메뉴 건너뛰기




Volumn 21, Issue 7, 2010, Pages

Determination of micro-litre volumes with high accuracy for flow cytometric blood cell counting

Author keywords

Blood cell concentration; Disposable syringe; Glass syringes; Gravimetrical calibration of syringes; Laser flow cytometer; Volume measurement

Indexed keywords

BLOOD; CALIBRATION; CELL ADHESION; CYTOLOGY; FLOWMETERS; GLASS; POLYPROPYLENES; SYRINGES; TITRATION; UNCERTAINTY ANALYSIS; VOLUME MEASUREMENT;

EID: 77953793597     PISSN: 09570233     EISSN: 13616501     Source Type: Journal    
DOI: 10.1088/0957-0233/21/7/074006     Document Type: Article
Times cited : (15)

References (26)
  • 1
    • 77953760114 scopus 로고    scopus 로고
    • Volumenbestimmung im Mikroliterbereich
    • Bremerhafen: Verlag für neue Wissenschaft GmbH
    • Wolf H 2001 Volumenbestimmung im Mikroliterbereich PTB-Bericht ThEx-16 (Bremerhafen: Verlag für neue Wissenschaft GmbH)
    • (2001) PTB-Bericht ThEx-16
    • Wolf, H.1
  • 7
    • 0029146752 scopus 로고
    • Enumeration of platelets by multiparameter flow cytometry using platelet-specific antibodies and fluorescent reference particles
    • Dickerhoff R and von Ruecker A 1995 Enumeration of platelets by multiparameter flow cytometry using platelet-specific antibodies and fluorescent reference particles Clin. Lab. Haematol. 17 163-72
    • (1995) Clin. Lab. Haematol. , vol.17 , pp. 163-172
    • Dickerhoff, R.1    Von Ruecker, A.2
  • 9
    • 0035290712 scopus 로고    scopus 로고
    • Platelet counting by the RBC/platelet ratio method, a reference method
    • International Council for Standardization in Haematology, Klee G, van Assendelft O W (chair) 2001 Platelet counting by the RBC/platelet ratio method, a reference method Am. J. Clin. Pathol. 115 460-4
    • (2001) Am. J. Clin. Pathol. , vol.115 , pp. 460-464
    • Klee, G.1    Van Assendelft, O.W.2
  • 11
    • 0026720602 scopus 로고
    • An adapter for defined sample volume makes it possible to count absolute particle numbers in flow cytometry
    • Schweppe F, Hausmann M, Hexel K, Barths J and Cremer C 1992 An adapter for defined sample volume makes it possible to count absolute particle numbers in flow cytometry Anal. Cell. Pathol. 4 325-34
    • (1992) Anal. Cell. Pathol. , vol.4 , pp. 325-334
    • Schweppe, F.1    Hausmann, M.2    Hexel, K.3    Barths, J.4    Cremer, C.5
  • 13
    • 0032126440 scopus 로고    scopus 로고
    • Flow cytometric differentiation of erythrocytes and leukocytes in dilute whole blood by light scattering
    • Ost V, Neukammer J and Rinneberg H 1998 Flow cytometric differentiation of erythrocytes and leukocytes in dilute whole blood by light scattering Cytometry 32 191-7
    • (1998) Cytometry , vol.32 , pp. 191-197
    • Ost, V.1    Neukammer, J.2    Rinneberg, H.3
  • 14
  • 15
    • 0035215797 scopus 로고    scopus 로고
    • Recommended table for the density of water between 0 °c and 40 °c based on recent experimental reports
    • Tanaka M, Girard G, Davis R, Peuto A and Bignell N 2001 Recommended table for the density of water between 0 °C and 40 °C based on recent experimental reports Metrologia 38 301-9
    • (2001) Metrologia , vol.38 , pp. 301-309
    • Tanaka, M.1    Girard, G.2    Davis, R.3    Peuto, A.4    Bignell, N.5
  • 16
    • 0026657025 scopus 로고
    • Minimum distinguishable difference in concentration: A clinically oriented translation of assay precision summaries
    • Sadler W A, Murray L M and Turner J G 1992 Minimum distinguishable difference in concentration: a clinically oriented translation of assay precision summaries Clin. Chem. 38 1773-8
