메뉴 건너뛰기




Volumn 34, Issue 6, 2010, Pages 463-475

Exergetic performance assessment of a variable-speed R404a refrigeration system

Author keywords

Exergy; Irreversibility; R404a; Refrigeration; Variable speed

Indexed keywords

EXERGETIC EFFICIENCY; EXERGETIC PERFORMANCE; EXERGY ANALYSIS; EXPANSION VALVES; FREQUENCY INVERTER; IRREVERSIBILITY RATE; LOW-FREQUENCY VALUES; R404A; REFRIGERATION SYSTEM; ROTATIONAL SPEED; SYSTEM COMPONENTS; VARIABLE SPEED;

EID: 77953680392     PISSN: 0363907X     EISSN: 1099114X     Source Type: Journal    
DOI: 10.1002/er.1553     Document Type: Article
Times cited : (12)

References (23)
  • 1
    • 0142126314 scopus 로고    scopus 로고
    • An evaluation of R22 substitutes performances regulating continuously the compressor refrigeration capacity
    • Aprea C, Mastrullo R, Renno C, Vanoli GP. An evaluation of R22 substitutes performances regulating continuously the compressor refrigeration capacity. Applied Thermal Engineering 2004; 24:127-139.
    • (2004) Applied Thermal Engineering , vol.24 , pp. 127-139
    • Aprea, C.1    Mastrullo, R.2    Renno, C.3    Vanoli, G.P.4
  • 4
    • 48249117971 scopus 로고    scopus 로고
    • Performance and exergetic analysis of vapor compression refrigeration system with an internal heat exchanger using a hydrocarbon, isobutane (R600a)
    • Kabul A, Ki{dotless}zi{dotless}lkan Ö, Yakut AK. Performance and exergetic analysis of vapor compression refrigeration system with an internal heat exchanger using a hydrocarbon, isobutane (R600a). International Journal of Energy Research 2008; 32:824-836.
    • (2008) International Journal of Energy Research , vol.32 , pp. 824-836
    • Kabul, A.1    Kizilkan, Ö.2    Yakut, A.K.3
  • 7
    • 0031995195 scopus 로고    scopus 로고
    • Thermal performance of a variable capacity direct expansion solarassisted heat pump
    • Chaturvedi SK, Chen DT, Kheireddine A. Thermal performance of a variable capacity direct expansion solarassisted heat pump. Energy Conversion and Management 1998; 39:181-191.
    • (1998) Energy Conversion and Management , vol.39 , pp. 181-191
    • Chaturvedi, S.K.1    Chen, D.T.2    Kheireddine, A.3
  • 9
    • 2442479639 scopus 로고    scopus 로고
    • An experimental analysis of a thermodynamic model of a vapour compression refrigeration plant on varying the compressor speed
    • Aprea C, Renno C. An experimental analysis of a thermodynamic model of a vapour compression refrigeration plant on varying the compressor speed. International Journal of Energy Research 2004; 28:537-549.
    • (2004) International Journal of Energy Research , vol.28 , pp. 537-549
    • Aprea, C.1    Renno, C.2
  • 10
    • 21644435554 scopus 로고    scopus 로고
    • Energy and exergy analysis of geothermal district heating systems: an application
    • Ozgener L, Hepbasli A, Dincer I. Energy and exergy analysis of geothermal district heating systems: an application. Building and Environment 2005; 40:1309-1322.
    • (2005) Building and Environment , vol.40 , pp. 1309-1322
    • Ozgener, L.1    Hepbasli, A.2    Dincer, I.3
  • 11
    • 0037054468 scopus 로고    scopus 로고
    • Fundamentals of exergy analysis, entropy generation minimization, and the generation of flow architecture
    • Bejan A. Fundamentals of exergy analysis, entropy generation minimization, and the generation of flow architecture. International Journal of Energy Research 2002; 26:545-565.
    • (2002) International Journal of Energy Research , vol.26 , pp. 545-565
    • Bejan, A.1
  • 13
    • 37349106796 scopus 로고    scopus 로고
    • A study on estimating the energetic and exergetic prices of various residential energy sources
    • Hepbasli A. A study on estimating the energetic and exergetic prices of various residential energy sources. Energy and Buildings 2008; 40:308-315.
