메뉴 건너뛰기




Volumn 57, Issue 3 PART 1, 2010, Pages 1023-1028

Calibration procedure for a continuous miniature crystal element (cMiCE) detector

Author keywords

Calibration; Continuous crystal; High spatial resolution; PET detector

Indexed keywords

CALIBRATION PROCEDURE; CALIBRATION PROCESS; COINCIDENCE COUNTING RATES; CONTINUOUS CRYSTAL; FOUR-POINT; HIGH SPATIAL RESOLUTION; LOOK UP TABLE; LYSO CRYSTALS; MINIATURE CRYSTALS; MULTI-SOURCE DEVICES; MULTIPLE POINTS; PET DETECTOR; PET DETECTORS; PHOTOMULTIPLIER TUBE; SAMPLING INTERVAL; SPATIAL RESOLUTION; SPEED-UP FACTORS; SPEED-UPS; STATISTICS-BASED POSITIONING ALGORITHM;

EID: 77953715471     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2010.2043261     Document Type: Article
Times cited : (23)

References (12)
  • 2
    • 60749098231 scopus 로고    scopus 로고
    • Depth of interaction detection for 'γ-ray imaging
    • C. W. Lerche et al., "Depth of interaction detection for 'γ-ray imaging," Nucl. Instrum. Meth. Phys. Res. A, vol.600, pp. 624-634, 2009.
    • (2009) Nucl. Instrum. Meth. Phys. Res. A , vol.600 , pp. 624-634
    • Lerche, C.W.1
  • 3
    • 33846356293 scopus 로고    scopus 로고
    • Towards a continuous crystal APD-based PET detector design
    • P. Bruyndonckx et al., "Towards a continuous crystal APD-based PET detector design," Nucl. Instrum. Meth. Phys. Res. A, vol.571, pp. 182-186, 2007.
    • (2007) Nucl. Instrum. Meth. Phys. Res. A , vol.571 , pp. 182-186
    • Bruyndonckx, P.1
  • 4
    • 33846397700 scopus 로고    scopus 로고
    • Investigation of an in situ position calibration method for continuous crystal-based PET detectors
    • P. Bruyndonckx et al., "Investigation of an in situ position calibration method for continuous crystal-based PET detectors," Nucl. Instrum. Meth. Phys. Res. A, vol.571, pp. 304-307, 2007.
    • (2007) Nucl. Instrum. Meth. Phys. Res. A , vol.571 , pp. 304-307
    • Bruyndonckx, P.1
  • 5
    • 33846540801 scopus 로고    scopus 로고
    • Scanner calibration of a small animal PET camera based on continuous LSO crystals and flat panel PSPMTs
    • J. M. Benlloch et al., "Scanner calibration of a small animal PET camera based on continuous LSO crystals and flat panel PSPMTs," Nucl. Instrum. Meth. Phys. Res. A, vol.571, pp. 26-29, 2007.
    • (2007) Nucl. Instrum. Meth. Phys. Res. A , vol.571 , pp. 26-29
    • Benlloch, J.M.1
  • 6
    • 0038382221 scopus 로고    scopus 로고
    • Effects of intercrystal crosstalk on multielement LSO/APD PET detectors
    • June
    • P. Vaska, S. P. Stoll, C. L. Woody, D. J. Schlyer, and S. Shokouhi, "Effects of intercrystal crosstalk on multielement LSO/APD PET detectors," IEEE Trans. Nucl. Sci., vol. 50, no. 3, pp. 362-366, June 2003.
    • (2003) IEEE Trans. Nucl. Sci , vol.50 , Issue.3 , pp. 362-366
    • Vaska, P.1    Stoll, S.P.2    Woody, C.L.3    Schlyer, D.J.4    Shokouhi, S.5
  • 8
    • 60449113413 scopus 로고    scopus 로고
    • Calibration method for ML estimation of 3D interaction position in a thick gamma-ray detector
    • Feb.
    • W. C. J. Hunter, H. H. Barrett, and L. R. Furenlid, "Calibration method for ML estimation of 3D interaction position in a thick gamma-ray detector," IEEE Trans. Nucl. Sci., vol. 56, no. 1, pp. 189-196, Feb. 2009.
    • (2009) IEEE Trans. Nucl. Sci , vol.56 , Issue.1 , pp. 189-196
    • Hunter, W.C.J.1    Barrett, H.H.2    Furenlid, L.R.3
  • 9
    • 0037151412 scopus 로고    scopus 로고
    • CMiCE: A high resolution animal PET using continuous LSO with a statistics based positioning scheme
    • Aug.
    • J. Joung, R. S. Miyaoka, and T. K. Lewellen, "CMiCE: A high resolution animal PET using continuous LSO with a statistics based positioning scheme," Nucl. Instrum. Meth. Phys. Res. A, vol. 489, no. 1-3, pp. 584-589, Aug. 2002.
    • (2002) Nucl. Instrum. Meth. Phys. Res. A , vol.489 , Issue.1-3 , pp. 584-589
    • Joung, J.1    Miyaoka, R.S.2    Lewellen, T.K.3
  • 10
    • 33750411760 scopus 로고    scopus 로고
    • Performance comparisons of continuous miniature crystal element (cMiCE) detectors
    • Oct.
    • T. Ling, K. Lee, and R. S. Miyaoka, "Performance comparisons of continuous miniature crystal element (cMiCE) detectors," IEEE Trans. Nucl. Sci., vol. 53, no. 5, pp. 2513-2518, Oct. 2006.
    • (2006) IEEE Trans. Nucl. Sci , vol.53 , Issue.5 , pp. 2513-2518
    • Ling, T.1    Lee, K.2    Miyaoka, R.S.3
  • 11
    • 34147139307 scopus 로고    scopus 로고
    • Depth of interaction decoding for a continuous crystal detector
    • Apr.
    • T. Ling, T. K. Lewellen, and R. S. Miyaoka, "Depth of interaction decoding for a continuous crystal detector," Phys. Med. Biol., vol.52, pp. 2213-2228, Apr. 2007.
    • (2007) Phys. Med. Biol , vol.52 , pp. 2213-2228
    • Ling, T.1    Lewellen, T.K.2    Miyaoka, R.S.3
  • 12
    • 3342997882 scopus 로고    scopus 로고
    • Sudbury neutrino observatory neutral current detector acquisition software overview
    • Jun.
    • M. A. Howe, G. A. Cox, P. J. Harvey, F. McGirt, K. Rielage, J. F. Wilkerson, and J. M. Wouters, "Sudbury neutrino observatory neutral current detector acquisition software overview," IEEE Trans. Nucl. Sci., vol. 51, no. 3, pt. 3, pp. 878-883, Jun. 2004.
    • (2004) IEEE Trans. Nucl. Sci , vol.51 , Issue.3 PART 3 , pp. 878-883
    • Howe, M.A.1    Cox, G.A.2    Harvey, P.J.3    McGirt, F.4    Rielage, K.5    Wilkerson, J.F.6    Wouters, J.M.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.