-
1
-
-
0026987256
-
Field test of vertical ground-coupled heat pump in Alabama
-
Kavanaugh S.P. Field test of vertical ground-coupled heat pump in Alabama. ASHRAE Trans 98 (1992) 607-616
-
(1992)
ASHRAE Trans
, vol.98
, pp. 607-616
-
-
Kavanaugh, S.P.1
-
2
-
-
0344118171
-
Energy and exergy analysis of a ground source (geothermal) heat pump system
-
Hepbasli A., and Akdemir O. Energy and exergy analysis of a ground source (geothermal) heat pump system. Energy Convers Manage 45 (2004) 737-753
-
(2004)
Energy Convers Manage
, vol.45
, pp. 737-753
-
-
Hepbasli, A.1
Akdemir, O.2
-
3
-
-
54949088658
-
Experiment performance evaluation of a closed-loop vertical ground source heat pump in the heating mode using energy analysis method
-
Kara Y.A. Experiment performance evaluation of a closed-loop vertical ground source heat pump in the heating mode using energy analysis method. Int J Energy Res 31 (2007) 1504-1516
-
(2007)
Int J Energy Res
, vol.31
, pp. 1504-1516
-
-
Kara, Y.A.1
-
4
-
-
0035421287
-
A performance comparison between an air-source and a ground-source reversible heat pump
-
De Swardt C.A., and Meyer J.P. A performance comparison between an air-source and a ground-source reversible heat pump. Int J Energy Res 25 (2001) 899-910
-
(2001)
Int J Energy Res
, vol.25
, pp. 899-910
-
-
De Swardt, C.A.1
Meyer, J.P.2
-
5
-
-
48849105904
-
Comparison between the energy performance of a ground coupled water to water heat pump system and an air to water heat pump system for heating and cooling in typical conditions of the European Mediterranean coast
-
Urchueguia J.F., Zacares M., Corberan J.M., Montero A., Martos J., and Witte H. Comparison between the energy performance of a ground coupled water to water heat pump system and an air to water heat pump system for heating and cooling in typical conditions of the European Mediterranean coast. Energy Convers Manage 49 (2008) 2917-2923
-
(2008)
Energy Convers Manage
, vol.49
, pp. 2917-2923
-
-
Urchueguia, J.F.1
Zacares, M.2
Corberan, J.M.3
Montero, A.4
Martos, J.5
Witte, H.6
-
6
-
-
0037175089
-
Performance evaluation of a vertical ground-source heat pump system in Izmir, Turkey
-
Hepbasli A. Performance evaluation of a vertical ground-source heat pump system in Izmir, Turkey. Int J Energy Res 26 (2002) 1121-1139
-
(2002)
Int J Energy Res
, vol.26
, pp. 1121-1139
-
-
Hepbasli, A.1
-
7
-
-
0037332319
-
Experimental study of a closed loop vertical ground source heat pump system
-
Hepbasli A., Akdemir O., and Hancioglu E. Experimental study of a closed loop vertical ground source heat pump system. Energy Convers Manage 44 (2003) 527-548
-
(2003)
Energy Convers Manage
, vol.44
, pp. 527-548
-
-
Hepbasli, A.1
Akdemir, O.2
Hancioglu, E.3
-
8
-
-
20444471567
-
Thermodynamic analysis of a ground-source heat pump system for district heating
-
Hepbasli A. Thermodynamic analysis of a ground-source heat pump system for district heating. Int J Energy Res 7 (2005) 671-687
-
(2005)
Int J Energy Res
, vol.7
, pp. 671-687
-
-
Hepbasli, A.1
-
9
-
-
33846473699
-
Three-years operation experience of a ground source heat pump system in Northern Greece
-
Michopoulos A., Bozis D., Kikidis P., Papakostas K., and Kyriakis N.A. Three-years operation experience of a ground source heat pump system in Northern Greece. Energy Build 39 (2007) 328-334
-
(2007)
Energy Build
, vol.39
, pp. 328-334
-
-
Michopoulos, A.1
Bozis, D.2
Kikidis, P.3
Papakostas, K.4
Kyriakis, N.A.5
-
11
-
-
35548967503
-
Ground heat exchangers-a review of systems, models and applications
-
Florides G., and Kalogirou S. Ground heat exchangers-a review of systems, models and applications. Renew Energy 32 (2007) 2461-2478
-
(2007)
Renew Energy
, vol.32
, pp. 2461-2478
-
-
Florides, G.1
Kalogirou, S.2
-
12
-
-
36749048841
-
