메뉴 건너뛰기




Volumn 397, Issue 5, 2010, Pages 1873-1881

Surface plasmon resonance aided electrochemical immunosensor for CK-MB determination in undiluted serum samples

Author keywords

Creatine kinase MB; Electrochemistry; Immunosensor; Serum; SPR

Indexed keywords

ALKALINE PHOSPHATASE; ANTIBODY BINDING; ANTIBODY IMMOBILIZATION; ASCORBIC ACIDS; CALIBRATION CURVES; COUNTER ELECTRODES; CREATINE KINASE; CREATINE KINASE MB; DETECTION LIMITS; ELECTROCHEMICAL DETECTION; ELECTROCHEMICAL IMMUNOASSAYS; ELECTROCHEMICAL IMMUNOSENSORS; GLASS CHIPS; MEAN STANDARD DEVIATION; MEASURED POINTS; NONSPECIFIC ADSORPTION; QUANTITATIVE ASSESSMENTS; REAL TIME MONITORING; REFERENCE ELECTRODES; SANDWICH IMMUNOASSAY; SENSOR SURFACES; SERUM PROTEINS; SERUM SAMPLES; SPR METHOD; SPR SIGNALS;

EID: 77953812156     PISSN: 16182642     EISSN: 16182650     Source Type: Journal    
DOI: 10.1007/s00216-010-3736-2     Document Type: Article
Times cited : (23)

