메뉴 건너뛰기




Volumn 397, Issue 5, 2010, Pages 1767-1772

Characterization of dielectric barrier electrospray ionization for mass spectrometric detection

Author keywords

Dielectric barrier; ESI; MS

Indexed keywords

DIELECTRIC MATERIALS; DRUG PRODUCTS; ELECTRIC DISCHARGES; MASS SPECTROMETERS; MASS SPECTROMETRY;

EID: 77953811546     PISSN: 16182642     EISSN: 16182650     Source Type: Journal    
DOI: 10.1007/s00216-010-3749-x     Document Type: Article
Times cited : (22)

References (13)
  • 2
    • 0035476439 scopus 로고    scopus 로고
    • Evaluations of the stability of sheathless electrospray ionization mass spectrometry emitters using electrochemical techniques
    • DOI 10.1021/ac010300e
    • S Nilsson M Svedberg J Pettersson F Björefors K Markides L Nyholm 2001 Anal Chem 73 4607 4616 10.1021/ac010300e 1:CAS:528:DC%2BD3MXmsFSks7c%3D (Pubitemid 32953184)
    • (2001) Analytical Chemistry , vol.73 , Issue.19 , pp. 4607-4616
    • Nilsson, S.1    Svedberg, M.2    Pettersson, J.3    Bjorefors, F.4    Markides, K.5    Nyholm, L.6
  • 7
    • 0035500076 scopus 로고    scopus 로고
    • Sheathless capillary electrophoresis/electrospray mass spectrometry using a carbon-coated tapered fused-silica capillary with a beveled edge
    • DOI 10.1021/ac010429o
    • YZ Chang YR Chen GR Her 2001 Anal Chem 73 5083 5087 10.1021/ac010429o 1:CAS:528:DC%2BD3MXmvF2it7g%3D (Pubitemid 33032221)
    • (2001) Analytical Chemistry , vol.73 , Issue.21 , pp. 5083-5087
    • Yan Zin Chang1    Yet Ran Chen2    Guor Rong Her3
  • 10
    • 0035863620 scopus 로고    scopus 로고
    • Control of electrochemical reactions at the capillary electrophoresis outlet/electrospray emitter electrode under CE/ESI-MS through the application of redox buffers
    • DOI 10.1021/ac0007940
    • AD Smith M Moini 2001 Anal Chem 73 240 246 10.1021/ac0007940 1:CAS:528:DC%2BD3cXoslemu7k%3D (Pubitemid 32061835)
    • (2001) Analytical Chemistry , vol.73 , Issue.2 , pp. 240-246
    • Smith, A.D.1    Moini, M.2
  • 11
    • 34250185717 scopus 로고    scopus 로고
    • Simplifying CE-MS operation. 2. Interfacing low-flow separation techniques to mass spectrometry using a porous tip
    • DOI 10.1021/ac0704560
    • M Moini 2007 Anal Chem 79 4241 4246 10.1021/ac0704560 1:CAS:528:DC%2BD2sXksVWgtLo%3D (Pubitemid 46903180)
    • (2007) Analytical Chemistry , vol.79 , Issue.11 , pp. 4241-4246
    • Moini, M.1
  • 12
    • 0037695183 scopus 로고    scopus 로고
    • Capillary electrophoresis to mass spectrometry interface using a porous junction
    • DOI 10.1021/ac026380j
    • JT Whitt M Moini 2003 Anal Chem 75 2188 2191 10.1021/ac026380j 1:CAS:528:DC%2BD3sXisFClu7c%3D (Pubitemid 36542363)
    • (2003) Analytical Chemistry , vol.75 , Issue.9 , pp. 2188-2191
    • Whitt, J.T.1    Moini, M.2
  • 13
    • 43049138735 scopus 로고    scopus 로고
    • 10.1007/s00216-008-2027-7 1:CAS:528:DC%2BD1cXlt1Cqsrg%3D
    • M Schilling D Janasek J Franzke 2008 Anal Bioanal Chem 391 555 561 10.1007/s00216-008-2027-7 1:CAS:528:DC%2BD1cXlt1Cqsrg%3D
    • (2008) Anal Bioanal Chem , vol.391 , pp. 555-561
    • Schilling, M.1    Janasek, D.2    Franzke, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.