메뉴 건너뛰기




Volumn 3, Issue 2, 2009, Pages 219-232

Near-infrared microspectroscopic analysis of rat skin tissue heterogeneity in relation to noninvasive glucose sensing

Author keywords

Near infrared microspectroscopic mapping; Noninvasive glucose sensing; Skin heterogeneity

Indexed keywords

COLLAGEN TYPE 1; KERATIN;

EID: 77953403519     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229680900300202     Document Type: Conference Paper
Times cited : (25)

References (22)
  • 1
    • 6044275963 scopus 로고    scopus 로고
    • Non-invasive glucose measurement technologies: An update from 1999 to the dawn of the new millennium
    • Khalil OS. Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium. Diabetes Technol Ther. 2004;6(5):660-97.
    • (2004) Diabetes Technol Ther , vol.6 , Issue.5 , pp. 660-697
    • Khalil, O.S.1
  • 2
    • 84887164182 scopus 로고    scopus 로고
    • Near-infrared spectroscopy for noninvasive glucose sensing
    • Cunningham D, Stenken JA, editors. Analytical chemistry of in vivo glucose measurements. in press
    • Arnold MA, Olesberg JT, Small GW. Near-infrared spectroscopy for noninvasive glucose sensing. In Cunningham D, Stenken JA, editors. Analytical chemistry of in vivo glucose measurements. Wiley Chemical Analysis Series; in press.
    • Wiley Chemical Analysis Series
    • Arnold, M.A.1    Olesberg, J.T.2    Small, G.W.3
  • 3
    • 84887191039 scopus 로고    scopus 로고
    • Non-invasive glucose sensing with Raman spectroscopy
    • Cunningham D, Stenken JA, editors. Analytical chemistry of in vivo glucose measurements. in press
    • Shih WC, Bechtel KL, Feld MS. Non-invasive glucose sensing with Raman spectroscopy. In Cunningham D, Stenken JA, editors. Analytical chemistry of in vivo glucose measurements. Wiley Chemical Analysis Series; in press.
    • Wiley Chemical Analysis Series
    • Shih, W.C.1    Bechtel, K.L.2    Feld, M.S.3
  • 4
    • 22144457131 scopus 로고    scopus 로고
    • A novel approach to non-invasive glucose measurement by mid-infrared spectroscopy: The combination of quantum cascade lasers (QCL) and photoacoustic detection
    • Von Lilienfeld-Toal H, Weidenmuller M, Xhelaj A, Mantele, W. A novel approach to non-invasive glucose measurement by mid-infrared spectroscopy: the combination of quantum cascade lasers (QCL) and photoacoustic detection. Vibration Spec. 2005;38:209-15.
    • (2005) Vibration Spec , vol.38 , pp. 209-215
    • Von Lilienfeld-Toal, H.1    Weidenmuller, M.2    Xhelaj, A.3    Mantele, W.4
  • 5
    • 24644444644 scopus 로고    scopus 로고
    • Noninvasive glucose sensing
    • Arnold MA, Small GW. Noninvasive glucose sensing. Anal Chem. 2005;77(17):5429-39.
    • (2005) Anal Chem , vol.77 , Issue.17 , pp. 5429-5439
    • Arnold, M.A.1    Small, G.W.2
  • 6
    • 17644407338 scopus 로고    scopus 로고
    • Modeling anisotropic light propagation in a realistic model of the human head
    • Heiskala J, Nissilä I, Neuvonen T, Järvenpää S, Somersalo E. Modeling anisotropic light propagation in a realistic model of the human head. Appl Opt. 2005;44(11):2049-57.
    • (2005) Appl Opt , vol.44 , Issue.11 , pp. 2049-2057
    • Heiskala, J.1    Nissilä, I.2    Neuvonen, T.3    Järvenpää, S.4    Somersalo, E.5
  • 8
    • 30044440884 scopus 로고    scopus 로고
    • In vivo near-infrared spectroscopy of rat skin tissue with varying blood glucose levels
    • Olesberg JT, Liu L, Van Zee V, Arnold MA. In vivo near-infrared spectroscopy of rat skin tissue with varying blood glucose levels. Anal Chem. 2006;78(1):215-23.
    • (2006) Anal Chem , vol.78 , Issue.1 , pp. 215-223
    • Olesberg, J.T.1    Liu, L.2    Van Zee, V.3    Arnold, M.A.4
  • 9
    • 0037623407 scopus 로고    scopus 로고
    • Determining water content in human nails with a portable near-infrared spectrometer
    • Egawa M, Fukuhara T, Takahashi M, Ozaki Y. Determining water content in human nails with a portable near-infrared spectrometer. Appl Spectrosc. 2003;57(4): 473-8.
    • (2003) Appl Spectrosc , vol.57 , Issue.4 , pp. 473-478
    • Egawa, M.1    Fukuhara, T.2    Takahashi, M.3    Ozaki, Y.4
  • 10
    • 33645571737 scopus 로고    scopus 로고
    • In vivo measurement of water content of the fingernail and its seasonal change
    • Egawa M, Ozaki Y, Takahashi M. In vivo measurement of water content of the fingernail and its seasonal change. Skin Res Tech. 2005;12(20):126-32.
    • (2005) Skin Res Tech , vol.12 , Issue.20 , pp. 126-132
    • Egawa, M.1    Ozaki, Y.2    Takahashi, M.3
  • 11
    • 0031603180 scopus 로고    scopus 로고
    • Phantoms for noninvasive blood glucose sensing with near infrared transmission spectroscopy
    • Burmeister J, Chung H, Arnold MA. Phantoms for noninvasive blood glucose sensing with near infrared transmission spectroscopy. Photochem Photobiol. 1998;67(1):50-5.
    • (1998) Photochem Photobiol , vol.67 , Issue.1 , pp. 50-55
