메뉴 건너뛰기




Volumn 8, Issue C, 2006, Pages 599-613

Factors influencing the determination of ultra low levels of Pu-isotopes by sector field ICP-MS

Author keywords

Abundance sensitivity; ICP MS; Mass spectrometry; Pu; Uranium hydride

Indexed keywords


EID: 77953711990     PISSN: 15694860     EISSN: None     Source Type: Book Series    
DOI: 10.1016/S1569-4860(05)08048-4     Document Type: Review
Times cited : (1)

References (24)
  • 1
    • 4344582026 scopus 로고    scopus 로고
    • Evaluation of a single collector, double focusing sector field inductively coupled plasma mass spectrometer for the determination of U and Pu concentrations and isotopic compositions at trace level
    • Baglan N., Hemet P., Pointurier F., and Chiappini R. Evaluation of a single collector, double focusing sector field inductively coupled plasma mass spectrometer for the determination of U and Pu concentrations and isotopic compositions at trace level. Journal of Radioanalytical and Nuclear Chemistry 261 3 (2004) 609-617
    • (2004) Journal of Radioanalytical and Nuclear Chemistry , vol.261 , Issue.3 , pp. 609-617
    • Baglan, N.1    Hemet, P.2    Pointurier, F.3    Chiappini, R.4
  • 2
    • 0001325143 scopus 로고    scopus 로고
    • Precise isotope ratio measurements of uranium, thorium and plutonium by quadrupole-based inductively coupled plasma mass spectrometry
    • Becker J.S., and Dietze H.-J. Precise isotope ratio measurements of uranium, thorium and plutonium by quadrupole-based inductively coupled plasma mass spectrometry. Fresenius Journal of Analytical Chemistry 364 (1999) 482-488
    • (1999) Fresenius Journal of Analytical Chemistry , vol.364 , pp. 482-488
    • Becker, J.S.1    Dietze, H.-J.2
  • 7
    • 0041415763 scopus 로고
    • Mass spectrometry and applications to uranium-series disequilibrium
    • Applications to Earth, Marine, and Environmental Sciences. Ivanovich M., and Harmon R.S. (Eds), Clarendon Press, Oxford (Chapter 6)
    • Chen J.H., Edwards R.L., and Wasserburg G.J. Mass spectrometry and applications to uranium-series disequilibrium. In: Ivanovich M., and Harmon R.S. (Eds). Applications to Earth, Marine, and Environmental Sciences. Uranium-Series Disequilibrium (1992), Clarendon Press, Oxford (Chapter 6)
    • (1992) Uranium-Series Disequilibrium
    • Chen, J.H.1    Edwards, R.L.2    Wasserburg, G.J.3
  • 9
    • 0141905802 scopus 로고    scopus 로고
    • Further investigations on optimized tail correction and high-precision measurement of uranium isotopic ratios using multi-collector ICP-MS
    • Deschamps P., Doucelance R., Ghaleb B., and Michelot J.-L. Further investigations on optimized tail correction and high-precision measurement of uranium isotopic ratios using multi-collector ICP-MS. Chemical Geology 201 (2003) 141-160
    • (2003) Chemical Geology , vol.201 , pp. 141-160
    • Deschamps, P.1    Doucelance, R.2    Ghaleb, B.3    Michelot, J.-L.4
  • 10
    • 0030194956 scopus 로고    scopus 로고
    • Determination of trace-amounts plutonium using fission track analysis
    • Johansson L., and Holm E. Determination of trace-amounts plutonium using fission track analysis. Nuclear Instruments and Methods A 376 (1996) 242-247
    • (1996) Nuclear Instruments and Methods A , vol.376 , pp. 242-247
    • Johansson, L.1    Holm, E.2
  • 12
    • 0033875396 scopus 로고    scopus 로고
    • Rapid determination of Pu isotopes and atom ratios in small amounts of environmental samples by an on-line sample pre-treatment system and isotope dilution high resolution inductively coupled plasma mass spectrometry
    • Kim C.-S., Kim C.-K., Lee J.-I., and Lee K.-J. Rapid determination of Pu isotopes and atom ratios in small amounts of environmental samples by an on-line sample pre-treatment system and isotope dilution high resolution inductively coupled plasma mass spectrometry. Journal of Analytical Atomic Spectrometry 15 (2000) 247-255
    • (2000) Journal of Analytical Atomic Spectrometry , vol.15 , pp. 247-255
    • Kim, C.-S.1    Kim, C.-K.2    Lee, J.-I.3    Lee, K.-J.4
  • 13
    • 0348167503 scopus 로고    scopus 로고