    • (1992) Clin. Chem. , vol.38 , pp. 1773-1778
    • Sadler, W.A.1    Murray, L.M.2    Turner, J.G.3
  • 17
    • 77953749226 scopus 로고
    • Bestimmung der Blutkörperchenkonzentration im Blut: Bestimmung der Konzentration der Erythrozyten, Referenzmethode DIN
    • Standardization Committee 'Haematology' of the German Institute for Standardization
    • Standardization Committee 'Haematology' of the German Institute for Standardization 1994 Bestimmung der Blutkörperchenkonzentration im Blut: Bestimmung der Konzentration der Erythrozyten, Referenzmethode DIN 58 932-3
    • (1994) DIN , vol.58 , pp. 932-933
  • 18
    • 77953739704 scopus 로고    scopus 로고
    • Determination of the concentration of blood corpuscles in blood: Part 4. Reference procedure for the determination of the concentration of leucocytes
    • Standardization Committee 'Haematology' of the German Institute for Standardization
    • Standardization Committee 'Haematology' of the German Institute for Standardization 2003 Determination of the concentration of blood corpuscles in blood: part 4. Reference procedure for the determination of the concentration of leucocytes DIN 58 932'4 (in German and English)
    • (2003) DIN , vol.58 , pp. 932-938
  • 19
    • 77953739704 scopus 로고    scopus 로고
    • Concentration of blood corpuscles in blood: Part 5. Reference method for the determination of the concentration of thrombocytes
    • Standardization Committee 'Haematology' of the German Institute for Standardization
    • Standardization Committee 'Haematology' of the German Institute for Standardization 2007 Determination of the concentration of blood corpuscles in blood: part 5. Reference method for the determination of the concentration of thrombocytes DIN 58 932'5 (in German and English)
    • (2007) DIN , vol.58 , pp. 932-935
  • 20
    • 0024386172 scopus 로고
    • Coincidence correction in red blood cell counting
    • Lewis S M, England J M and Kubota F 1989 Coincidence correction in red blood cell counting Phys. Med. Biol. 34 1239'46
    • (1989) Phys. Med. Biol. , vol.34 , pp. 1239-1246
    • Lewis, S.M.1    England, J.M.2    Kubota, F.3
  • 22
    • 77953772277 scopus 로고
    • Korrektion koinzidenzbedingter Za"hlverluste bei Partikelza"hlgera"ten
    • Jakschik J and Schulze K 1990 Korrektion koinzidenzbedingter Za"hlverluste bei Partikelza"hlgera"ten Lab. Med. 13 3'6, 89'96, 175'81
    • (1990) Lab. Med. , vol.13 , pp. 3-6
    • Jakschik, J.1    Schulze, K.2
  • 25
    • 62649119668 scopus 로고    scopus 로고
    • Microfluidic structures for flow cytometric analysis of hydrodynamically focussed blood cells fabricated by ultraprecision micromachining
    • Kummrow A, Theisen J, Frankowski M, Tuchscheerer A, Yildirim H, Brattke K, Schmidt M and Neukammer J 2009 Microfluidic structures for flow cytometric analysis of hydrodynamically focussed blood cells fabricated by ultraprecision micromachining Lab. Chip 9 972-81
    • (2009) Lab. Chip , vol.9 , pp. 972-981
    • Kummrow, A.1    Theisen, J.2    Frankowski, M.3    Tuchscheerer, A.4    Yildirim, H.5    Brattke, K.6    Schmidt, M.7    Neukammer, J.8
  • 26
    • 71249124807 scopus 로고    scopus 로고
    • Methods for counting particles in microfluidic applications
    • Zhang H, Chon C H, Pan X and Li D 2009 Methods for counting particles in microfluidic applications Microfluid Nanofluid 7 739-49
    • (2009) Microfluid Nanofluid , vol.7 , pp. 739-749
    • Zhang, H.1    Chon, C.H.2    Pan, X.3    Li, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.