메뉴 건너뛰기




Volumn 38, Issue 1, 2010, Pages 91-97

A prospective randomised multicentre clinical comparison of a minimised perfusion circuit versus conventional cardiopulmonary bypass

Author keywords

Aortic valve replacement; Coronary artery bypass; Minimised perfusion circuits; Transfusion requirements

Indexed keywords

ADULT; AGED; AORTA VALVE REPLACEMENT; ARTICLE; CARDIOPULMONARY BYPASS; CLINICAL EFFECTIVENESS; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CORONARY ARTERY BYPASS GRAFT; ERYTHROCYTE TRANSFUSION; FEMALE; HEART ATRIUM FIBRILLATION; HEART RIGHT ATRIUM; HUMAN; MAJOR CLINICAL STUDY; MALE; MINIMIZED PERFUSION CIRCUIT; MULTICENTER STUDY; PERFUSION; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; SAFETY;

EID: 77953480481     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2010.01.035     Document Type: Article
Times cited : (40)

References (23)
  • 1
    • 0027411838 scopus 로고
    • Inflammatory response to cardiopulmonary bypass
    • Butler J., Rocker G.M., and Westaby S. Inflammatory response to cardiopulmonary bypass. Ann Thorac Surg 55 (1993) 552-559
    • (1993) Ann Thorac Surg , vol.55 , pp. 552-559
    • Butler, J.1    Rocker, G.M.2    Westaby, S.3
  • 2
    • 0036803163 scopus 로고    scopus 로고
    • Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation
    • Fromes Y., Gaillard D., Ponzio O., Chauffert M., Gerhardt M.F., Deleuze P., and Bical O. Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation. Eur J Cardiothorac Surg 22 (2002) 527-533
    • (2002) Eur J Cardiothorac Surg , vol.22 , pp. 527-533
    • Fromes, Y.1    Gaillard, D.2    Ponzio, O.3    Chauffert, M.4    Gerhardt, M.F.5    Deleuze, P.6    Bical, O.7
  • 4
    • 0023149123 scopus 로고
    • Organ dysfunction after cardiopulmonary bypass. A systemic inflammatory reaction initiated by the extracorporeal circuit
    • Westaby S. Organ dysfunction after cardiopulmonary bypass. A systemic inflammatory reaction initiated by the extracorporeal circuit. Intensive Care Med 13 (1987) 89-95
    • (1987) Intensive Care Med , vol.13 , pp. 89-95
    • Westaby, S.1
  • 6
    • 29144528843 scopus 로고    scopus 로고
    • Prospective randomized study comparing coronary artery bypass grafting with the new mini-extracorporeal circulation Jostra System or with a standard cardiopulmonary bypass
    • Remadi J.P., Rakotoarivelo Z., Marticho P., and Benamar A. Prospective randomized study comparing coronary artery bypass grafting with the new mini-extracorporeal circulation Jostra System or with a standard cardiopulmonary bypass. Am Heart J 151 (2006) 198
    • (2006) Am Heart J , vol.151 , pp. 198
    • Remadi, J.P.1    Rakotoarivelo, Z.2    Marticho, P.3    Benamar, A.4
  • 8
    • 4444242608 scopus 로고    scopus 로고
    • Aortic valve replacement with the minimal extracorporeal circulation (Jostra MECC System) versus standard cardiopulmonary bypass: a randomized prospective trial
    • Remadi J.P., Rakotoarivelo Z., Marticho P., Trojette F., Benamar A., Poulain H., and Tribouilloy C. Aortic valve replacement with the minimal extracorporeal circulation (Jostra MECC System) versus standard cardiopulmonary bypass: a randomized prospective trial. J Thorac Cardiovasc Surg 128 (2004) 436-441
    • (2004) J Thorac Cardiovasc Surg , vol.128 , pp. 436-441
    • Remadi, J.P.1    Rakotoarivelo, Z.2    Marticho, P.3    Trojette, F.4    Benamar, A.5    Poulain, H.6    Tribouilloy, C.7
  • 9
    • 67650173026 scopus 로고    scopus 로고
    • Comparison of minimally invasive closed circuit versus standard extracorporeal circulation for aortic valve replacement: a randomized study
    • Castiglioni A., Verzini A., Colangelo N., Nascimbene S., Laino G., and Alfieri O. Comparison of minimally invasive closed circuit versus standard extracorporeal circulation for aortic valve replacement: a randomized study. Interact Cardiovasc Thorac Surg 9 (2009) 27-41
    • (2009) Interact Cardiovasc Thorac Surg , vol.9 , pp. 27-41
    • Castiglioni, A.1    Verzini, A.2    Colangelo, N.3    Nascimbene, S.4    Laino, G.5    Alfieri, O.6