Ground-source heat pumps systems and applications
-
Omer A.M. Ground-source heat pumps systems and applications. Renew Sustain Energy 12 (2008) 344-371
-
(2008)
Renew Sustain Energy
, vol.12
, pp. 344-371
-
-
Omer, A.M.1
-
13
-
-
70349437017
-
Vertical-borehole ground-coupled heat pumps: a review of models and systems
-
[doi:10.1016/j.apenergy.2009.04.038]
-
Yang H., Cui P., and Fang Z. Vertical-borehole ground-coupled heat pumps: a review of models and systems. Appl Energy (2009) [doi:10.1016/j.apenergy.2009.04.038]
-
(2009)
Appl Energy
-
-
Yang, H.1
Cui, P.2
Fang, Z.3
-
14
-
-
77953914315
-
Cooling performance of a vertical ground-coupled heat pump system installed in a school building
-
Hwang Y., Lee J.-K., Jeong Y.-M., Koo K.-M., Lee D.-H., Kim I.-K., et al. Cooling performance of a vertical ground-coupled heat pump system installed in a school building. Renew Energy 5 42 (2008) 1-5
-
(2008)
Renew Energy
, vol.5
, Issue.42
, pp. 1-5
-
-
Hwang, Y.1
Lee, J.-K.2
Jeong, Y.-M.3
Koo, K.-M.4
Lee, D.-H.5
Kim, I.-K.6
-
15
-
-
33748489926
-
Improved underground heat exchanger by using no-dig method for space heating and cooling
-
Hamada Y., Nakamura M., Saitoh H., Kubota H., and Ochifuji K. Improved underground heat exchanger by using no-dig method for space heating and cooling. Renew Energy 32 (2007) 480-495
-
(2007)
Renew Energy
, vol.32
, pp. 480-495
-
-
Hamada, Y.1
Nakamura, M.2
Saitoh, H.3
Kubota, H.4
Ochifuji, K.5
-
16
-
-
14044276173
-
Experimental investigation of the performance of a solar-assisted ground-source heat pump system for greenhouse heating
-
Ozgener O., and Hepbasli A. Experimental investigation of the performance of a solar-assisted ground-source heat pump system for greenhouse heating. Int J Energy Res 29 (2005) 217-231
-
(2005)
Int J Energy Res
, vol.29
, pp. 217-231
-
-
Ozgener, O.1
Hepbasli, A.2
-
17
-
-
64449088311
-
Review of development from GSHP to UTES in China and other countries
-
Gao Q., Li M., Yu M., Spitler J.D., and Yan Y.Y. Review of development from GSHP to UTES in China and other countries. Renew Sustain Energy 13 (2009) 1383-1394
-
(2009)
Renew Sustain Energy
, vol.13
, pp. 1383-1394
-
-
Gao, Q.1
Li, M.2
Yu, M.3
Spitler, J.D.4
Yan, Y.Y.5
-
18
-
-
67649083977
-
Experimental study of heat transfer of buried finned pipe for ground source heat pump applications
-
Koyun A., Demir H., and Torun Z. Experimental study of heat transfer of buried finned pipe for ground source heat pump applications. Int Commun Heat Mass Transfer 36 (2009) 739-743
-
(2009)
Int Commun Heat Mass Transfer
, vol.36
, pp. 739-743
-
-
Koyun, A.1
Demir, H.2
Torun, Z.3
-
19
-
-
0036870964
-
A finite line-source model for boreholes in geothermal heat exchangers
-
Zeng H.Y., Diao N.R., and Fang Z.H. A finite line-source model for boreholes in geothermal heat exchangers. Heat Transfer - Asian Res 31 7 (2002) 558-567
-
(2002)
Heat Transfer - Asian Res
, vol.31
, Issue.7
, pp. 558-567
-
-
Zeng, H.Y.1
Diao, N.R.2
Fang, Z.H.3
-
20
-
-
0042438519
-
A mathematical model of axial fluid temperature for U-tube geothermal heat exchangers
-
[in Chinese]
-
Zeng H., and Fang Z. A mathematical model of axial fluid temperature for U-tube geothermal heat exchangers. J Shandong Inst Architect Eng 17 1 (2002) 7-11 [in Chinese]
-
(2002)
J Shandong Inst Architect Eng
, vol.17
, Issue.1
, pp. 7-11
-
-
Zeng, H.1
Fang, Z.2
-
21
-
-
77953916438
-
A quasi three dimensional heat transfer model for vertical U-tube geothermal heat exchangers
-
[in Chinese]
-
Diao N., Zeng H., and Fang Z. A quasi three dimensional heat transfer model for vertical U-tube geothermal heat exchangers. J Eng Therm Energy Power 18 4 (2003) 387-390 [in Chinese]
-
(2003)
J Eng Therm Energy Power
, vol.18
, Issue.4
, pp. 387-390
-
-
Diao, N.1
Zeng, H.2
Fang, Z.3
|