Volumn 139, Issue 1-3, 2010, Pages 180-185

Post-processing image filtration enabling dose reduction in standard abdominal CT

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL RADIOGRAPHY; ALGORITHM; ARTICLE; BODY BURDEN; COMPUTER ASSISTED DIAGNOSIS; COMPUTER ASSISTED TOMOGRAPHY; EVALUATION; HUMAN; IMAGE QUALITY; METHODOLOGY; RADIATION DOSE; RADIATION PROTECTION; RADIOMETRY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY;

EID: 77953350622     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/ncq086     Document Type: Article
Times cited : (11)

References (13)
  • 1
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomographyan increasing source of radiation exposure
    • Brenner, D. J. and Hall, E. J. Computed tomographyan increasing source of radiation exposure. N. Engl. J. Med. 357, 2277-2284 (2007).
    • (2007) N. Engl. J. Med. , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 2
    • 67650790313 scopus 로고    scopus 로고
    • Is body weight the most appropriate criterion pulmonary CT angiography? Analysis to select patients eligible for low-dose of objective and subjective image quality at 80 kVp in 100 patients
    • Szucs-Farkas, Z., Strautz, T., Patak, M. A., Kurmann, L., Vock, P. and Schindera, S. T. Is body weight the most appropriate criterion pulmonary CT angiography? Analysis to select patients eligible for low-dose of objective and subjective image quality at 80 kVp in 100 patients. Eur. Radiol. 19, 1914-1922 (2009).
    • (2009) Eur. Radiol. , vol.19 , pp. 1914-1922
    • Szucs-Farkas, Z.1    Strautz, T.2    Patak, M.A.3    Kurmann, L.4    Vock, P.5    Schindera, S.T.6
  • 4
    • 34250326683 scopus 로고    scopus 로고
    • The effect of dose reduction and feasibility of edge-preserving noise reduction on the detection of liver lesions using MSCT
    • Wessling, J., Esseling, R., Raupach, R., Fockenberg, S., Osada, N., Gerß, J., Heindel, W. and Fischbach, R. The effect of dose reduction and feasibility of edge-preserving noise reduction on the detection of liver lesions using MSCT.Eur.Radiol.17, 1885-1891 (2007).
    • (2007) Eur. Radiol , vol.17 , pp. 1885-1891
    • Wessling, J.1    Esseling, R.2    Raupach, R.3    Fockenberg, S.4    Osada, N.5    Gerß, J.6    Heindel, W.7    Fischbach, R.8
  • 5
    • 4143148392 scopus 로고    scopus 로고
    • Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters
    • Kalra, M. K., Maher, M. M., Blake, M. A., Lucey, B. C., Karau, K., Toth, T. L., Avinash, G., Halpern, E. F. and Saini, S. Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters. Radiology 232, 791-797 (2004).
    • (2004) Radiology , vol.232 , pp. 791-797
    • Kalra, M.K.1    Maher, M.M.2    Blake, M.A.3    Lucey, B.C.4    Karau, K.5    Toth, T.L.6    Avinash, G.7    Halpern, E.F.8    Saini, S.9
  • 6
    • 0018026724 scopus 로고
    • In search of a general picture processing operator
    • Granlund, G. H. In search of a general picture processing operator. Comput. Graph. Image Process. 8, 155-173 (1978).
    • (1978) Comput. Graph. Image Process. , vol.8 , pp. 155-173
    • Granlund, G.H.1
  • 7
    • 42449117218 scopus 로고    scopus 로고
    • Reduction in dose from CT examinations of liver lesions with a new post-processing filter: AROC phantom study
    • Trægdemartinsen, A. C., Kjernliesæther, H., Olsen, D. R., Skaane, P. and Olerud, H. M. Reduction in dose from CT examinations of liver lesions with a new post-processing filter: AROC phantom study. Acta Radiol. 49, 303-309 (2008).
    • (2008) Acta Radiol , vol.49 , pp. 303-309
    • Trægdemartinsen, A.C.1    Kjernliesæther, H.2    Olsen, D.R.3    Skaane, P.4    Olerud, H.M.5
  • 9
    • 34347238949 scopus 로고    scopus 로고
    • Visual grading characteristics (VGC) analysis: a non-parametric rank-invariant statistical method for image quality evaluation
    • Båth, M. and Månsson, L. G. Visual grading characteristics (VGC) analysis: a non-parametric rank-invariant statistical method for image quality evaluation. Br. J. Radiol. 80, 169-176 (2007).
    • (2007) Br. J. Radiol. , vol.80 , pp. 169-176
    • Båth, M.1    Månsson, L.G.2
  • 10
    • 42649135155 scopus 로고    scopus 로고
    • Clinical evaluation of a dual-side readout technique computed radiography system in chest radiography of premature neonates
    • Carlander, A., Hansson, J., Söderberg, J., Steneryd, K. and Båth, M. Clinical evaluation of a dual-side readout technique computed radiography system in chest radiography of premature neonates. Acta Radiol. 4, 468-474 (2008).
    • (2008) Acta Radiol , vol.4 , pp. 468-474
    • Carlander, A.1    Hansson, J.2    Söderberg, J.3    Steneryd, K.4    Båth, M.5
  • 11
    • 77953336125 scopus 로고    scopus 로고
    • European guidelines on quality criteria for computed tomography
    • European guidelines on quality criteria for computed tomography. http://www.drs.dk/guidelines/ct/quality/htmlindex.htm
  • 12
    • 21244499800 scopus 로고    scopus 로고
    • A software tool for increased efficiency in observer performance studies in radiology
    • Börjesson, S. et al. A software tool for increased efficiency in observer performance studies in radiology. Radiat. Prot. Dosimetry 114, 45-52 (2005).
    • (2005) Radiat. Prot. Dosimetry , vol.114 , pp. 45-52
    • Börjesson, S.1
  • 13
    • 77952094734 scopus 로고    scopus 로고
    • CARE Dose 4D new technique for radiation dose reduction
    • Kalra, M. K. and and Brady, T. J. CARE Dose 4D new technique for radiation dose reduction. SOMATOM Sessions 19, 28-31 (2006).
    • (2006) SOMATOM Sessions , vol.19 , pp. 28-31
    • Kalra, M.K.1    Brady, T.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.