메뉴 건너뛰기




Volumn 55, Issue 5, 2010, Pages 1391-1395

Predictors of depth of maximal insertion at double-balloon enteroscopy

Author keywords

Deep enteroscopy; Depth of maximal insertion; Double balloon enteroscopy

Indexed keywords

ABDOMINAL SURGERY; ADULT; ANALYSIS OF VARIANCE; APPENDECTOMY; ARTICLE; BODY MASS; CHOLECYSTECTOMY; DATA BASE; DOUBLE BALLOON ENTEROSCOPY; FEMALE; HERNIA; HUMAN; INTESTINE SURGERY; MAJOR CLINICAL STUDY; MALE; MULTIVARIATE ANALYSIS; PRIORITY JOURNAL; REGRESSION ANALYSIS; SURGICAL TECHNIQUE; UNIVARIATE ANALYSIS; UTERUS SURGERY; ABDOMEN; AGED; BALLOON DILATATION; CLINICAL COMPETENCE; GASTROINTESTINAL ENDOSCOPY; METHODOLOGY; MIDDLE AGED;

EID: 77953648155     PISSN: 01632116     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10620-009-0849-6     Document Type: Article
Times cited : (16)

References (20)
  • 2
    • 33748353610 scopus 로고    scopus 로고
    • Diagnostic yield and therapeutic impact of double-balloon enteroscopy in a large cohort of patients with obscure gastrointestinal bleeding
    • DOI 10.1111/j.1572-0241.2006.00664.x
    • Sun B, Rajan E, Cheng S, et al. Diagnostic yield and therapeutic impact of double-balloon enteroscopy in a large cohort of patients with obscure gastrointestinal bleeding. Am J Gastroenterol. 2006;101:2011-2015. doi:10.1111/j.1572-0241.2006.00664.x. (Pubitemid 44337625)
    • (2006) American Journal of Gastroenterology , vol.101 , Issue.9 , pp. 2011-2015
    • Sun, B.1    Rajan, E.2    Cheng, S.3    Shen, R.4    Zhang, C.5    Zhang, S.6    Wu, Y.7    Zhong, J.8
  • 4
    • 34447520127 scopus 로고    scopus 로고
    • Clinical outcomes after double-balloon enteroscopy in patients with obscure GI bleeding and a positive capsule endoscopy
    • DOI 10.1016/j.gie.2007.02.044, PII S0016510707003471
    • Kaffes AJ, Siah C, Koo JH. Clinical outcomes after double-balloon enteroscopy in patients with obscure GI bleeding and a positive capsule endoscopy. Gastrointest Endosc. 2007;66:304-309. doi:10.1016/j.gie.2007.02.044. (Pubitemid 47069297)
    • (2007) Gastrointestinal Endoscopy , vol.66 , Issue.2 , pp. 304-309
    • Kaffes, A.J.1    Siah, C.2    Koo, J.H.3
  • 5
    • 33847311757 scopus 로고    scopus 로고
    • Endoscopic interventions in the small bowel using double balloon enteroscopy: Feasibility and limitations
    • DOI 10.1111/j.1572-0241.2007.01063.x
    • May A, Nachbar L, Pohl J, Ell C. Endoscopic interventions in the small bowel using double-balloon enteroscopy: feasibility and limitations. Am J Gastroenterol. 2007;102:527-535. doi:10.1111/j.1572-0241.2007.01063.x. (Pubitemid 46328157)
    • (2007) American Journal of Gastroenterology , vol.102 , Issue.3 , pp. 527-535
    • May, A.1    Nachbar, L.2    Pohl, J.3    Ell, C.4
  • 6
    • 33748355828 scopus 로고    scopus 로고
    • Prospective comparison of push enteroscopy and push-and-pull enteroscopy in patients with suspected small-bowel bleeding
    • DOI 10.1111/j.1572-0241.2006.00745.x
    • May A, Nachbar L, Schneider M, Ell C. Prospective comparison of push enteroscopy and push-and-pull enteroscopy in patients with suspected small-bowel bleeding. Am J Gastroenterol. 2006;101:2016-2024. doi:10.1111/j.1572-0241.2006. 00745.x. (Pubitemid 44337626)