    • (2008) Energy and Buildings , vol.40 , pp. 308-315
    • Hepbasli, A.1
  • 14
    • 35748986422 scopus 로고    scopus 로고
    • Thermoeconomic analysis of household refrigerators
    • Hepbasli A. Thermoeconomic analysis of household refrigerators. International Journal of Energy Research 2007; 31:947-959.
    • (2007) International Journal of Energy Research , vol.31 , pp. 947-959
    • Hepbasli, A.1
  • 15
    • 0036832059 scopus 로고    scopus 로고
    • Principles of exergy analysis in HVAC and evaluation of evaporative cooling schemes
    • Chengqin R, Nianping L, Guangfa T. Principles of exergy analysis in HVAC and evaluation of evaporative cooling schemes. Building and Environment 2002; 37:1045-1055.
    • (2002) Building and Environment , vol.37 , pp. 1045-1055
    • Chengqin, R.1    Nianping, L.2    Guangfa, T.3
  • 17
    • 1142304577 scopus 로고    scopus 로고
    • Calculation for physical and chemical exergy of flows in systems elaborating mixedphase flows and a case study in an IRSOFC plant
    • Xiang JY, Calí M, Santarelli M. Calculation for physical and chemical exergy of flows in systems elaborating mixedphase flows and a case study in an IRSOFC plant. International Journal of Energy Research 2004; 28:101-115.
    • (2004) International Journal of Energy Research , vol.28 , pp. 101-115
    • Xiang, J.Y.1    Calí, M.2    Santarelli, M.3
  • 18
    • 0344118171 scopus 로고    scopus 로고
    • Energy and exergy analysis of a ground source (geothermal) heat pump system
    • Hepbasli A, Akdemir O. Energy and exergy analysis of a ground source (geothermal) heat pump system. Energy Conversion and Management 2004; 45:737-753.
    • (2004) Energy Conversion and Management , vol.45 , pp. 737-753
    • Hepbasli, A.1    Akdemir, O.2
  • 19
    • 33745835788 scopus 로고    scopus 로고
    • Effect of saturation-temperature on the performance of a vapour-compression refrigerationcycle working on different refrigerants using exergy method, short communication
    • Kopac M, Zemher B. Effect of saturation-temperature on the performance of a vapour-compression refrigerationcycle working on different refrigerants using exergy method, short communication. International Journal of Energy Research 2006; 30:729-740.
    • (2006) International Journal of Energy Research , vol.30 , pp. 729-740
    • Kopac, M.1    Zemher, B.2
  • 20
    • 41749094271 scopus 로고    scopus 로고
    • Exergetic assessment of direct-expansion solar-assisted heat pump systems: review and modeling
    • Kara O, Ulgen K, Hepbasli A. Exergetic assessment of direct-expansion solar-assisted heat pump systems: review and modeling. Renewable and Sustainable Energy Reviews 2008; 12:1383-1401.
    • (2008) Renewable and Sustainable Energy Reviews , vol.12 , pp. 1383-1401
    • Kara, O.1    Ulgen, K.2    Hepbasli, A.3
  • 21
    • 0032416039 scopus 로고    scopus 로고
    • Exergy-method analysis of a twostage vapour-compression refrigeration-plants performance
    • Nikolaidis C, Probert D. Exergy-method analysis of a twostage vapour-compression refrigeration-plants performance. Applied Energy 1998; 60:241-256.
    • (1998) Applied Energy , vol.60 , pp. 241-256
    • Nikolaidis, C.1    Probert, D.2
  • 23
    • 4944221350 scopus 로고    scopus 로고
    • Experimental performance analysis of a solar assisted ground-source heat pump greenhouse heating system
    • Ozgener O, Hepbasli A. Experimental performance analysis of a solar assisted ground-source heat pump greenhouse heating system. Energy and Buildings 2005; 37:101-110.
    • (2005) Energy and Buildings , vol.37 , pp. 101-110
    • Ozgener, O.1    Hepbasli, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.