    • Burmeister, J.1    Chung, H.2    Arnold, M.A.3
  • 12
    • 8344231560 scopus 로고    scopus 로고
    • Molar absorptivities of glucose and other biological molecules in aqueous solutions over the first overtone and combination regions of the near-infrared spectrum
    • Amerov AK, Chen J, Arnold MA. Molar absorptivities of glucose and other biological molecules in aqueous solutions over the first overtone and combination regions of the near-infrared spectrum. Appl Spectrosc. 2004;58(10):1195-204.
    • (2004) Appl Spectrosc , vol.58 , Issue.10 , pp. 1195-1204
    • Amerov, A.K.1    Chen, J.2    Arnold, M.A.3
  • 13
    • 4544357882 scopus 로고    scopus 로고
    • Comparison of combination and first overtone spectral regions for near infrared calibration models for glucose and other biomolecules in aqueous solutions
    • Chen J, Arnold MA, Small GW. Comparison of combination and first overtone spectral regions for near infrared calibration models for glucose and other biomolecules in aqueous solutions. Anal Chem. 2004;76(18):5405-13.
    • (2004) Anal Chem , vol.76 , Issue.18 , pp. 5405-5413
    • Chen, J.1    Arnold, M.A.2    Small, G.W.3
  • 14
    • 57149086868 scopus 로고    scopus 로고
    • Assessing and advancing technology for the noninvasive measurement of clinical glucose
    • Bai C, Graham TL, Arnold MA. Assessing and advancing technology for the noninvasive measurement of clinical glucose. Anal Lett. 2008;41:2773-93.
    • (2008) Anal Lett , vol.41 , pp. 2773-2793
    • Bai, C.1    Graham, T.L.2    Arnold, M.A.3
  • 15
    • 0037804147 scopus 로고    scopus 로고
    • Insights in the biochemical composition of skin as investigated by micro infrared spectroscopic imaging
    • Garidel P. Insights in the biochemical composition of skin as investigated by micro infrared spectroscopic imaging. PCCP. 2003;5:2673-9.
    • (2003) PCCP , vol.5 , pp. 2673-2679
    • Garidel, P.1
  • 16
    • 0031258437 scopus 로고    scopus 로고
    • Sensory and motor denervation influence epidermal thickness in rat foot glabrous skin
    • Li Y, Hsieh S, Chien H, Zhang X, McArthur JC, Griffin JW. Sensory and motor denervation influence epidermal thickness in rat foot glabrous skin. Exp Neurol. 1997;147(2): 452-62.
    • (1997) Exp Neurol , vol.147 , Issue.2 , pp. 452-462
    • Li, Y.1    Hsieh, S.2    Chien, H.3    Zhang, X.4    McArthur, J.C.5    Griffin, J.W.6
  • 18
    • 7244229617 scopus 로고    scopus 로고
    • A decade of vibrational micro-spectroscopy of human cells and tissue (1994-2004)
    • Diem M, Romeo M, Boydston-White S, Miljkovic M, Matthaus C. A decade of vibrational micro-spectroscopy of human cells and tissue (1994-2004). Analyst. 2004;129(10):880-5.
    • (2004) Analyst , vol.129 , Issue.10 , pp. 880-885
    • Diem, M.1    Romeo, M.2    Boydston-White, S.3    Miljkovic, M.4    Matthaus, C.5
  • 19
    • 0033743733 scopus 로고    scopus 로고
    • Comparison of the FT-IR mapping and imaging techniques applied to polymeric systems
    • Bhargava R, Wall BG, Koenig JL. Comparison of the FT-IR mapping and imaging techniques applied to polymeric systems. Appl Spectrosc. 2000;54:470-9.
    • (2000) Appl Spectrosc , vol.54 , pp. 470-479
    • Bhargava, R.1    Wall, B.G.2    Koenig, J.L.3
  • 20
    • 0034667813 scopus 로고    scopus 로고
    • Temperature insensitive near-infrared method for determination of protein concentration during protein crystal growth
    • Olesberg JT, Arnold MA, Hu SY, Wiencek JM. Temperature insensitive near-infrared method for determination of protein concentration during protein crystal growth. Anal Chem. 2000;72(20):4985-90.
    • (2000) Anal Chem , vol.72 , Issue.20 , pp. 4985-4990
    • Olesberg, J.T.1    Arnold, M.A.2    Hu, S.Y.3    Wiencek, J.M.4
  • 21
    • 0013770652 scopus 로고
    • The effect of sex and site on the composition of skin in the rat and mouse
    • Dickerson JW, John PM. The effect of sex and site on the composition of skin in the rat and mouse. Biochem J. 1964;92(2):364-8.
    • (1964) Biochem J , vol.92 , Issue.2 , pp. 364-368
    • Dickerson, J.W.1    John, P.M.2
  • 22
    • 40949164632 scopus 로고    scopus 로고
    • Comparison of rat epidermal keratinocyte organotypic culture (ROC) with intact human skin: Lipid composition and thermal phase behavior of the stratum corneum
    • Pappinen S, Hermansson M, Kuntsche J, Somerharju P, Wertz P, Urtti A, Suhonen M. Comparison of rat epidermal keratinocyte organotypic culture (ROC) with intact human skin: lipid composition and thermal phase behavior of the stratum corneum. Biochim Biophys Acta. 2008;1778(4):824-34.
    • (2008) Biochim Biophys Acta , vol.1778 , Issue.4 , pp. 824-834
    • Pappinen, S.1    Hermansson, M.2    Kuntsche, J.3    Somerharju, P.4    Wertz, P.5    Urtti, A.6    Suhonen, M.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.