메뉴 건너뛰기




Volumn 36, Issue 5, 2010, Pages 1083-1089

Relationship between VHF signals and discharge magnitude of partial discharge from needle plate electrode

Author keywords

Apparent discharge magnitude; Cumulative energy; Current pulse measurement; Needle plate electrodes; Peak to peak voltage; Very high frequency(VHF)

Indexed keywords

APPARENT DISCHARGE MAGNITUDE; CUMULATIVE ENERGY; PEAK-TO-PEAK VOLTAGES; PLATE ELECTRODES; VERY HIGH FREQUENCY;

EID: 77953821139     PISSN: 10036520     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (17)

References (16)
  • 1
    • 15744373122 scopus 로고    scopus 로고
    • The actuality and perspective of partial discharge detection techniques
    • GUO Jun, WU Guang-ning, ZHANG Xue-qin, et al. The actuality and perspective of partial discharge detection techniques[J]. Transactions of China Electrotechnical Society, 2005, 20(2): 30-35.
    • (2005) Transactions of China Electrotechnical Society , vol.20 , Issue.2 , pp. 30-35
    • Guo, J.1    Wu, G.-N.2    Zhang, X.-Q.3
  • 2
    • 77953836975 scopus 로고    scopus 로고
    • Application of ultra-high-frequency partial discharge detection in transformers
    • OUYANG Xu-dong, YUAN Peng, LIN Chun-yao, et al. Application of ultra-high-frequency partial discharge detection in transformers[J]. Guangdong Electric Power, 2004, 17(4): 34-36.
    • (2004) Guangdong Electric Power , vol.17 , Issue.4 , pp. 34-36
    • Ouyang, X.-D.1    Yuan, P.2    Lin, C.-Y.3
  • 3
    • 67649145598 scopus 로고    scopus 로고
    • High-voltage teat techniques: Partial discharge measurements
    • IEC 60270
    • IEC 60270. High-voltage teat techniques: partial discharge measurements[S], 2003.
    • (2003)
  • 4
    • 77953852521 scopus 로고    scopus 로고
    • Pulse quantitative determination in partial discharge detection using wide bandwidth pulse current method
    • RUAN Ling, GAO Sheng-you, ZHENG Zhong, et al. Pulse quantitative determination in partial discharge detection using wide bandwidth pulse current method[J]. High Voltage Apparatus, 2009, 45(5): 80-83.
    • (2009) High Voltage Apparatus , vol.45 , Issue.5 , pp. 80-83
    • Ruan, L.1    Gao, S.-Y.2    Zheng, Z.3
  • 5
    • 51149106993 scopus 로고    scopus 로고
    • Comparative research on current pulse method and UHF measurements of partial discharge in mineral oil
    • ZHAO Xiao-hui, YANG Jing-gang, LU Xiu-li, et al. Comparative research on current pulse method and UHF measurements of partial discharge in mineral oil[J]. High Voltage Engineering, 2008, 34(7): 1401-1404.
    • (2008) High Voltage Engineering , vol.34 , Issue.7 , pp. 1401-1404
    • Zhao, X.-H.1    Yang, J.-G.2    Lu, X.-L.3
  • 6
    • 23944456100 scopus 로고    scopus 로고
    • A unique sensitivity verification combined with real-time partial-discharge identification method
    • Toshihiro Hoshino, Shiro Maruyama, Kenichi Nojima, et al. A unique sensitivity verification combined with real-time partial-discharge identification method[J]. IEEE Transactions on Power Delivery, 2005, 20(3): 1890-1896.
    • (2005) IEEE Transactions on Power Delivery , vol.20 , Issue.3 , pp. 1890-1896
    • Hoshino, T.1    Maruyama, S.2    Nojima, K.3
  • 7
    • 77953833749 scopus 로고    scopus 로고
    • Chinese source
    • 2004, 41(11): 29-32.
    • (2004) , vol.41 , Issue.11 , pp. 29-32
  • 8
    • 67649239867 scopus 로고    scopus 로고
    • Relationship between UHF signal energy and charge quantity of partial discharge in transformer oil
    • TANG Ju, ZHOU Jia-bin, HU Zhong, et al. Relationship between UHF signal energy and charge quantity of partial discharge in transformer oil[J]. High Voltage Engineering, 2009, 35(5): 1009-1013.
    • (2009) High Voltage Engineering , vol.35 , Issue.5 , pp. 1009-1013
    • Tang, J.1    Zhou, J.-B.2    Hu, Z.3
  • 9
    • 77953829641 scopus 로고    scopus 로고
    • Chinese source
    • 2008(2): 99-100.
    • (2008) , Issue.2 , pp. 99-100
  • 10
    • 77953862703 scopus 로고    scopus 로고
    • Chinese source
    • 2000.
    • (2000)
  • 11
    • 77953814625 scopus 로고
    • Chinese source
    • 1983.
    • (1983)
  • 12
    • 70349190135 scopus 로고    scopus 로고
    • Calculation of electromagnetic radiation of VSC-HVDC converter stations
    • YU Shi-feng, RUAN Jiang-jun, LIU Bing, et al. Calculation of electromagnetic radiation of VSC-HVDC converter stations[J]. High Voltage Engineering, 2009, 35(8): 1980-1985.
    • (2009) High Voltage Engineering , vol.35 , Issue.8 , pp. 1980-1985
    • Yu, S.-F.1    Ruan, J.-J.2    Liu, B.3
  • 13
    • 77953853268 scopus 로고
    • Chinese source
    • 1994.
    • (1994)
  • 14
    • 77953863289 scopus 로고    scopus 로고
    • Chinese source
    • 1997.
    • (1997)
  • 15
    • 77953868354 scopus 로고    scopus 로고
    • Equivalent model of electromagnetic wave radiated from corna discharge between needle-plate electrodes in loop circuit
    • CHEN Shi-xiu, SHEN Yuan-mao, WU Yuan-li, et al. Equivalent model of electromagnetic wave radiated from corna discharge between needle-plate electrodes in loop circuit[J]. High Voltage Engineering, 2002, 28(s): 9-11.
    • (2002) High Voltage Engineering , vol.28 , Issue.SUPPL. , pp. 9-11
    • Chen, S.-X.1    Shen, Y.-M.2    Wu, Y.-L.3
  • 16
    • 77953856609 scopus 로고    scopus 로고
    • Chinese source
    • 2009, 40(5): 600-604.
    • (2009) , vol.40 , Issue.5 , pp. 600-604


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.