Failed videolaryngoscope intubation in a patient with diffuse idiopathic skeletal hyperostosis and spinal cord injury

Author keywords

[No Author keywords available]

Indexed keywords

AGED; AIRWAY OBSTRUCTION; ARTICLE; ARTIFICIAL VENTILATION; BRONCHOSCOPE; CASE REPORT; DIAGNOSTIC IMAGING; DIGESTIVE TRACT INTUBATION; EMPHYSEMA; ENDOTRACHEAL INTUBATION; FALLING; FIBEROSCOPE; GLASGOW COMA SCALE; HUMAN; HYPEROSTOSIS; LAMINOPLASTY; LARYNGEAL MASK; LARYNGOSCOPE; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUADRIPLEGIA; SPINAL CORD DECOMPRESSION; SPINAL CORD INJURY; TRACHEOSTOMY;

EID: 77953292424     PISSN: 0832610X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s12630-010-9313-5     Document Type: Article
Times cited : (16)

References (15)
  • 1
    • 2142712605 scopus 로고    scopus 로고
    • New developments in our understanding of DISH (diffuse idiopathic skeletal hyperostosis)
    • P Sarzi-Puttini F Atzeni 2004 New developments in our understanding of DISH (diffuse idiopathic skeletal hyperostosis) Curr Opin Rheumatol 16 287 292
    • (2004) Curr Opin Rheumatol , vol.16 , pp. 287-292
    • Sarzi-Puttini, P.1    Atzeni, F.2
  • 2
    • 0017155837 scopus 로고
    • Radiographic and pathologic features of spinal involvement in diffuse idiopathic skeletal hyperostosis (DISH)
    • 1:STN:280:DyaE283itlamtw%3D%3D 935390
    • D Resnick G Niwayama 1976 Radiographic and pathologic features of spinal involvement in diffuse idiopathic skeletal hyperostosis (DISH) Radiology 119 559 568 1:STN:280:DyaE283itlamtw%3D%3D 935390
    • (1976) Radiology , vol.119 , pp. 559-568
    • Resnick, D.1    Niwayama, G.2
  • 3
    • 33646843395 scopus 로고    scopus 로고
    • Diffuse Idiopathic Skeletal Hyperostosis: A Rare Cause of Dysphagia, Airway Obstruction, and Dysphonia
    • DOI 10.1016/j.jamcollsurg.2006.02.030, PII S1072751506001918
    • RS Nelson AC Urquhart T Faciszewski 2006 Diffuse idiopathic skeletal hyperostosis: a rare cause of dysphagia, airway obstruction, and dysphonia J Am Coll Surg 202 938 942 10.1016/j.jamcollsurg.2006.02.030 16735209 (Pubitemid 43776430)
    • (2006) Journal of the American College of Surgeons , vol.202 , Issue.6 , pp. 938-942
    • Nelson, R.S.1    Urquhart, A.C.2    Faciszewski, T.3
  • 4
    • 0027510553 scopus 로고
    • Diffuse idiopathic skeletal hyperostosis: An unusual cause of difficult intubation
    • 10.1007/BF03009319 1:STN:280:DyaK3s7ksFeqtw%3D%3D 8425244
    • E Crosby S Grahovac 1993 Diffuse idiopathic skeletal hyperostosis: an unusual cause of difficult intubation Can J Anaesth 40 54 58 10.1007/BF03009319 1:STN:280:DyaK3s7ksFeqtw%3D%3D 8425244
    • (1993) Can J Anaesth , vol.40 , pp. 54-58
    • Crosby, E.1    Grahovac, S.2
  • 5
    • 0242270103 scopus 로고    scopus 로고
    • Management of respiratory compromise caused by cervical osteophytes: A case report and review of the literature
    • DOI 10.1016/S1529-9430(02)00205-X, PII S152994300200205X
    • AJ Matan J Hsu BA Fredrickson 2002 Management of respiratory compromise caused by cervical osteophytes: a case report and review of the literature Spine J 2 456 459 10.1016/S1529-9430(02)00205-X 14589272 (Pubitemid 38351690)
    • (2002) Spine Journal , vol.2 , Issue.6 , pp. 456-459
    • Matan, A.J.1    Hsu, J.2    Fredrickson, B.A.3
  • 6
    • 0023205944 scopus 로고
    • Cervical spinal stenosis: Determination with vertebral body ratio method
    • 1:STN:280:DyaL2s3ptVGksA%3D%3D 3615879
    • H Pavlov JS Torg B Robie C Jahre 1987 Cervical spinal stenosis: determination with vertebral body ratio method Radiology 164 771 775 1:STN:280:DyaL2s3ptVGksA%3D%3D 3615879
    • (1987) Radiology , vol.164 , pp. 771-775
    • Pavlov, H.1    Torg, J.S.2    Robie, B.3    Jahre, C.4
  • 7
    • 0029117753 scopus 로고
    • Difficult direct laryngoscopy in patients with cervical spine disease
    • 10.1111/j.1365-2044.1995.tb06135.x 1:STN:280:DyaK28%2FhsVGjtg%3D%3D 7573863
