Energy-efficient air cooling of data centers at 2000 W/ft2

Author keywords

[No Author keywords available]

Indexed keywords

AIR COOLING; AIR FLOW MANAGEMENT; BEST PRACTICE; CAPITAL COSTS; COMPUTATIONAL FLUID DYNAMICS MODELING; CURRENT TECHNOLOGY; DATA CENTER COOLING; DATA CENTERS; DESIGN CONSIDERATIONS; ENERGY EFFICIENT; ENERGY-EFFICIENT DESIGN; HEAT DENSITY; HIGH-DENSITY; HOT AIRFLOW; INFORMATION AND COMMUNICATIONS TECHNOLOGY; KEY FACTORS; KEY PARTS; NEW DESIGN; OPERATIONAL COSTS; SERVER PLATFORM; THERMAL MANAGEMENT; TOTAL COST OF OWNERSHIP;

EID: 77953933787     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (1)

References (9)
  • 1
    • 77952814564 scopus 로고    scopus 로고
    • Data Center TCO: A comparison of high-density and low-density spaces
    • Santa Fe, NM, January 7-10
    • Patterson, M.K., et.al. Data Center TCO: A comparison of high-density and low-density spaces. THERMES 2007, Santa Fe, NM, January 7-10, 2007.
    • (2007) THERMES 2007
    • Patterson, M.K.1
  • 2
    • 4344572635 scopus 로고    scopus 로고
    • ASHRAE. Special Publication, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA
    • ASHRAE. 2004. Special Publication, Thermal Guidelines for Data Processing Environments. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA.
    • (2004) Thermal Guidelines for Data Processing Environments
  • 3
    • 4344572635 scopus 로고    scopus 로고
    • ASHRAE. Special Publication, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA
    • ASHRAE. 2009. Special Publication, Thermal Guidelines for Data Processing Environments. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA.
    • (2009) Thermal Guidelines for Data Processing Environments
  • 4
    • 77953928878 scopus 로고    scopus 로고
    • Telcordia. Thermal Management in Telecommunications Central Offices, December 2001, Telcordia Technologies, Inc., Piscataway, NJ
    • Telcordia. 2001. (Herrlin, M. K.) Generic Requirements NEBS GR-3028-CORE, Thermal Management in Telecommunications Central Offices, Issue 1, December 2001, Telcordia Technologies, Inc., Piscataway, NJ.
    • (2001) Generic Requirements NEBS GR-3028-CORE , Issue.1
    • Herrlin, M.K.1
  • 5
    • 77953934180 scopus 로고    scopus 로고
    • United States: Data Center Infrastructure Trends and Market Analysis, April
    • Data Center Dynamics, United States: Data Center Infrastructure Trends and Market Analysis, April 2008.
    • (2008) Data Center Dynamics
  • 6
    • 29144450886 scopus 로고    scopus 로고
    • Rack Cooling Effectiveness in Data Centers and Telecom Central Offices: The Rack Cooling Index (RCI)
    • American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA
    • Herrlin, M. K. 2005. Rack Cooling Effectiveness in Data Centers and Telecom Central Offices: The Rack Cooling Index (RCI). ASHRAE Transactions, Volume 111, Part 2, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA.
    • (2005) ASHRAE Transactions , vol.111 , Issue.PART 2
    • Herrlin, M.K.1
  • 8
  • 9
    • 77953946467 scopus 로고    scopus 로고
    • Airflow and Cooling Performance of Data Centers: Two Performance Metrics
    • American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA
    • Herrlin, M. K. 2008. Airflow and Cooling Performance of Data Centers: Two Performance Metrics. ASHRAE Transactions, Volume 114, Part 2, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA.
    • (2008) ASHRAE Transactions , vol.114 , Issue.PART 2
    • Herrlin, M.K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.