메뉴 건너뛰기




Volumn 57, Issue 3 PART 1, 2010, Pages 971-975

Depth of interaction with a 3-dimensional checkerboard arrangement LSO-LSO block

Author keywords

Block detector; Depth of interaction; Lutetium oxy orthosilicate (LSO); Positron emission tomography (PET)

Indexed keywords

3-DIMENSIONAL; BLOCK DETECTORS; CO-DOPING; CURRENT DETECTOR; DECAY TIME; DEPTH OF INTERACTIONS; DEPTH-OF-INTERACTION INFORMATIONS; EMISSION SPECTRUMS; FAST TIMING; FIELD OF VIEWS; LIGHT GUIDES; LIGHT OUTPUT; LUTETIUM OXY-ORTHOSILICATE (LSO); LUTETIUM OXYORTHOSILICATE; PARALLAX ERROR; PHOSWICH DETECTOR; PHOTON INTERACTIONS; PULSE SHAPE DISCRIMINATION; SCINTILLATOR MATERIALS; SCINTILLATOR PIXELS; SHORT DECAY TIME; TIME-OF-FLIGHT PET; TIMING RESOLUTIONS;

EID: 77953712489     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2010.2041070     Document Type: Article
Times cited : (2)

References (19)
  • 1
    • 51849109068 scopus 로고    scopus 로고
    • Recent developments in PET detector technology
    • Sep.
    • T. K. Lewellen, "Recent developments in PET detector technology," Phys. Med. Biol, vol.53, pp. R287-R317, Sep. 2008.
    • (2008) Phys. Med. Biol , vol.53
    • Lewellen, T.K.1
  • 2
    • 33745490063 scopus 로고    scopus 로고
    • Positron emission tomography
    • G. Muehllehner and J. S. Karp, "Positron emission tomography," Phys. Med. Biol, vol. 51, no. 13, p. R117, 2006.
    • (2006) Phys. Med. Biol , vol.51 , Issue.13
    • Muehllehner, G.1    Karp, J.S.2
  • 3
    • 33746335330 scopus 로고    scopus 로고
    • Timing performance of Hi-Rez detector for time-of-flight (TOF) PET
    • M. Aykac, F. Bauer, C. W. Williams, M. Loope, and M. Schmand, "Timing performance of Hi-Rez detector for time-of-flight (TOF) PET," IEEE Trans. Nucl. Sci., vol.53, pp. 1084-1089, 2006.
    • (2006) IEEE Trans. Nucl. Sci , vol.53 , pp. 1084-1089
    • Aykac, M.1    Bauer, F.2    Williams, C.W.3    Loope, M.4    Schmand, M.5
  • 5
    • 0142126690 scopus 로고    scopus 로고
    • Time of flight in PET revisited
    • W. W. Moses, "Time of flight in PET revisited," IEEE Trans. Nucl. Sci., vol.50, pp. 1325-1330, 2003.
    • (2003) IEEE Trans. Nucl. Sci , vol.50 , pp. 1325-1330
    • Moses, W.W.1
  • 6
    • 34247230296 scopus 로고    scopus 로고
    • Performance of philips gemini TF PET/CT scanner with special consideration for its time-of-Flight imaging capabilities
    • Mar.
    • S. Surti, A. Kuhn, M. E. Werner, A. E. Perkins, J. Kolthammer, and J. S. Karp, "Performance of philips gemini TF PET/CT scanner with special. consideration for its time-of-Flight imaging capabilities," J. Nucl. Med., vol. 48, no. 3, pp. 471-480, Mar. 2007.
    • (2007) J. Nucl. Med , vol.48 , Issue.3 , pp. 471-480
    • Surti, S.1    Kuhn, A.2    Werner, M.E.3    Perkins, A.E.4    Kolthammer, J.5    Karp, J.S.6
  • 10
    • 0032136644 scopus 로고    scopus 로고
    • Parallax correction in PET using depth of interaction information
    • L. R. MacDonald and M. Dahlbom, "Parallax correction in PET using depth of interaction information," IEEE Trans. Nucl. Sci., vol.45, pp. 2232-2237, 1998. (Pubitemid 128739273)
    • (1998) IEEE Transactions on Nuclear Science , vol.45 , Issue.4 PART 2 , pp. 2232-2237
    • MacDonald, L.R.1    Dahlbom, M.2
  • 11
    • 0033321161 scopus 로고    scopus 로고
    • Advantages using pulse shape discrimination to assign the depth of interaction information (DOI) from a multi layer phoswich detector
    • M. Schmand, L. Eriksson, M. E. Casey, K. Wienhard, G. Flugge, and R. Nutt, "Advantages using pulse shape discrimination to assign the depth of interaction information (DOI) from a multi layer phoswich detector," IEEE Trans. Nucl. Sci., vol.46, pp. 985-990, 1999.
    • (1999) IEEE Trans. Nucl. Sci , vol.46 , pp. 985-990
    • Schmand, M.1    Eriksson, L.2    Casey, M.E.3    Wienhard, K.4    Flugge, G.5    Nutt, R.6
  • 13
    • 0032100082 scopus 로고    scopus 로고
    • A GSO depth of interaction detector for PET
    • S. Yamamoto and H. Ishibashi, "A GSO depth of interaction detector for PET," IEEE Trans. Nucl. Sci., vol.45, pp. 1078-1082, 1998.
    • (1998) IEEE Trans. Nucl. Sci , vol.45 , pp. 1078-1082
    • Yamamoto, S.1    Ishibashi, H.2
  • 16
    • 77953691522 scopus 로고    scopus 로고
    • High-Resolution Depth-of-Interaction PET Detector United States 7, 601, 963., Knoxville, TN: Siemens Medical. Solutions USA, Inc., USPTO
    • M. Aykac and R. Grazioso, High-Resolution Depth-of-Interaction PET Detector United States 7, 601, 963. Knoxville, TN: Siemens Medical. Solutions USA, Inc., USPTO, 2007.
    • (2007)
    • Aykac, M.1    Grazioso, R.2
  • 18
    • 77953720716 scopus 로고    scopus 로고
    • 3M, VM2000 Radiant Mirror Product Information
    • 3M, VM2000 Radiant Mirror Product Information.
  • 19
    • 34250026577 scopus 로고
    • Pulse shape discrimination with a comparator circuit
    • L. J. Heistek and L. van der Zwan, "Pulse shape discrimination with a comparator circuit," Nucl. Instrum. Methods, vol. 80, no. 2, pp. 213-216, 1970.
    • (1970) Nucl. Instrum. Methods , vol.80 , Issue.2 , pp. 213-216
    • Heistek, L.J.1    Van Der Zwan, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.