; SENESCENCE; SPINE SURGERY;

EID: 77953945845     PISSN: 15475654     EISSN: 15475646     Source Type: Journal    
DOI: 10.3171/2010.1.SPINE09409     Document Type: Article
Times cited : (24)

References (21)
  • 1
    • 0018101951 scopus 로고
    • Age-related changes in the colonic blood supply: Their relevance to ischaemic colitis
    • Binns JC, Isaacson P: Age-related changes in the colonic blood supply: their relevance to ischaemic colitis. Gut 19:384-390, 1978
    • (1978) Gut , vol.19 , pp. 384-390
    • Binns, J.C.1    Isaacson, P.2
  • 2
    • 34247526494 scopus 로고    scopus 로고
    • Iatrogenic perforation of the internal carotid artery by a transarticular screw: An unusual case of repetitive ischemic stroke
    • DOI 10.1016/j.clineuro.2007.02.008, PII S0303846707000492
    • Bogaerde MV, Viaene P, Thijs V: Iatrogenic perforation of the internal carotid artery by a transarticular screw: an unusual case of repetitive ischemic stroke. Clin Neurol Neurosurg 109:466-469, 2007 (Pubitemid 46660334)
    • (2007) Clinical Neurology and Neurosurgery , vol.109 , Issue.5 , pp. 466-469
    • Bogaerde, M.V.1    Viaene, P.2    Thijs, V.3
  • 3
    • 71549166348 scopus 로고    scopus 로고
    • The effects of healthy aging on intracerebral blood vessels visualized by magnetic resonance angiography
    • Bullitt E, Zeng D, Mortamet B, Ghosh A, Aylward SR, Lin W, et al: The effects of healthy aging on intracerebral blood vessels visualized by magnetic resonance angiography. Neurobiol Aging 31:290-300, 2010
    • (2010) Neurobiol Aging , vol.31 , pp. 290-300
    • Bullitt, E.1    Zeng, D.2    Mortamet, B.3    Ghosh, A.4    Aylward, S.R.5    Lin, W.6
  • 5
    • 41349107181 scopus 로고    scopus 로고
    • Relationship of the internal carotid artery to the anterior aspect of the C1 vertebra: Implications for C1-C2 transarticular and C1 lateral mass fixation
    • Currier BL, Maus TP, Eck JC, Larson DR, Yaszemski MJ: Relationship of the internal carotid artery to the anterior aspect of the C1 vertebra: implications for C1-C2 transarticular and C1 lateral mass fixation. Spine 33:635-639, 2008
    • (2008) Spine , vol.33 , pp. 635-639
    • Currier, B.L.1    Maus, T.P.2    Eck, J.C.3    Larson, D.R.4    Yaszemski, M.J.5
  • 6
    • 2442579305 scopus 로고    scopus 로고
    • Anatomic relationship of the internal carotid artery to the C1 vertebra: A case report of cervical reconstruction for chordoma and pilot study to assess the risk of screw fixation of the atlas
    • Currier BL, Todd LT, Maus TP, Fisher DR, Yaszemski MJ: Anatomic relationship of the internal carotid artery to the C1 vertebra: A case report of cervical reconstruction for chordoma and pilot study to assess the risk of screw fixation of the atlas. Spine 28:E461-E467, 2003
    • (2003) Spine , vol.28
    • Currier, B.L.1    Todd, L.T.2    Maus, T.P.3    Fisher, D.R.4    Yaszemski, M.J.5
  • 7
    • 45949090876 scopus 로고    scopus 로고
    • Fixation strength of unicortical versus bicortical C1-C2 transarticular screws
    • DOI 10.1016/j.spinee.2007.02.008, PII S152994300700109X
    • Cyr SJ, Currier BL, Eck JC, Foy A, Chen Q, Larson DR, et al: Fixation strength of unicortical versus bicortical C1-C2 transarticular screws. Spine J 8:661-665, 2008 (Pubitemid 351893125)
    • (2008) Spine Journal , vol.8 , Issue.4 , pp. 661-665
    • Cyr, S.J.1    Currier, B.L.2    Eck, J.C.3    Foy, A.4    Chen, Q.5    Larson, D.R.6    Yaszemski, M.J.7    An, K.-N.8
  • 9
    • 0034128001 scopus 로고    scopus 로고
    • The optimal transarticular C1-2 screw length and the location of the hypoglossal nerve
    • DOI 10.1016/S0090-3019(00)00160-9, PII S0090301900001609
    • Ebraheim NA, Misson JR, Xu R, Yeasting RA: The optimal transarticular c1-2 screw length and the location of the hypoglossal nerve. Surg Neurol 53:208-210, 2000 (Pubitemid 30201523)
    • (2000) Surgical Neurology , vol.53 , Issue.3 , pp. 208-210
    • Ebraheim, N.A.1    Misson, J.R.2    Xu, R.3    Yeasting, R.A.4
  • 10
