메뉴 건너뛰기




Volumn 37, Issue 6, 2010, Pages 2901-2909

Correction of motion artifacts in cone-beam CT using a patient-specific respiratory motion model

Author keywords

Cone beam computed tomography; Image guided radiation treatment; Liver cancer; Lung cancer; Organ motion

Indexed keywords

BIOLOGICAL ORGANS; DEFORMATION; DISEASES; IMAGE REGISTRATION; RADIOTHERAPY; RESPIRATORY MECHANICS; TUMORS;

EID: 77953494298     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3397460     Document Type: Article
Times cited : (102)

References (18)
  • 1
    • 20644454162 scopus 로고    scopus 로고
    • Emergent technologies for 3-dimensional image-guided radiation delivery
    • DOI 10.1016/j.semradonc.2005.01.003, PII S1053429605000056
    • D. A. Jaffray, " Emergent technologies for 3-dimensional image-guided radiation delivery.," Semin. Radiat. Oncol. ZZZZZZ 1053-4296 15, 208-216 (2005). 10.1016/j.semradonc.2005.01.003 (Pubitemid 40835962)
    • (2005) Seminars in Radiation Oncology , vol.15 , Issue.3 , pp. 208-216
    • Jaffray, D.A.1
  • 2
    • 17844379967 scopus 로고    scopus 로고
    • Respiratory correlated cone beam CT
    • DOI 10.1118/1.1869074
    • J. J. Sonke, L. Zijp, P. Remeijer, and M. Van Herk, " Respiratory correlated cone beam CT.," Med. Phys. MPHYA6 0094-2405 32, 1176-1186 (2005). 10.1118/1.1869074 (Pubitemid 40590074)
    • (2005) Medical Physics , vol.32 , Issue.4 , pp. 1176-1186
    • Sonke, J.-J.1    Zijp, L.2    Remeijer, P.3    Van Herk, M.4
  • 3
    • 33749387058 scopus 로고    scopus 로고
    • Four-dimensional cone-beam computed tomography using an on-board imager
    • DOI 10.1118/1.2349692
    • T. Li, L. Xing, P. Munro, C. McGuinness, M. Chao, Y. Yang, B. Loo, and A. Koong, " Four-dimensional cone-beam computed tomography using an on-board imager.," Med. Phys. MPHYA6 0094-2405 33, 3825-3833 (2006). 10.1118/1.2349692 (Pubitemid 44505107)
    • (2006) Medical Physics , vol.33 , Issue.10 , pp. 3825-3833
    • Li, T.1    Xing, L.2    Munro, P.3    McGuinness, C.4    Chao, M.5    Yang, Y.6    Loo, B.7    Koong, A.8
  • 4
    • 34548304925 scopus 로고    scopus 로고
    • Four-dimensional cone beam CT with adaptive gantry rotation and adaptive data sampling
    • DOI 10.1118/1.2767145
    • J. Lu, T. M. Guerrero, P. Munro, A. Jeung, P. C. Chi, P. Balter, X. R. Zhu, R. Mohan, and T. Pan, " Four-dimensional cone beam CT with adaptive gantry rotation and adaptive data sampling.," Med. Phys. MPHYA6 0094-2405 34, 3520-3529 (2007). 10.1118/1.2767145 (Pubitemid 47339749)
    • (2007) Medical Physics , vol.34 , Issue.9 , pp. 3520-3529
    • Lu, J.1    Guerrero, T.M.2    Munro, P.3    Jeung, A.4    Chi, P.-C.M.5    Balter, P.6    Zhu, X.R.7    Mohan, R.8    Pan, T.9
  • 7
    • 34548314251 scopus 로고    scopus 로고
    • Enhanced 4D cone-beam CT with inter-phase motion model
    • DOI 10.1118/1.2767144
    • T. Li, A. Koong, and L. Xing, " Enhanced 4D cone-beam CT with inter-phase motion model.," Med. Phys. MPHYA6 0094-2405 34, 3688-3695 (2007). 10.1118/1.2767144 (Pubitemid 47339766)
    • (2007) Medical Physics , vol.34 , Issue.9 , pp. 3688-3695
    • Li, T.1    Koong, A.2    Xing, L.3
  • 8
    • 66449124189 scopus 로고    scopus 로고
    • On-the-fly motion-compensated cone-beam CT using an a priori model of the respiratory motion
    • MPHYA6 0094-2405,. 10.1118/1.3115691
    • S. Rit, J. Wolthaus, M. Van Herk, and J. J. Sonke, " On-the-fly motion-compensated cone-beam CT using an a priori model of the respiratory motion.," Med. Phys. MPHYA6 0094-2405 36, 2283-2296 (2009). 10.1118/1.3115691
    • (2009) Med. Phys. , vol.36 , pp. 2283-2296
    • Rit, S.1    Wolthaus, J.2    Van Herk, M.3    Sonke, J.J.4
  • 9
    • 33748881638 scopus 로고    scopus 로고
    • Respiration correlated cone-beam computed tomography and 4DCT for evaluating target motion in Stereotactic Lung Radiation Therapy
    • DOI 10.1080/02841860600907345, PII W158212612X7X6J3
    • T. G. Purdie, D. J. Moseley, J. P. Bissonnette, M. B. Sharpe, K. Franks, A. Bezjak, and D. A. Jaffray, " Respiration correlated cone-beam computed tomography and 4DCT for evaluation target motion in stereotactic lung radiation therapy.," Acta Oncol. ACTOEL 0284-186X 45, 915-922 (2006). 10.1080/02841860600907345 (Pubitemid 44423140)
    • (2006) Acta Oncologica , vol.45 , Issue.7 , pp. 915-922
