메뉴 건너뛰기




Volumn 27, Issue 2, 2010, Pages 127-135

Erratum to: Prospective multicenter randomized trial of fast ventricular tachycardia termination by prolonged versus conventional anti-tachyarrhythmia burst pacing in implantable cardioverter-defibrillator patients-Atp DeliVery for pAiNless ICD thErapy (ADVANCE-D) Trial results (Journal of Interventional Cardiac Electrophysiology 27:2 (127-135) DOI: 10.1007/s10840-009-9454-z);Prospective multicenter randomized trial of fast ventricular tachycardia termination by prolonged versus conventional anti-tachyarrhythmia burst pacing in implantable cardioverter-defibrillator patients-Atp deliVery for pAiNless ICD thErapy (ADVANCE-D) trial results

Author keywords

Defibrillators; Implantable; Pacing; Programming; Shock; Ventricular tachyarrhythmia

Indexed keywords

ADULT; ARTICLE; CARDIAC PATIENT; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DEFIBRILLATOR; DEVICE; ELECTROGRAPHY; FEMALE; FOLLOW UP; HEART FAILURE; HEART LEFT VENTRICLE EJECTION FRACTION; HEART PACING; HEART VENTRICLE TACHYCARDIA; HUMAN; IMPLANTATION; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MULTICENTER STUDY; POPULATION; PRIORITY JOURNAL; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL; SAFETY; SUPRAVENTRICULAR TACHYCARDIA; SYNCOPE; CARDIOVERSION; EUROPE; METHODOLOGY; MIDDLE AGED; MORTALITY; PREVALENCE; RISK ASSESSMENT; RISK FACTOR; SURVIVAL; SURVIVAL RATE; TREATMENT OUTCOME;

EID: 77953623659     PISSN: 1383875X     EISSN: 15728595     Source Type: Journal    
DOI: 10.1007/s10840-010-9495-3     Document Type: Erratum
Times cited : (52)

