메뉴 건너뛰기




Volumn 7646, Issue , 2010, Pages

A bio-inspired flow sensor

Author keywords

micropillar; piezoelectric; sensor; turbulent flow

Indexed keywords

ACCURATE MEASUREMENT; BIO-INSPIRED; BIOINSPIRED SENSORS; FLOW CONDITION; FLOW TURBULENCE; FLOW-SENSORS; MICRO PILLARS; PIEZOELECTRIC; PIEZOELECTRIC ELEMENTS; PIEZOELECTRIC SENSORS; PROTOTYPE DESIGNS; REAL TIME SENSING; SENSING ELEMENTS; SENSING PRINCIPLE;

EID: 77953469159     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.849230     Document Type: Conference Paper
Times cited : (11)

References (14)
  • 1
    • 85008035393 scopus 로고    scopus 로고
    • Development of Carbon Nanotube-Based Sensors - A Review
    • February 2007
    • Benjamin Mahar, Cosmin Laslau, Ronnie Yip, and Yu Sun (2007). Development of Carbon Nanotube-Based Sensors - A Review, IEEE Sensors Journal, VOL. 7, NO. 2, February 2007, 266-284.
    • (2007) IEEE Sensors Journal , vol.7 , Issue.2 , pp. 266-284
    • Mahar, B.1    Laslau, C.2    Yip, R.3    Sun, Y.4
  • 2
    • 34247633154 scopus 로고    scopus 로고
    • Dynamic response of micro-pillar sensors measuring fluctuating wall-shear-stress
    • Brucker, Ch., D. Bauer and H. Chaves (2007). Dynamic response of micro-pillar sensors measuring fluctuating wall-shear-stress, Exp Fluids (2007) 42:737-749
    • (2007) Exp Fluids , vol.2007 , Issue.42 , pp. 737-749
    • Brucker, Ch.1    Bauer, D.2    Chaves, H.3
  • 3
    • 24144477558 scopus 로고    scopus 로고
    • Feasability study of wall shear stress imaging using microstructured surfaces with flexible micropillars
    • DOI 10.1007/s00348-005-1003-7
    • Brucker C, Spatz J, Schroder W (2005) Feasability study of wall shear stress imaging using microstructured surfaces with flexible micropillars. Exp Fluids 39:464-474 (Pubitemid 41240048)
    • (2005) Experiments in Fluids , vol.39 , Issue.2 , pp. 464-474
    • Brucker, Ch.1    Spatz, J.2    Schroder, W.3
  • 4
    • 22544442230 scopus 로고    scopus 로고
    • Dynamic calibration technique for thermal shear-stress sensors with mean flow
    • DOI 10.1007/s00348-005-0969-5
    • Chandrasekaran V, Cain A, Nishida T, Cattafesta LN, Sheplak M (2005) Dynamic calibration for thermal shear-stress sensors with mean flow. Exp Fluids 39:56-65 (Pubitemid 41009767)
    • (2005) Experiments in Fluids , vol.39 , Issue.1 , pp. 56-65
    • Chandrasekaran, V.1    Cain, A.2    Nishida, T.3    Cattafesta, L.N.4    Sheplak, M.5
  • 6
    • 44949164676 scopus 로고    scopus 로고
    • Lateral line nerve fibers do not code bulk water flow direction in turbulent flow
    • Chagnaud BP, Bleckmann H, HofmannMH (2008a) Lateral line nerve fibers do not code bulk water flow direction in turbulent flow. Zoology 111:204-217.
    • (2008) Zoology , vol.111 , pp. 204-217
    • Chagnaud, B.P.1    Bleckmann, H.2    Hofmann, M.H.3
  • 7
    • 43749111340 scopus 로고    scopus 로고
    • Measuring Flow Velocity and Flow Direction by Spatial and Temporal Analysis of Flow Fluctuations
    • Chagnaud, B.P., Brucker, C., Hofmann, M.H. and Bleckmann, H. (2008b). Measuring Flow Velocity and Flow Direction by Spatial and Temporal Analysis of Flow Fluctuations, The Journal of Neuroscience,28(17): 4479-4487
    • (2008) The Journal of Neuroscience , vol.28 , Issue.17 , pp. 4479-4487
    • Chagnaud, B.P.1    Brucker, C.2    Hofmann, M.H.3    Bleckmann, H.4
  • 8
    • 0024722563 scopus 로고
    • The temporal evolution of masking and frequency selectivity in the goldfish
    • Coombs S, Fay RR (1989) The temporal evolution of masking and frequency selectivity in the goldfish. J Acoust Soc Am 86:925-933.
    • (1989) J Acoust Soc Am , vol.86 , pp. 925-933
    • Coombs, S.1    Fay, R.R.2
  • 9
    • 0037436114 scopus 로고    scopus 로고
    • Carbon Nanotube Flow Sensors
    • 14 February 2003
    • Ghosh, S., A. K. Sood and N. Kumar (2003). Carbon Nanotube Flow Sensors, Science 14 February 2003:, Vol. 299. no. 5609, pp. 1042-1044.
    • (2003) Science , vol.299 , Issue.5609 , pp. 1042-1044
    • Ghosh, S.1    Sood, A.K.2    Kumar, N.3
  • 11
    • 38849151110 scopus 로고    scopus 로고
    • Mean wall-shear stress measurements using the micro-pillar shear-stress sensor MPS
    • 2008
    • Grobe S and Schroder W. (2008). Mean wall-shear stress measurements using the micro-pillar shear-stress sensor MPS, Measurement science & technology, 2008, vol. 19, no1,
    • (2008) Measurement Science & Technology , vol.19 , Issue.1
    • Grobe, S.1    Schroder, W.2
  • 12
    • 85008035393 scopus 로고    scopus 로고
    • Development of Carbon Nanotube-Based Sensors - A Review
    • February
    • Mahar, B., Cosmin Laslau, Ronnie Yip, and Yu Sun (2009). Development of Carbon Nanotube-Based Sensors - A Review, IEEE SENSORS JOURNAL, Vol. 7, No. 2, February 2007.
    • (2007) IEEE SENSORS JOURNAL , vol.7 , Issue.2
    • Mahar, B.1    Laslau, C.2    Yip, R.3    Sun, Y.4
  • 13
    • 0030695817 scopus 로고    scopus 로고
    • The lateral line can mediate rheotaxis in fish
    • DOI 10.1038/40135
    • Montgomery J, Baker CF, Carton AG (1997). The lateral line can mediate rheotaxis in fish. Nature 389:960-963. (Pubitemid 27485685)
    • (1997) Nature , vol.389 , Issue.6654 , pp. 960-963
    • Montgomery, J.C.1    Baker, C.F.2    Carton, A.G.3
  • 14
    • 0005751829 scopus 로고
    • Planning for a comprehensive bridge safety assurance program
    • Transportation Research Board, Washington, D.C.
    • Shirole, A. M., and Holt, R. C. (1991). "Planning for a comprehensive bridge safety assurance program." Transp. Res. Rec. No. 1290, Transportation Research Board, Washington, D.C., 137-142
    • (1991) Transp. Res. Rec. No. 1290 , pp. 137-142
    • Shirole, A.M.1    Holt, R.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.