    • Separation of plutonium from soil and sediment prior to determination by inductively coupled plasma mass spectrometry
    • Nygren U., Rodushkin I., Nilsson C., and Baxter D. Separation of plutonium from soil and sediment prior to determination by inductively coupled plasma mass spectrometry. Journal of Analytical Atomic Spectrometry 18 (2003) 1426-1434
    • (2003) Journal of Analytical Atomic Spectrometry , vol.18 , pp. 1426-1434
    • Nygren, U.1    Rodushkin, I.2    Nilsson, C.3    Baxter, D.4
  • 15
    • 1342329462 scopus 로고    scopus 로고
    • Ultra low-level measurements of actinides by sector field ICP-MS
    • Pointurier F., Baglan N., and Hemet P. Ultra low-level measurements of actinides by sector field ICP-MS. Applied Radiation and Isotopes 60 (2004) 561-566
    • (2004) Applied Radiation and Isotopes , vol.60 , pp. 561-566
    • Pointurier, F.1    Baglan, N.2    Hemet, P.3
  • 16
    • 0034999290 scopus 로고    scopus 로고
    • 230Th in volcanic rocks: A comparison of thermal ionization mass spectrometry and other methodologies
    • 230Th in volcanic rocks: A comparison of thermal ionization mass spectrometry and other methodologies. Chemical Geology 175 3-4 (2001) 723-750
    • (2001) Chemical Geology , vol.175 , Issue.3-4 , pp. 723-750
    • Rubin, K.H.1
  • 17
    • 0032206073 scopus 로고    scopus 로고
    • The effect of nitric acid concentration and nebulizer gas flow rates on aerosol properties and transport rates in inductively coupled plasma sample introduction
    • Stewart I.I., and Olesik J.W. The effect of nitric acid concentration and nebulizer gas flow rates on aerosol properties and transport rates in inductively coupled plasma sample introduction. Journal of Analytical Atomic Spectrometry 13 (1998) 1249-1256
    • (1998) Journal of Analytical Atomic Spectrometry , vol.13 , pp. 1249-1256
    • Stewart, I.I.1    Olesik, J.W.2
  • 18
    • 0032324634 scopus 로고    scopus 로고
    • High resolution inductively coupled plasma mass spectrometry for the trace determination of plutonium isotopes and isotope ratios in environmental samples
    • Sturup S., Dahlgaard H., and Nielsen S.C. High resolution inductively coupled plasma mass spectrometry for the trace determination of plutonium isotopes and isotope ratios in environmental samples. Journal of Analytical Atomic Spectrometry 13 (1998) 1321-1326
    • (1998) Journal of Analytical Atomic Spectrometry , vol.13 , pp. 1321-1326
    • Sturup, S.1    Dahlgaard, H.2    Nielsen, S.C.3
  • 20
    • 0034740668 scopus 로고    scopus 로고
    • Inappropriate tail corrections can cause large inaccuracy in isotope ratio determination by MC-ICP-MS
    • Thirlwall M.F. Inappropriate tail corrections can cause large inaccuracy in isotope ratio determination by MC-ICP-MS. Journal of Analytical Atomic Spectrometry 16 (2001) 1121-1125
    • (2001) Journal of Analytical Atomic Spectrometry , vol.16 , pp. 1121-1125
    • Thirlwall, M.F.1
  • 21
    • 0041848204 scopus 로고    scopus 로고
    • Rapid analysis for plutonium-239 in urine by magnetic sector inductively coupled plasma-mass spectrometry using Aridus desolvation introduction system
    • Ting B.G., Pappas R.S., and Paschal D.C. Rapid analysis for plutonium-239 in urine by magnetic sector inductively coupled plasma-mass spectrometry using Aridus desolvation introduction system. Journal of Analytical Atomic Spectrometry 18 (2003) 795-797
    • (2003) Journal of Analytical Atomic Spectrometry , vol.18 , pp. 795-797
    • Ting, B.G.1    Pappas, R.S.2    Paschal, D.C.3
  • 23
    • 0035526846 scopus 로고    scopus 로고
    • ICP-sector field mass spectrometry analysis of plutonium isotopes: Recognizing and resolving potential interferences
    • Wyse E.J., Lee S.H., La Rosa J., Povinec P., and de Mora S.J. ICP-sector field mass spectrometry analysis of plutonium isotopes: Recognizing and resolving potential interferences. Journal of Analytical Atomic Spectrometry 16 (2001) 1107-1111
    • (2001) Journal of Analytical Atomic Spectrometry , vol.16 , pp. 1107-1111
    • Wyse, E.J.1    Lee, S.H.2    La Rosa, J.3    Povinec, P.4    de Mora, S.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.