References (18)
  • 1
    • 0037149716 scopus 로고    scopus 로고
    • Multicenter Automatic Defibrillator Implantation Trial II Investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction
    • Moss, A. J., Zareba, W., Hall, W. J., et al. (2002). Multicenter Automatic Defibrillator Implantation Trial II Investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. New England Journal of Medicine, 346, 877-883.
    • (2002) New England Journal of Medicine , vol.346 , pp. 877-883
    • Moss, A.J.1    Zareba, W.2    Hall, W.J.3
  • 2
    • 19944429413 scopus 로고    scopus 로고
    • Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) Investigators. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure
    • Bardy, G. H., Lee, K. L., Mark, D. B., et al. (2005). Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) Investigators. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. New England Journal of Medicine, 52, 225-237.
    • (2005) New England Journal of Medicine , vol.52 , pp. 225-237
    • Bardy, G.H.1    Lee, K.L.2    Mark, D.B.3
  • 3
    • 0034088247 scopus 로고    scopus 로고
    • Assessing the psychosocial impact of the ICD: A national survey of implantable cardioverter defibrillator health care provides
    • Sears, S. F., Todaro, J. F., Urizar, G., et al. (2000). Assessing the psychosocial impact of the ICD: a national survey of implantable cardioverter defibrillator health care provides. Pacing and Clinical Electrophysiology, 23, 939-945.
    • (2000) Pacing and Clinical Electrophysiology , vol.23 , pp. 939-945
    • Sears, S.F.1    Todaro, J.F.2    Urizar, G.3
  • 4
    • 0027169147 scopus 로고
    • Patient acceptance of the implantable cardioverter-defibrillator in ventricular tachyarrhythmias
    • Luederitz, B., Jung, W., Deister, A., et al. (1993). Patient acceptance of the implantable cardioverter-defibrillator in ventricular tachyarrhythmias. Pacing and Clinical Electrophysiology, 16, 1815-1821.
    • (1993) Pacing and Clinical Electrophysiology , vol.16 , pp. 1815-1821
    • Luederitz, B.1    Jung, W.2    Deister, A.3
  • 5
    • 34250765769 scopus 로고    scopus 로고
    • The ICD shock and stress management program: A randomized trial of psychosocial treatment to optimize quality of life in ICD patients
    • Sears, S. F., Sowell, L. D. V., Kuhl, E. A., et al. (2007). The ICD shock and stress management program: a randomized trial of psychosocial treatment to optimize quality of life in ICD patients. Pacing and Clinical Electrophysiology, 30(7), 858-864.
    • (2007) Pacing and Clinical Electrophysiology , vol.30 , Issue.7 , pp. 858-864
    • Sears, S.F.1    Sowell, L.D.V.2    Kuhl, E.A.3
  • 6
  • 7
    • 19944430757 scopus 로고    scopus 로고
    • Fast ventricular tachycardias in patients with implantable cardioverterdefibrillators: Efficacy and safety of anti-tachycardia pacing
    • Jiménez-Candil, J., Arenal, A., García-Alberola, A., et al. (2005). Fast ventricular tachycardias in patients with implantable cardioverterdefibrillators: efficacy and safety of anti-tachycardia pacing. Journal of the American College of Cardiology, 45(3), 460-461.
    • (2005) Journal of the American College of Cardiology , vol.45 , Issue.3 , pp. 460-461
    • Jiménez-Candil, J.1    Arenal, A.2    García-Alberola, A.3
  • 8
    • 0032374070 scopus 로고    scopus 로고
    • Randomized prospective comparison of four burst pacing algorithms for spontaneous ventricular tachycardia
    • A8-9
    • Peinado, R., Almendral, J., Rius, T., et al. (1998). Randomized prospective comparison of four burst pacing algorithms for spontaneous ventricular tachycardia. American Journal of Cardiology, 82 (11), 1422-1425. A8-9.
    • (1998) American Journal of Cardiology , vol.82 , Issue.11 , pp. 1422-1425
    • Peinado, R.1    Almendral, J.2    Rius, T.3
  • 9
    • 33745685677 scopus 로고    scopus 로고
    • A comparison of empiric to physiciantailored programming of implantable cardioverter-defibrillators: Results from the prospective randomized multicenter EMPIRIC trial
    • EMPIRIC Trial Investigators
    • Wilkoff, B. L., Ousdigian, K. T., Sterns, L. D., et al. (2006). EMPIRIC Trial Investigators. A comparison of empiric to physiciantailored programming of implantable cardioverter-defibrillators: results from the prospective randomized multicenter EMPIRIC trial. Journal of the American College of Cardiology, 48, 330-339.
    • (2006) Journal of the American College of Cardiology , vol.48 , pp. 330-339
    • Wilkoff, B.L.1    Ousdigian, K.T.2    Sterns, L.D.3
  • 10
    • 48449088263 scopus 로고    scopus 로고
    • PREPARE Study Investigators. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: Results from the PREPARE (Primary Prevention Parameters Evaluation) study
