메뉴 건너뛰기




Volumn 39, Issue 1, 2010, Pages 86-88

A New Maneuver for Endotracheal Tube Insertion During Difficult Glidescope Intubation

Author keywords

difficult airway; emergency intubation; GlideScope ; intubation; RSI; video laryngoscope

Indexed keywords

ADULT; ARTICLE; CASE REPORT; DIFFICULT INTUBATION; ENDOTRACHEAL TUBE; FAILED INTUBATION; HUMAN; INTUBATION; LARYNGOSCOPE; LARYNGOSCOPY; MALE; PRIORITY JOURNAL; TRACHEA; ENDOTRACHEAL INTUBATION; MIDDLE AGED; PROCEDURES; VIDEORECORDING;

EID: 77953610584     PISSN: 07364679     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jemermed.2009.11.005     Document Type: Article
Times cited : (22)

References (12)
  • 1
    • 42449159772 scopus 로고    scopus 로고
    • Poor visualization during direct laryngoscopy and high upper lip bite test score are predictors of difficult intubation with the GlideScope videolaryngoscope
    • Tremblay M.H., Williams S., Robitaille A., and Drolet P. Poor visualization during direct laryngoscopy and high upper lip bite test score are predictors of difficult intubation with the GlideScope videolaryngoscope. Anesth Analg 106 (2008) 1495-1500
    • (2008) Anesth Analg , vol.106 , pp. 1495-1500
    • Tremblay, M.H.1    Williams, S.2    Robitaille, A.3    Drolet, P.4
  • 2
    • 58749099150 scopus 로고    scopus 로고
    • Laryngoscopy via Macintosh blade versus GlideScope: success rate and time for endotracheal intubation in untrained medical personnel
    • Nouruzi-Sedeh P., Schumann M., and Groeben H. Laryngoscopy via Macintosh blade versus GlideScope: success rate and time for endotracheal intubation in untrained medical personnel. Anesthesiology 110 (2009) 32-37
    • (2009) Anesthesiology , vol.110 , pp. 32-37
    • Nouruzi-Sedeh, P.1    Schumann, M.2    Groeben, H.3
  • 3
    • 16344374081 scopus 로고    scopus 로고
    • Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients
    • Cooper R.M., Pacey J.A., Bishop M.J., and McCluskey S.A. Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients. Can J Anaesth 52 (2005) 191-198
    • (2005) Can J Anaesth , vol.52 , pp. 191-198
    • Cooper, R.M.1    Pacey, J.A.2    Bishop, M.J.3    McCluskey, S.A.4
  • 4
    • 11444255353 scopus 로고    scopus 로고
    • The Glidescope system: a clinical assessment of performance
    • Rai M.R., Dering A., and Verghese C. The Glidescope system: a clinical assessment of performance. Anaesthesia 60 (2005) 60-64
    • (2005) Anaesthesia , vol.60 , pp. 60-64
    • Rai, M.R.1    Dering, A.2    Verghese, C.3
  • 5
    • 0003842409 scopus 로고    scopus 로고
    • Lippincott Williams and Wilkins, Philadelphia, PA
    • rd edn. (2008), Lippincott Williams and Wilkins, Philadelphia, PA
    • (2008) rd edn.
    • Walls, R.M.1    Murphey, M.F.2
  • 6
    • 33846644972 scopus 로고    scopus 로고
    • Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope
    • Jones P.M., Turkstra T.P., Armstrong K.P., et al. Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope. Can J Anaesth 54 (2007) 21-27
    • (2007) Can J Anaesth , vol.54 , pp. 21-27
    • Jones, P.M.1    Turkstra, T.P.2    Armstrong, K.P.3
  • 7
    • 38749083384 scopus 로고    scopus 로고
    • A maneuver to facilitate endotracheal intubation using the GlideScope [letter]
    • Cho J.E., and Kil H.K. A maneuver to facilitate endotracheal intubation using the GlideScope [letter]. Can J Anaesth 55 (2008) 56-57
    • (2008) Can J Anaesth , vol.55 , pp. 56-57
    • Cho, J.E.1    Kil, H.K.2
  • 9
    • 33747584599 scopus 로고    scopus 로고
    • More maneuvers to facilitate tracheal intubation with the GlideScope [letter]
    • Kramer D.C., and Osborn I.P. More maneuvers to facilitate tracheal intubation with the GlideScope [letter]. Can J Anaesth 53 (2006) 737
    • (2006) Can J Anaesth , vol.53 , pp. 737
    • Kramer, D.C.1    Osborn, I.P.2
  • 10
    • 36849057099 scopus 로고    scopus 로고
    • Considerations aimed at facilitating the use of the new GlideScope videolaryngoscope [letter reply]
    • Cooper R.M. Considerations aimed at facilitating the use of the new GlideScope videolaryngoscope [letter reply]. Can J Anaesth 52 (2005) 661-662
    • (2005) Can J Anaesth , vol.52 , pp. 661-662
    • Cooper, R.M.1
  • 11
    • 43449108565 scopus 로고    scopus 로고
    • Advancing the endotracheal tube smoothly when using the GlideScope [author reply]
    • Neustein S.M. Advancing the endotracheal tube smoothly when using the GlideScope [author reply]. Can J Anaesth 55 (2008) 314
    • (2008) Can J Anaesth , vol.55 , pp. 314
    • Neustein, S.M.1
  • 12
    • 41349091260 scopus 로고    scopus 로고
    • The GlideScope-specific rigid stylet to facilitate tracheal intubation with the Glidescope [author reply]
    • Neustein S.M. The GlideScope-specific rigid stylet to facilitate tracheal intubation with the Glidescope [author reply]. Can J Anaesth 55 (2008) 196-197
    • (2008) Can J Anaesth , vol.55 , pp. 196-197
    • Neustein, S.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.