    • (2006) American Journal of Gastroenterology , vol.101 , Issue.9 , pp. 2016-2024
    • May, A.1    Nachbar, L.2    Schneider, M.3    Ell, C.4
  • 7
    • 44749086855 scopus 로고    scopus 로고
    • Double-balloon enteroscopy and capsule endoscopy have comparable diagnostic yield in small-bowel disease: a meta-analysis
    • doi:10.1016/j.cgh.2008.01.005
    • Pasha SF, Leighton JA, Das A, et al. Double-balloon enteroscopy and capsule endoscopy have comparable diagnostic yield in small-bowel disease: a meta-analysis. Clin Gastroenterol Hepatol. 2008;6:671-676. doi:10.1016/j.cgh. 2008.01.005.
    • (2008) Clin Gastroenterol Hepatol , vol.6 , pp. 671-676
    • Pasha, S.F.1    Leighton, J.A.2    Das, A.3
  • 8
    • 21544455840 scopus 로고    scopus 로고
    • Double-balloon enteroscopy (push-and-pull enteroscopy) of the small bowel: Feasibility and diagnostic and therapeutic yield in patients with suspected small bowel disease
    • DOI 10.1016/S0016-5107(05)01586-5, PII S0016510705015865
    • May A, Nachbar L, Ell C. Double-balloon enteroscopy (pushand-pull enteroscopy) of the small bowel: feasibility and diagnostic and therapeutic yield in patients with suspected small bowel disease. Gastrointest Endosc. 2005;62:62-70. doi:10.1016/S0016-5107(05)01586-5. (Pubitemid 40922442)
    • (2005) Gastrointestinal Endoscopy , vol.62 , Issue.1 , pp. 62-70
    • May, A.1    Nachbar, L.2    Ell, C.3
  • 9
    • 21644486673 scopus 로고    scopus 로고
    • Push-and-pull enteroscopy in the small bowel using the double-balloon technique: Results of a prospective European multicenter study
    • DOI 10.1055/s-2005-870126
    • Ell C, May A, Nachbar L, et al. Push-and-pull enteroscopy in the small bowel using the double-balloon technique: results of a prospective European multicenter study. Endoscopy. 2005;37: 613-616. doi:10.1055/s-2005-870126. (Pubitemid 40936494)
    • (2005) Endoscopy , vol.37 , Issue.7 , pp. 613-616
    • Ell, C.1    May, A.2    Nachbar, L.3    Cellier, C.4    Landi, B.5    Di Caro, S.6    Gasbarrini, A.7
  • 11
    • 30744458878 scopus 로고    scopus 로고
    • Double-balloon enteroscopy: Indications, diagnostic yield, and complications in a series of 275 patients with suspected small-bowel disease
    • DOI 10.1055/s-2005-921188
    • Heine GD, Hadithi M, Groenen MJ, Kuipers EJ, Jacobs MA, Mulder CJ. Double-balloon enteroscopy: indications, diagnostic yield, and complications in a series of 275 patients with suspected small-bowel disease. Endoscopy. 2006;38:42-48. doi:10.1055/s-2005-921188. (Pubitemid 43092703)
    • (2006) Endoscopy , vol.38 , Issue.1 , pp. 42-48
    • Heine, G.D.N.1    Hadithi, M.2    Groenen, M.J.M.3    Kuipers, E.J.4    Jacobs, M.A.J.M.5    Mulder, C.J.J.6
  • 12
    • 34047171990 scopus 로고    scopus 로고
    • A retrospective study of the application on double-balloon enteroscopy in 378 patients with suspected small-bowel diseases
    • DOI 10.1055/s-2007-966190
    • Zhong J, Ma T, Zhang C, et al. A retrospective study of the application on double-balloon enteroscopy in 378 patients with suspected small-bowel diseases. Endoscopy. 2007;39:208-215. doi:10.1055/s-2007-966190. (Pubitemid 46510791)