  • 10
    • 70349260329 scopus 로고    scopus 로고
    • Beneficial effects of modern perfusion concepts in aortic valve and aortic root surgery
    • Kutschka I., Skorpil J., El-Essawi A., Hajek T., and Harringer W. Beneficial effects of modern perfusion concepts in aortic valve and aortic root surgery. Perfusion 24 (2009) 37-44
    • (2009) Perfusion , vol.24 , pp. 37-44
    • Kutschka, I.1    Skorpil, J.2    El-Essawi, A.3    Hajek, T.4    Harringer, W.5
  • 11
    • 28344447156 scopus 로고    scopus 로고
    • Minimized cardiopulmonary bypass in coronary artery bypass surgery: marginal impact on inflammation and coagulation but loss of safety margins
    • Nollert G., Schwabenland I., Maktav D., Kur F., Christ F., Fraunberger P., Reichert B., and Vicol C. Minimized cardiopulmonary bypass in coronary artery bypass surgery: marginal impact on inflammation and coagulation but loss of safety margins. Ann Thorac Surg 80 (2005) 2326-2332
    • (2005) Ann Thorac Surg , vol.80 , pp. 2326-2332
    • Nollert, G.1    Schwabenland, I.2    Maktav, D.3    Kur, F.4    Christ, F.5    Fraunberger, P.6    Reichert, B.7    Vicol, C.8
  • 13
    • 0037973306 scopus 로고    scopus 로고
    • Adverse effects of low hematocrit during cardiopulmonary bypass in the adult: should current practice be changed?
    • Habib R., Zacharias A., Schwann T.A., Riordan C.J., Durham S.J., and Shah A. Adverse effects of low hematocrit during cardiopulmonary bypass in the adult: should current practice be changed?. J Thorac Cardiovasc Surg 125 (2003) 1438-1450
    • (2003) J Thorac Cardiovasc Surg , vol.125 , pp. 1438-1450
    • Habib, R.1    Zacharias, A.2    Schwann, T.A.3    Riordan, C.J.4    Durham, S.J.5    Shah, A.6
  • 15
    • 62649146066 scopus 로고    scopus 로고
    • A systemic review of biocompatible cardiopulmonary bypass circuits and clinical outcome
    • Ranucci M., Balduini A., Ditta A., Boncilli A., and Brozzi S. A systemic review of biocompatible cardiopulmonary bypass circuits and clinical outcome. Ann Thorac Surg 87 (2009) 1311-1319
    • (2009) Ann Thorac Surg , vol.87 , pp. 1311-1319
    • Ranucci, M.1    Balduini, A.2    Ditta, A.3    Boncilli, A.4    Brozzi, S.5
  • 16
    • 0036090385 scopus 로고    scopus 로고
    • Limitation of thrombin generation, platelet activation, and inflammation by elimination of cardiotomy suction in patients undergoing coronary artery bypass grafting treated with heparin bonded circuits
    • Aldea G., Slotow L., Chandler W., Triggs C., Vocelka C., Crockett G., Shin Y., Curtis W., and Verrier E. Limitation of thrombin generation, platelet activation, and inflammation by elimination of cardiotomy suction in patients undergoing coronary artery bypass grafting treated with heparin bonded circuits. J. Thorac Cardiovasc Surg 123 (2002) 742-755
    • (2002) J. Thorac Cardiovasc Surg , vol.123 , pp. 742-755
    • Aldea, G.1    Slotow, L.2    Chandler, W.3    Triggs, C.4    Vocelka, C.5    Crockett, G.6    Shin, Y.7    Curtis, W.8    Verrier, E.9
  • 17
    • 0041830678 scopus 로고    scopus 로고
    • The association of lowest hematocrit during cardiopulmonary bypass with acute renal injury after coronary artery bypass surgery
    • Swaminathan M., Phillips-Bute B., Conlon P., Smith P., Newman M., and Stafford-Smith M. The association of lowest hematocrit during cardiopulmonary bypass with acute renal injury after coronary artery bypass surgery. Ann Thorac Surg 76 (2003) 784-791
    • (2003) Ann Thorac Surg , vol.76 , pp. 784-791
    • Swaminathan, M.1    Phillips-Bute, B.2    Conlon, P.3    Smith, P.4    Newman, M.5    Stafford-Smith, M.6
  • 19
    • 33846426475 scopus 로고    scopus 로고
    • Minimizing cardiopulmonary bypass attenuates myocardial damage after cardiac surgery
    • Skrabal C., Steinhoff G., and Liebold A. Minimizing cardiopulmonary bypass attenuates myocardial damage after cardiac surgery. ASAIO J 53 (2007) 32-35
    • (2007) ASAIO J , vol.53 , pp. 32-35
    • Skrabal, C.1    Steinhoff, G.2    Liebold, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.