References (40)
  • 1
    • 0036221549 scopus 로고    scopus 로고
    • Cardiac markers of acute coronary syndromes: Is there a case for point-of-care testing?
    • DOI 10.1016/S0009-9120(02)00277-1, PII S0009912002002771
    • HME Azzazy RH Christenson 2002 Clin Biochem 35 13 27 10.1016/S0009- 9120(02)00277-1 1:CAS:528:DC%2BD38XjsFaisrg%3D (Pubitemid 34286575)
    • (2002) Clinical Biochemistry , vol.35 , Issue.1 , pp. 13-27
    • Azzazy, H.M.E.1    Christenson, R.H.2
  • 3
    • 0035885030 scopus 로고    scopus 로고
    • Recent approaches in standardization of cardiac markers
    • DOI 10.1016/S0009-8981(01)00553-8, PII S0009898101005538
    • M Panteghini 2001 Clin Chim Acta 311 19 25 10.1016/S0009-8981(01)00553-8 1:CAS:528:DC%2BD3MXms12lsr4%3D (Pubitemid 32835204)
    • (2001) Clinica Chimica Acta , vol.311 , Issue.1 , pp. 19-25
    • Panteghini, M.1
  • 4
    • 60749093017 scopus 로고    scopus 로고
    • 10.1016/j.cca.2008.12.037 1:CAS:528:DC%2BD1MXisFahur0%3D
    • M Panteghini 2009 Clin Chim Acta 402 88 93 10.1016/j.cca.2008.12.037 1:CAS:528:DC%2BD1MXisFahur0%3D
    • (2009) Clin Chim Acta , vol.402 , pp. 88-93
    • Panteghini, M.1
  • 7
    • 0035884868 scopus 로고    scopus 로고
    • Point-of-care testing: A cardiologist's view
    • DOI 10.1016/S0009-8981(01)00560-5, PII S0009898101005605
    • P Stubbs PO Collinson 2001 Clin Chim Acta 311 57 61 10.1016/S0009- 8981(01)00560-5 1:CAS:528:DC%2BD3MXms12ls7o%3D (Pubitemid 32835211)
    • (2001) Clinica Chimica Acta , vol.311 , Issue.1 , pp. 57-61
    • Stubbs, P.1    Collinson, P.O.2
  • 9
    • 0035884884 scopus 로고    scopus 로고
    • Point-of-care testing of cardiac markers: Results from an experience in an Emergency Department
    • DOI 10.1016/S0009-8981(01)00562-9, PII S0009898101005629
    • S Altinier M Zaninotto M Mion P Carraro S Rocco F Tosato M Plebani 2001 Clin Chim Acta 311 67 72 10.1016/S0009-8981(01)00562-9 1:CAS:528: DC%2BD3MXms12ls7Y%3D (Pubitemid 32835213)
    • (2001) Clinica Chimica Acta , vol.311 , Issue.1 , pp. 67-72
    • Altinier, S.1    Zaninotto, M.2    Mion, M.3    Carraro, P.4    Rocco, S.5    Tosato, F.6    Plebani, M.7
  • 10
    • 67349154091 scopus 로고    scopus 로고
    • 10.1016/j.cca.2009.03.014 1:CAS:528:DC%2BD1MXmtlOitrg%3D
    • M Plebani 2009 Clin Chim Acta 404 59 64 10.1016/j.cca.2009.03.014 1:CAS:528:DC%2BD1MXmtlOitrg%3D
    • (2009) Clin Chim Acta , vol.404 , pp. 59-64
    • Plebani, M.1
  • 15
    • 0028946444 scopus 로고
    • 10.1016/0003-2670(94)00641-X
    • T Kaláb P Skládal 1995 Anal Chim Acta 304 361 368 10.1016/0003-2670(94)00641-X
    • (1995) Anal Chim Acta , vol.304 , pp. 361-368
    • Kaláb, T.1    Skládal, P.2
  • 16
    • 0030635916 scopus 로고    scopus 로고
    • Scheller FW, Schubert F, Fedrowitz J (eds) Birkhauser, Basel
    • Spener F, Meusel M, Siegmann-Toss C (1997) In: Scheller FW, Schubert F, Fedrowitz J (eds) Frontiers in biosensorics, vol II. Birkhauser, Basel, pp 27-44
    • (1997) Frontiers in Biosensorics , vol.2 , pp. 27-44
    • Spener, F.1    Meusel, M.2    Siegmann-Toss, C.3
  • 17
    • 40449111291 scopus 로고    scopus 로고
    • Surface plasmon resonance sensors for detection of chemical and biological species
    • DOI 10.1021/cr068107d
    • J Homola 2008 Chem Rev 108 462 493 10.1021/cr068107d 1:CAS:528: DC%2BD1cXhtFCiu7Y%3D (Pubitemid 351350388)
    • (2008) Chemical Reviews , vol.108 , Issue.2 , pp. 462-493
    • Homola, J.1
  • 18
    • 33846293986 scopus 로고    scopus 로고
    • Recent advancements in surface plasmon resonance immunosensors for detection of small molecules of biomedical, food and environmental interest
    • DOI 10.1016/j.snb.2006.09.014, PII S0925400506006368
    • DR Shankaran KV Gobi N Miura 2007 Sens Actuators B 121 158 177 10.1016/j.snb.2006.09.014 (Pubitemid 46123891)
    • (2007) Sensors and Actuators, B: Chemical , vol.121 , Issue.1 , pp. 158-177
    • Shankaran, D.R.1    Gobi, K.V.2    Miura, N.3
  • 19
    • 33846344312 scopus 로고    scopus 로고
    • Self-assembled PEG monolayer based SPR immunosensor for label-free detection of insulin
    • DOI 10.1016/j.bios.2006.06.012, PII S0956566306002909
    • KV Gobi H Iwasaka N Miura 2007 Biosens Bioelectron 22 1382 1389 10.1016/j.bios.2006.06.012 1:CAS:528:DC%2BD2sXpvVOltg%3D%3D (Pubitemid 46135994)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.7 , pp. 1382-1389
    • Gobi, K.V.1    Iwasaka, H.2    Miura, N.3
  • 21
    • 33746801083 scopus 로고    scopus 로고
