Volumn 97, Issue 1-2, 2010, Pages 292-298

Evaluation of operating parameters involved in solar photo-Fenton treatment of wastewater: Interdependence of initial pollutant concentration, temperature and iron concentration

Author keywords

Advanced oxidation processes; Hydrogen peroxide; Pesticides; Solar photocatalysis

Indexed keywords

ADVANCED OXIDATION PROCESSES; COMPOUND PARABOLIC COLLECTOR; CONCENTRATION OF; DIFFERENT PROCESS; DISSOLVED IRON; DISSOLVED ORGANIC CARBON; IRON CONCENTRATIONS; OPERATING PARAMETERS; OPERATING TEMPERATURE; ORGANICS; PHOTO-FENTON; POLLUTANT CONCENTRATION; SOLAR PHOTOCATALYSIS; SOLAR PLANT; TREATMENT TIME;