On the efficiency of azimuthal and rotational splitting for Monte Carlo simulation of clinical linear accelerators

Author keywords

Linac; Monte Carlo; Radiotherapy; Splitting; Variance reduction

Indexed keywords

AZIMUTHAL ANGLE; LINAC; MONTE CARLO; MONTE CARLO SIMULATION; PARTICLE REDISTRIBUTION; PHASE SPACES; RADIATION TRANSPORT; ROTATIONAL SPLITTINGS; SAMPLING PROCESS; VARIANCE REDUCTION TECHNIQUES;

EID: 77953360137     PISSN: 0969806X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radphyschem.2010.03.020     Document Type: Article
Times cited : (21)

References (8)
  • 1
    • 70350679020 scopus 로고    scopus 로고
    • Comparison between PENELOPE and electron Monte Carlo simulations of electron fields used in the treatment of the conjunctival lymphoma
    • Brualla L., Palanco-Zamora R., Wittig A., Sempau J., Sauerwein W. Comparison between PENELOPE and electron Monte Carlo simulations of electron fields used in the treatment of the conjunctival lymphoma. Phys. Med. Biol. 2009, 54:5469-5481.
    • (2009) Phys. Med. Biol. , vol.54 , pp. 5469-5481
    • Brualla, L.1    Palanco-Zamora, R.2    Wittig, A.3    Sempau, J.4    Sauerwein, W.5
  • 2
    • 70249097082 scopus 로고    scopus 로고
    • Efficient Monte Carlo simulation of multileaf collimators using geometry-related variance-reduction techniques
    • Brualla L., Salvat F., Palanco-Zamora R. Efficient Monte Carlo simulation of multileaf collimators using geometry-related variance-reduction techniques. Phys. Med. Biol. 2009, 54:4131-4149.
    • (2009) Phys. Med. Biol. , vol.54 , pp. 4131-4149
    • Brualla, L.1    Salvat, F.2    Palanco-Zamora, R.3
  • 3
    • 34547362214 scopus 로고    scopus 로고
    • Azimuthal particle redistribution for the reduction of latent phase-space variance in Monte Carlo simulations
    • Bush K., Zavgorodni S.F., Beckham W.A. Azimuthal particle redistribution for the reduction of latent phase-space variance in Monte Carlo simulations. Phys. Med. Biol. 2007, 52:4345-4360.
    • (2007) Phys. Med. Biol. , vol.52 , pp. 4345-4360
    • Bush, K.1    Zavgorodni, S.F.2    Beckham, W.A.3
  • 4
    • 36649020653 scopus 로고    scopus 로고
    • Report of the AAPM task group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning
    • Chetty I.J., Curran B., Cygler J.E., et al. Report of the AAPM task group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning. Med. Phys. 2007, 34:4818-4853.
    • (2007) Med. Phys. , vol.34 , pp. 4818-4853
    • Chetty, I.J.1    Curran, B.2    Cygler, J.E.3
  • 5
    • 70349456405 scopus 로고    scopus 로고
    • AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code PENELOPE
    • Panettieri V., Barsoum P., Wetermark M., Brualla L., Lax I. AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code PENELOPE. Radiother. Oncol. 2009, 93:94-101.
    • (2009) Radiother. Oncol. , vol.93 , pp. 94-101
    • Panettieri, V.1    Barsoum, P.2    Wetermark, M.3    Brualla, L.4    Lax, I.5
  • 6
    • 33846618618 scopus 로고    scopus 로고
    • Monte Carlo treatment planning for photon and electron beams
    • Reynaert N., van der Marck S.C., Schaart D.R., et al. Monte Carlo treatment planning for photon and electron beams. Rad. Phys. Chem. 2007, 76:643-686.
    • (2007) Rad. Phys. Chem. , vol.76 , pp. 643-686
    • Reynaert, N.1    van der Marck, S.C.2    Schaart, D.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.