메뉴 건너뛰기




Volumn 43, Issue 9, 2010, Pages 1840-1843

The efficacy of using vibrometry to detect osteointegration of the Agility total ankle

Author keywords

Ankle; Arthroplasty; Osteointegration; Ultrasound; Vibrometry

Indexed keywords

ARTHROPLASTIES; CLINICAL STUDY; DESIGN CRITERION; DOPPLER ULTRASOUND; DOPPLER ULTRASOUND TECHNIQUE; IMPLANT COMPONENTS; JOINT REPLACEMENT; LASER VIBROMETRY; OSTEOINTEGRATION; REHABILITATION PROGRAMS; SURGICAL TREATMENT; SURVIVAL RATE; TALAR COMPONENTS; TESTING RESULTS; TOTAL JOINT REPLACEMENT; VALIDATION METHODOLOGIES; VIBROMETRY;

EID: 77953541873     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2010.02.019     Document Type: Article
Times cited : (7)

References (18)
  • 1
    • 0031863277 scopus 로고    scopus 로고
    • The natural history of debonding of the femoral component from the cement and its effect on long-term survival of Charnley total hip replacements
    • Berry D.J., Harmsen W.A., Ilstrup D.M. The natural history of debonding of the femoral component from the cement and its effect on long-term survival of Charnley total hip replacements. Journal of Bone and Joint Surgery, American Volume 1998, 80(7):715-721.
    • (1998) Journal of Bone and Joint Surgery, American Volume , vol.80 , Issue.7 , pp. 715-721
    • Berry, D.J.1    Harmsen, W.A.2    Ilstrup, D.M.3
  • 2
    • 33750095467 scopus 로고    scopus 로고
    • CDC Morbidity and Mortality Weekly Report. 55(40)
    • CDC Morbidity and Mortality Weekly Report, 2006. 55(40), 1089-1092.
    • (2006) , pp. 1089-1092
  • 5
    • 0034997894 scopus 로고    scopus 로고
    • Accurate diagnosis of hip prosthesis loosening using a vibrational technique
    • Georgiou A.P., Cunningham J.L. Accurate diagnosis of hip prosthesis loosening using a vibrational technique. Clinical Biomechanics 2001, 16:315-323.
    • (2001) Clinical Biomechanics , vol.16 , pp. 315-323
    • Georgiou, A.P.1    Cunningham, J.L.2
  • 6
    • 35649020272 scopus 로고    scopus 로고
    • The Swedish Ankle Arthroplasty Register: an analysis of 531 arthroplasties between 1993 and 2005
    • Henricson A., Skoog A., Carlsson A. The Swedish Ankle Arthroplasty Register: an analysis of 531 arthroplasties between 1993 and 2005. Acta Orthopaedica 2007, 78(5):569-574.
    • (2007) Acta Orthopaedica , vol.78 , Issue.5 , pp. 569-574
    • Henricson, A.1    Skoog, A.2    Carlsson, A.3
  • 8
    • 0030271435 scopus 로고    scopus 로고
    • Vibration analysis in the detection of total hip prosthetic loosening
    • Li P.L.S., Jones N.B., Gregg P.J. Vibration analysis in the detection of total hip prosthetic loosening. Medical Engineering and Physics 1996, 18:596-600.
    • (1996) Medical Engineering and Physics , vol.18 , pp. 596-600
    • Li, P.L.S.1    Jones, N.B.2    Gregg, P.J.3
  • 10
    • 0001230527 scopus 로고
    • Experimental observation of the influence of contact nonlinearity on the reflection of bulk acoustic waves and the propagation of surface acoustic waves
    • Len K.S., Severin F.M., Solodov I.Y. Experimental observation of the influence of contact nonlinearity on the reflection of bulk acoustic waves and the propagation of surface acoustic waves. Soviet Physics-Acoustics 1992, 37(6):610-612.
    • (1992) Soviet Physics-Acoustics , vol.37 , Issue.6 , pp. 610-612
    • Len, K.S.1    Severin, F.M.2    Solodov, I.Y.3
  • 12
    • 33845642934 scopus 로고    scopus 로고
    • Total knee arthroplasty effectiveness in patients 55 years old and younger: osteoarthritis vs. rheumatoid arthritis
    • Ritter M.A., Lutgring J.D., Davis K.E., Faris P.M., Berend M.E. Total knee arthroplasty effectiveness in patients 55 years old and younger: osteoarthritis vs. rheumatoid arthritis. Knee 2007, 14(1):9-11.
    • (2007) Knee , vol.14 , Issue.1 , pp. 9-11
    • Ritter, M.A.1    Lutgring, J.D.2    Davis, K.E.3    Faris, P.M.4    Berend, M.E.5
  • 14
    • 0018325033 scopus 로고
    • Harmonic generation at an unbonded interface-I. Planar interface between semi-infinite elastic media
    • Richardson J.M. Harmonic generation at an unbonded interface-I. Planar interface between semi-infinite elastic media. International Journal of Engineering Science 1979, 17:73-85.
    • (1979) International Journal of Engineering Science , vol.17 , pp. 73-85
    • Richardson, J.M.1
  • 15
    • 35349003201 scopus 로고    scopus 로고
    • Comparison of reoperation rates following ankle arthrodesis and total ankle arthroplasty
    • SooHoo N.F., Zingmond D.S., Ko C.Y. Comparison of reoperation rates following ankle arthrodesis and total ankle arthroplasty. Journal of Bone and Joint Surgery, American Volume 2007, 89(10):2143-2149.
    • (2007) Journal of Bone and Joint Surgery, American Volume , vol.89 , Issue.10 , pp. 2143-2149
    • SooHoo, N.F.1    Zingmond, D.S.2    Ko, C.Y.3
  • 18
    • 0000920620 scopus 로고    scopus 로고
    • Nonlinear acoustic applications for material characterization: a review
    • Zheng Y., Maev R.G., Solodov I.Y. Nonlinear acoustic applications for material characterization: a review. Canadian Journal of Physics 1999, 77:927-967.
    • (1999) Canadian Journal of Physics , vol.77 , pp. 927-967
    • Zheng, Y.1    Maev, R.G.2    Solodov, I.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.