    • Wilkoff, B. L.,Williamson, B. D., Stern, R. S., et al. (2008). PREPARE Study Investigators. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study. Journal of the American College of Cardiology, 52(7), 541-550.
    • (2008) Journal of the American College of Cardiology , vol.52 , Issue.7 , pp. 541-550
    • Wilkoff, B.L.1    Williamson, B.D.2    Stern, R.S.3
  • 11
    • 66649134745 scopus 로고    scopus 로고
    • Avoid delivering therapies for nonsustained fast ventricular tachyarrhythmia in patients with implantable cardioverter/defibrillator: The ADVANCE III Trial
    • Schwab, J. O., Gasparini, M., Lunati, M., et al. (2009). Avoid delivering therapies for nonsustained fast ventricular tachyarrhythmia in patients with implantable cardioverter/defibrillator: the ADVANCE III Trial. J Cardiovasc Electrophysiol, 20, 663-666.
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 663-666
    • Schwab, J.O.1    Gasparini, M.2    Lunati, M.3
  • 12
    • 33751380058 scopus 로고    scopus 로고
    • Improvement of quality of life by means of antitachycardia pacing: From painfree to the advance-d trial
    • Review
    • Lunati, M., Defaye, P., Mermi, J., et al. (2006). Improvement of quality of life by means of antitachycardia pacing: from Painfree to the ADVANCE-D trial. Pacing and Clinical Electrophysiology, 29(Suppl 2), S35-S39. Review.
    • (2006) Pacing and Clinical Electrophysiology , vol.29 , Issue.SUPPL.2
    • Lunati, M.1    Defaye, P.2    Mermi, J.3
  • 13
    • 77649173768 scopus 로고
    • Longitudinal data analysis using generalized linear models
    • Liang, K. Y. & Zeger, S. (1986). Longitudinal data analysis using generalized linear models. Biometrika, 73, 13-22.
    • (1986) Biometrika , vol.73 , pp. 13-22
    • Liang, K.Y.1    Zeger, S.2
  • 14
    • 0035859949 scopus 로고    scopus 로고
    • Shock reduction using antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with coronary artery disease
    • Wathen, M. S., Sweeney, M. O., DeGroot, P. J., et al. (2001). Shock reduction using antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with coronary artery disease. Circulation, 104(7), 796-801.
    • (2001) Circulation , vol.104 , Issue.7 , pp. 796-801
    • Wathen, M.S.1    Sweeney, M.O.2    DeGroot, P.J.3
  • 15
    • 7544220287 scopus 로고    scopus 로고
    • Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing fast ventricular tachycardia reduces shock therapies (Painfree Rx II) trial results
    • Wathen, M. S., DeGroot, P. J., Sweeney, M. O., et al. (2004). Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: pacing fast ventricular tachycardia reduces shock therapies (PainFREE Rx II) trial results. Circulation, 110(17), 2591-2596.
    • (2004) Circulation , vol.110 , Issue.17 , pp. 2591-2596
    • Wathen, M.S.1    DeGroot, P.J.2    Sweeney, M.O.3
  • 16
    • 50949090502 scopus 로고    scopus 로고
    • Prognostic importance of defibrillator shocks in patients with heart failure
    • Poole, J. E., Johnson, G. W., et al. (2008). Prognostic importance of defibrillator shocks in patients with heart failure. New England Journal of Medicine, 359, 1009-1017.
    • (2008) New England Journal of Medicine , vol.359 , pp. 1009-1017
    • Poole, J.E.1    Johnson, G.W.2
  • 17
    • 41149165849 scopus 로고    scopus 로고
    • Inappropriate implantable cardioverterdefibrillator shocks in the MADIT II study: Frequency, mechanisms, predictors, and survival impact
    • Daubert, J. P., Zareba, W., Cannom, D. S., for the MADIT II Investigators, et al. (2008). Inappropriate implantable cardioverterdefibrillator shocks in the MADIT II study: frequency, mechanisms, predictors, and survival impact. Journal of the American College of Cardiology, 51, 1357-65.8.
    • (2008) Journal of the American College of Cardiology , vol.51 , pp. 1357-1658
    • Daubert, J.P.1    Zareba, W.2    Cannom, D.S.3
  • 18
    • 70349469830 scopus 로고    scopus 로고
    • A randomized study to compare ramp versus burst antitachycardia pacing therapies to treat fast ventricular tachyarrhythmias in patients with implantable cardioverter-defibrillators: The PITAGORA ICD Trial
    • Gulizia, M. M., Piraino, L., Scherillo, M., et al. (2009). A randomized study to compare ramp versus burst antitachycardia pacing therapies to treat fast ventricular tachyarrhythmias in patients with implantable cardioverter-defibrillators: the PITAGORA ICD Trial. Feb 13 2009. Circ Arrhythmia Electrophhysiol, 2, 146-153.
    • (2009) Circ Arrhythmia Electrophhysiol , vol.2 , pp. 146-153
    • Gulizia, M.M.1    Piraino, L.2    Scherillo, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.