    • (2007) Endoscopy , vol.39 , Issue.3 , pp. 208-215
    • Zhong, J.1    Ma, T.2    Zhang, C.3    Sun, B.4    Chen, S.5    Cao, Y.6    Wu, Y.7
  • 14
    • 42649100629 scopus 로고    scopus 로고
    • Initial experience with double-balloon enteroscopy at a U.S. center
    • doi:10.1016/j.gie.2007.07.047
    • Gross SA, Stark ME. Initial experience with double-balloon enteroscopy at a U.S. center. Gastrointest Endosc. 2008;67:890-897. doi:10.1016/j.gie.2007.07. 047.
    • (2008) Gastrointest Endosc , vol.67 , pp. 890-897
    • Gross, S.A.1    Stark, M.E.2
  • 15
    • 33947310935 scopus 로고    scopus 로고
    • Success rate of retrograde double-balloon enteroscopy
    • DOI 10.1016/j.gie.2006.12.038, PII S001651070603553X
    • Mehdizadeh S, Han NJ, Cheng DW, Chen GC, Lo SK. Success rate of retrograde double-balloon enteroscopy. Gastrointest Endosc. 2007;65:633-639. doi:10.1016/j.gie.2006.12.038. (Pubitemid 46440921)
    • (2007) Gastrointestinal Endoscopy , vol.65 , Issue.4 , pp. 633-639
    • Mehdizadeh, S.1    Han, N.J.2    Cheng, D.W.3    Chen, G.C.4    Lo, S.K.5
  • 17
    • 12444251170 scopus 로고    scopus 로고
    • Push-andpull enteroscopy using the double-balloon technique: Method of assessing depth of insertion and training of the enteroscopy technique using the Erlangen Endo-Trainer
    • doi:10.1055/s-2004-826177
    • May A, Nachbar L, Schneider M, Neumann M, Ell C. Push-andpull enteroscopy using the double-balloon technique: method of assessing depth of insertion and training of the enteroscopy technique using the Erlangen Endo-Trainer. Endoscopy. 2005;37: 66-70. doi:10.1055/s-2004-826177.
    • (2005) Endoscopy , vol.37 , pp. 66-70
    • May, A.1    Nachbar, L.2    Schneider, M.3    Neumann, M.4    Ell, C.5
  • 18
    • 0034898354 scopus 로고    scopus 로고
    • Do we need the overtube for push-enteroscopy?
    • DOI 10.1055/s-2001-16208
    • Benz C, Jakobs R, Riemann JF. Do we need the overtube for push-enteroscopy? Endoscopy. 2001;33:658-661. doi:10.1055/s-2001-16208. (Pubitemid 32725156)
    • (2001) Endoscopy , vol.33 , Issue.8 , pp. 658-661
    • Benz, C.1    Jakobs, R.2    Riemann, J.F.3
  • 19
    • 0034958460 scopus 로고    scopus 로고
    • Use of an overtube for enteroscopy - Does it increase depth of insertion? A prospective study of enteroscopy with and without an overtube
    • DOI 10.1055/s-2001-12799
    • Taylor AC, Chen RY, Desmond PV. Use of an overtube for enteroscopy-does it increase depth of insertion? A prospective study of enteroscopy with and without an overtube. Endoscopy. 2001;33:227-230. doi:10.1055/s-2001-12799. (Pubitemid 32586396)
    • (2001) Endoscopy , vol.33 , Issue.3 , pp. 227-230
    • Taylor, A.C.F.1    Chen, R.Y.M.2    Desmond, P.V.3
  • 20
    • 42649109756 scopus 로고    scopus 로고
    • Double-balloon enteroscopy: ready for prime time?
    • DOI 10.1016/j.gie.2007.10.033, PII S0016510707029410
    • Kamal A. Double-balloon enteroscopy: ready for prime time? Gastrointest Endosc. 2008;67:898-901. doi:10.1016/j.gie.2007.10.033. (Pubitemid 351601749)
    • (2008) Gastrointestinal Endoscopy , vol.67 , Issue.6 , pp. 898-901
    • Kamal, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.