    • Purdie, T.G.1    Moseley, D.J.2    Bissonnette, J.-P.3    Sharpe, M.B.4    Franks, K.5    Bezjak, A.6    Jaffray, D.A.7
  • 10
    • 38349112015 scopus 로고    scopus 로고
    • Variability of four-dimensional computed tomography patient models
    • IOBPD3 0360-3016,. 10.1016/j.ijrob2007.08.067
    • J. -J. Sonke, J. Lebesque, and M. Van Herk, " Variability of four-dimensional computed tomography patient models.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 70, 590-598 (2008). 10.1016/j.ijrobp.2007. 08.067
    • (2008) Int. J. Radiat. Oncol., Biol., Phys. , vol.70 , pp. 590-598
    • Sonke, J.-J.1    Lebesque, J.2    Van Herk, M.3
  • 12
    • 36649020436 scopus 로고    scopus 로고
    • A patient-specific respiratory model of anatomical motion for radiation treatment planning
    • DOI 10.1118/1.2804576
    • Q. H. Zhang, A. Pevsner, A. Hertanto, Y. Hu, K. E. Rosenzweig, C. Ling, and G. Mageras, " A patient-specific respiratory model of anatomical motion for radiation treatment planning.," Med. Phys. MPHYA6 0094-2405 34, 4772-4781 (2007). 10.1118/1.2804576 (Pubitemid 350197716)
    • (2007) Medical Physics , vol.34 , Issue.12 , pp. 4772-4781
    • Zhang, Q.1    Pevsner, A.2    Hertanto, A.3    Hu, Y.-C.4    Rosenzweig, K.E.5    Ling, C.C.6    Mageras, G.S.7
  • 13
    • 4344692365 scopus 로고    scopus 로고
    • Fast free-form deformable registration via calculus of variations
    • DOI 10.1088/0031-9155/49/14/003, PII S0031915504758509
    • W. Lu, M. Chen, G. Olivera, K. Ruchala, and T. Mackie, " Fast free-form deformable registration via calculus of variations.," Phys. Med. Biol. PHMBA7 0031-9155 49, 3067-3087 (2004). 10.1088/0031-9155/49/14/003 (Pubitemid 39139997)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.14 , pp. 3067-3087
    • Lu, W.1    Chen, M.-L.2    Olivera, H.G.H.3    Ruchala, K.J.4    Mackie, T.R.5
  • 14
    • 0037706093 scopus 로고    scopus 로고
    • Development of a dynamic model for the lung lobes and airway tree in the NCAT phantom
    • IETNAE 0018-9499,. 10.1109/TNS.2003.812445
    • J. M. Garrity, W. P. Segars, S. B. Knisley, and B. M. W. Tsui, " Development of a dynamic model for the lung lobes and airway tree in the NCAT phantom.," IEEE Trans. Nucl. Sci. IETNAE 0018-9499 50, 378-383 (2003). 10.1109/TNS.2003.812445
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , pp. 378-383
    • Garrity, J.M.1    Segars, W.P.2    Knisley, S.B.3    Tsui, B.M.W.4
  • 15
    • 29144534097 scopus 로고    scopus 로고
    • Modelling individual geometric variation based on dominant eigenmodes of organ deformation: Implementation and evaluation
    • DOI 10.1088/0031-9155/50/24/009, PII S0031915505017835
    • M. Söhn, M. Birkner, D. Yan, and M. Alber, " Modeling individual geometric variation based on dominant eigenmodes of organ deformation: Implementation and evaluation.," Phys. Med. Biol. PHMBA7 0031-9155 50, 5893-5908 (2005). 10.1088/0031-9155/50/24/009 (Pubitemid 41795840)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.24 , pp. 5893-5908
    • Sohn, M.1    Birkner, M.2    Yan, D.3    Alber, M.4
  • 17
    • 85024799646 scopus 로고    scopus 로고
    • Streaking artifacts reduction in four-dimensional cone-beam computed tomography
    • MPHYA6 0094-2405,. 10.1118/1.2977736
    • S. Leng, J. Zambelli, R. Tolakanahalli, B. Nett, P. Munro, J. Star-Lack, B. Paliwal, and G. H. Chen, " Streaking artifacts reduction in four-dimensional cone-beam computed tomography.," Med. Phys. MPHYA6 0094-2405 35, 4649-4659 (2008). 10.1118/1.2977736
    • (2008) Med. Phys. , vol.35 , pp. 4649-4659
    • Leng, S.1    Zambelli, J.2    Tolakanahalli, R.3    Nett, B.4    Munro, P.5    Star-Lack, J.6    Paliwal, B.7    Chen, G.H.8
  • 18
    • 40049108623 scopus 로고    scopus 로고
    • A deformable phantom for 4D radiotherapy verification: Design and image registration evaluation
    • DOI 10.1118/1.2836417
    • M. Serban, E. Heath, G. Stroian, D. L. Collins, and J. Seuntjens, " A deformable phantom for 4D radiotherapy verification: Design and image registration evaluation.," Med. Phys. MPHYA6 0094-2405 35, 1094-1102 (2008). 10.1118/1.2836417 (Pubitemid 351322655)
    • (2008) Medical Physics , vol.35 , Issue.3 , pp. 1094-1102
    • Serban, M.1    Heath, E.2    Stroian, G.3    Collins, D.L.4    Seuntjens, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.