    • 58149159903 scopus 로고    scopus 로고
    • Techniques of posterior C1-C2 stabilization
    • Goel A: Techniques of posterior C1-C2 stabilization. Neurosurgery 62:E1384, 2008
    • (2008) Neurosurgery , vol.62
    • Goel, A.1
  • 11
    • 0035890208 scopus 로고    scopus 로고
    • Posterior C1-C2 fusion with polyaxial screw and rod fixation
    • DOI 10.1097/00007632-200111150-00014
    • Harms J, Melcher RP: Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine 26:2467-2471, 2001 (Pubitemid 33065058)
    • (2001) Spine , vol.26 , Issue.22 , pp. 2467-2471
    • Harms, J.1    Melcher, R.P.2
  • 12
    • 41749124565 scopus 로고    scopus 로고
    • Anatomical relationship of the internal carotid artery to C-1: Clinical implications for screw fixation of the atlas
    • DOI 10.3171/SPI/2008/8/4/335
    • Hoh DJ, Maya M, Jung A, Ponrartana S, Lauryssen CL: Anatomical relationship of the internal carotid artery to C-1: clinical implications for screw fixation of the atlas. J Neurosurg Spine 8:335-340, 2008 (Pubitemid 351489558)
    • (2008) Journal of Neurosurgery: Spine , vol.8 , Issue.4 , pp. 335-340
    • Hoh, D.J.1    Maya, M.2    Jung, A.3    Ponrartana, S.4    Lauryssen, C.L.5
  • 13
    • 34548252787 scopus 로고    scopus 로고
    • Hypoglossal nerve palsy after posterior screw placement on the C-1 lateral mass. Case report
    • Hong JT, Lee SW, Son BC, Sung JH, Kim IS, Park CK: Hypoglossal nerve palsy after posterior screw placement on the C-1 lateral mass. Case report. J Neurosurg Spine 5:83-85, 2006
    • (2006) J Neurosurg Spine , vol.5 , pp. 83-85
    • Hong, J.T.1    Lee, S.W.2    Son, B.C.3    Sung, J.H.4    Kim, I.S.5    Park, C.K.6
  • 14
    • 41049109242 scopus 로고    scopus 로고
    • Analysis of anatomical variations of bone and vascular structures around the posterior atlantal arch using three-dimensional computed tomography angiography
    • Hong JT, Lee SW, Son BC, Sung JH, Yang SH, Kim IS, et al: Analysis of anatomical variations of bone and vascular structures around the posterior atlantal arch using three-dimensional computed tomography angiography. J Neurosurg Spine 8:230-236, 2008
    • (2008) J Neurosurg Spine , vol.8 , pp. 230-236
    • Hong, J.T.1    Lee, S.W.2    Son, B.C.3    Sung, J.H.4    Yang, S.H.5    Kim, I.S.6
  • 16
    • 53649083879 scopus 로고    scopus 로고
    • Insertion of lateral mass screw of the atlas via the posterior arch: Anatomical study of screw insertion using dry bone samples of the atlas from Japanese cadavers
    • Kobayashi Y, Kikuchi S, Konno S, Sekiguchi M: Insertion of lateral mass screw of the atlas via the posterior arch: anatomical study of screw insertion using dry bone samples of the atlas from Japanese cadavers. J Orthop Sci 13:452-455, 2008
    • (2008) J Orthop Sci , vol.13 , pp. 452-455
    • Kobayashi, Y.1    Kikuchi, S.2    Konno, S.3    Sekiguchi, M.4
  • 18
    • 64749096163 scopus 로고    scopus 로고
    • C1 pedicle screws versus C1 lateral mass screws: Comparisons of pullout strengths and biomechanical stabilities
    • Ma XY, Yin QS, Wu ZH, Xia H, Liu JF, Xiang M, et al: C1 pedicle screws versus C1 lateral mass screws: comparisons of pullout strengths and biomechanical stabilities. Spine 34: 371-377, 2009
    • (2009) Spine , vol.34 , pp. 371-377
    • Ma, X.Y.1    Yin, Q.S.2    Wu, Z.H.3    Xia, H.4    Liu, J.F.5    Xiang, M.6
  • 21
    • 62149089245 scopus 로고    scopus 로고
    • Posterior reduction and fixation of an unstable Jefferson fracture with C1 lateral mass screws, C2 isthmus screws, and crosslink fixation: Technical case report
    • ONSE100-ONSE101
    • Tessitore E, Momjian A, Payer M: Posterior reduction and fixation of an unstable Jefferson fracture with C1 lateral mass screws, C2 isthmus screws, and crosslink fixation: technical case report. Neurosurgery 63 (1 Suppl):ONSE100-ONSE101, 2008
    • (2008) Neurosurgery , vol.63 , Issue.1 SUPPL.
    • Tessitore, E.1    Momjian, A.2    Payer, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.