    • On-chip enzyme immunoassay of a cardiac marker using a microfluidic device combined with a portable surface plasmon resonance system
    • DOI 10.1021/ac060480y
    • R Kurita Y Yokota Y Sato F Mizutani O Niwa 2006 Anal Chem 78 5525 5531 10.1021/ac060480y 1:CAS:528:DC%2BD28XmtF2rtb4%3D (Pubitemid 44182373)
    • (2006) Analytical Chemistry , vol.78 , Issue.15 , pp. 5525-5531
    • Kurita, R.1    Yokota, Y.2    Sato, Y.3    Mizutani, F.4    Niwa, O.5
  • 22
    • 17444391646 scopus 로고    scopus 로고
    • Colloidal Au-enhanced surface plasmon resonance immunosensing
    • DOI 10.1021/ac9809940
    • LA Lyon MD Musick MJ Natan 1998 Anal Chem 70 5177 5183 10.1021/ac9809940 1:CAS:528:DyaK1cXntFegtrk%3D (Pubitemid 29011056)
    • (1998) Analytical Chemistry , vol.70 , Issue.24 , pp. 5177-5183
    • Andrew Lyon, L.1    Musick, M.D.2    Natan, M.J.3
  • 23
    • 38749131907 scopus 로고    scopus 로고
    • 10.1016/j.bios.2007.10.026 1:CAS:528:DC%2BD1cXhsFyms7o%3D
    • H Dong X Cao CM Li W Hu 2008 Biosens Bioelectron 23 1055 1062 10.1016/j.bios.2007.10.026 1:CAS:528:DC%2BD1cXhsFyms7o%3D
    • (2008) Biosens Bioelectron , vol.23 , pp. 1055-1062
    • Dong, H.1    Cao, X.2    Li, C.M.3    Hu, W.4
  • 24
    • 0035298832 scopus 로고    scopus 로고
    • Detection of electrochemical enzymatic reactions by surface plasmon resonance measurement
    • DOI 10.1021/ac0012851
    • Y Iwasaki T Horiuchi O Niwa 2001 Anal Chem 73 1595 1598 10.1021/ac0012851 1:CAS:528:DC%2BD3MXhsFKisL8%3D (Pubitemid 32896219)
    • (2001) Analytical Chemistry , vol.73 , Issue.7 , pp. 1595-1598
    • Iwasaki, Y.1    Horiuchi, T.2    Niwa, O.3
  • 28
    • 34250716057 scopus 로고    scopus 로고
    • 10.1039/b611346j 1:CAS:528:DC%2BD28XhtVOltr%2FP
    • M Rooth AM Shaw 2006 Phys Chem Chem Phys 8 4741 4743 10.1039/b611346j 1:CAS:528:DC%2BD28XhtVOltr%2FP
    • (2006) Phys Chem Chem Phys , vol.8 , pp. 4741-4743
    • Rooth, M.1    Shaw, A.M.2
  • 29
    • 0022512416 scopus 로고
    • 10.1016/0003-2697(86)90176-4 1:CAS:528:DyaL28XkvFeku78%3D
    • JV Staros RW Wright DM Swingle 1986 Anal Biochem 156 220 222 10.1016/0003-2697(86)90176-4 1:CAS:528:DyaL28XkvFeku78%3D
    • (1986) Anal Biochem , vol.156 , pp. 220-222
    • Staros, J.V.1    Wright, R.W.2    Swingle, D.M.3
  • 32
    • 69749109854 scopus 로고    scopus 로고
    • 10.1021/ac901068x 1:CAS:528:DC%2BD1MXosFCmurs%3D
    • LA Tessler JG Reifenberger RD Mitra 2009 Anal Chem 81 7141 7148 10.1021/ac901068x 1:CAS:528:DC%2BD1MXosFCmurs%3D
    • (2009) Anal Chem , vol.81 , pp. 7141-7148
    • Tessler, L.A.1    Reifenberger, J.G.2    Mitra, R.D.3
  • 36
  • 37
    • 36049032566 scopus 로고    scopus 로고
    • Enzymatically biocatalytic precipitates amplified antibody-antigen interaction for super low level immunoassay: An investigation combined surface plasmon resonance with electrochemistry
    • DOI 10.1016/j.bios.2007.08.001, PII S0956566307003041
    • H Tang Q Wang Q Xie Y Zhang L Tan S Yao 2007 Biosens Bioelectron 23 668 674 10.1016/j.bios.2007.08.001 1:CAS:528:DC%2BD2sXhtlWksb%2FI (Pubitemid 350101180)
    • (2007) Biosensors and Bioelectronics , vol.23 , Issue.5 , pp. 668-674
    • Tang, H.1    Wang, Q.2    Xie, Q.3    Zhang, Y.4    Tan, L.5    Yao, S.6
  • 38
    • 33845430092 scopus 로고    scopus 로고
    • An SPR immunosensor for human cardiac troponin T using specific binding avidin to biotin at carboxymethyldextran-modified gold chip
    • DOI 10.1016/j.cca.2006.07.029, PII S0009898106004864
    • RF Dutra LT Kubota 2007 Clin Chim Acta 376 114 120 10.1016/j.cca.2006.07. 029 1:CAS:528:DC%2BD28XhtlaltbnO (Pubitemid 44895542)
    • (2007) Clinica Chimica Acta , vol.376 , Issue.1-2 , pp. 114-120
    • Dutra, R.F.1    Kubota, L.T.2
  • 39
    • 33645235292 scopus 로고    scopus 로고
    • 10.1021/ac051868g 1:CAS:528:DC%2BD28Xlt1Ohsg%3D%3D
    • Y Tang R Mernaugh X Zeng 2006 Anal Chem 78 1841 1848 10.1021/ac051868g 1:CAS:528:DC%2BD28Xlt1Ohsg%3D%3D
    • (2006) Anal Chem , vol.78 , pp. 1841-1848
    • Tang, Y.1    Mernaugh, R.2    Zeng, X.3
  • 40
    • 0036181692 scopus 로고    scopus 로고
    • Amperometric microcells for alkaline phosphatase assay
    • DOI 10.1039/b105308f
    • RE Gyurcsanyi A Bereczki G Nagy MR Neuman E Lindner 2002 Analyst 127 235 240 10.1039/b105308f 1:CAS:528:DC%2BD38XpslOksg%3D%3D (Pubitemid 34151239)
    • (2002) Analyst , vol.127 , Issue.2 , pp. 235-240
    • Gyurcsanyi, R.E.1    Bereczki, A.2    Nagy, G.3    Neuman, M.R.4    Lindner, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.