    • I Calder J Calder HA Crockard 1995 Difficult direct laryngoscopy in patients with cervical spine disease Anaesthesia 50 756 763 10.1111/j.1365-2044. 1995.tb06135.x 1:STN:280:DyaK28%2FhsVGjtg%3D%3D 7573863
    • (1995) Anaesthesia , vol.50 , pp. 756-763
    • Calder, I.1    Calder, J.2    Crockard, H.A.3
  • 8
    • 41149178779 scopus 로고    scopus 로고
    • Predictors of difficult intubation in patients with cervical spine limitations
    • DOI 10.1097/ANA.0b013e318166dd00, PII 0000850620080400000005
    • GA Mashour ML Stallmer S Kheterpal A Shanks 2008 Predictors of difficult intubation in patients with cervical spine limitations J Neurosurg Anesthesiol 20 110 115 10.1097/ANA.0b013e318166dd00 18362772 (Pubitemid 351440982)
    • (2008) Journal of Neurosurgical Anesthesiology , vol.20 , Issue.2 , pp. 110-115
    • Mashour, G.A.1    Stallmer, M.L.2    Kheterpal, S.3    Shanks, A.4
  • 9
    • 33744959276 scopus 로고    scopus 로고
    • Airway management in adults after cervical spine trauma
    • DOI 10.1097/00000542-200606000-00026, PII 0000054220060600000026
    • ET Crosby 2006 Airway management in adults after cervical spine trauma Anesthesiology 104 1293 1318 10.1097/00000542-200606000-00026 16732102 (Pubitemid 43852964)
    • (2006) Anesthesiology , vol.104 , Issue.6 , pp. 1293-1318
    • Crosby, E.T.1
  • 10
    • 67349092219 scopus 로고    scopus 로고
    • Effect of manual in-line stabilization of the cervical spine in adults on the rate of difficult intubation by direct laryngoscopy: A randomized controlled trial
    • 10.1007/s12630-009-9089-7 19396507
    • F Thiboutot PC Nicole CA Trepanier AF Turgeon MR Lessard 2009 Effect of manual in-line stabilization of the cervical spine in adults on the rate of difficult intubation by direct laryngoscopy: a randomized controlled trial Can J Anesth 56 412 418 10.1007/s12630-009-9089-7 19396507
    • (2009) Can J Anesth , vol.56 , pp. 412-418
    • Thiboutot, F.1    Nicole, P.C.2    Trepanier, C.A.3    Turgeon, A.F.4    Lessard, M.R.5
  • 11
    • 39749120846 scopus 로고    scopus 로고
    • Cervical spine motion during tracheal intubation with manual in-line stabilization: Direct laryngoscopy versus GlideScope® videolaryngoscopy
    • DOI 10.1213/ane.0b013e318161769e, PII 0000053920080300000038
    • A Robitaille SR Williams MH Tremblay F Guilbert M Theriault P Drolet 2008 Cervical spine motion during tracheal intubation with manual in-line stabilization: direct laryngoscopy versus Glidescope videolaryngoscopy Anesth Analg 106 935 941 10.1213/ane.0b013e318161769e 18292443 (Pubitemid 351301419)
    • (2008) Anesthesia and Analgesia , vol.106 , Issue.3 , pp. 935-941
    • Robitaille, A.1    Williams, S.R.2    Tremblay, M.-H.3    Guilbert, F.4    Theriault, M.5    Drolet, P.6
  • 12
    • 38349068477 scopus 로고    scopus 로고
    • A proposed model for direct laryngoscopy and tracheal intubation
    • 10.1111/j.1365-2044.2008.05662-1.x 1:STN:280:DC%2BD1c%2Fmt1Kktg%3D%3D 18211447
    • KB Greenland 2008 A proposed model for direct laryngoscopy and tracheal intubation Anaesthesia 63 156 161 10.1111/j.1365-2044.2008.05662-1.x 1:STN:280:DC%2BD1c%2Fmt1Kktg%3D%3D 18211447
    • (2008) Anaesthesia , vol.63 , pp. 156-161
    • Greenland, K.B.1
  • 13
    • 33748074145 scopus 로고    scopus 로고
    • The use of the GlideScope® for tracheal intubation in patients with ankylosing spondylitis
    • DOI 10.1093/bja/ael133
    • HY Lai IH Chen A Chen FY Hwang Y Lee 2006 The use of the Glidescope for tracheal intubation in patients with ankylosing spondylitis Br J Anaesth 97 419 422 10.1093/bja/ael133 1:STN:280:DC%2BD28vnt1eisg%3D%3D 16829671 (Pubitemid 44295683)
    • (2006) British Journal of Anaesthesia , vol.97 , Issue.3 , pp. 419-422
    • Lai, H.Y.1    Chen, I.H.2    Chen, A.3    Hwang, F.Y.4    Lee, Y.5
  • 14
    • 33846605602 scopus 로고    scopus 로고
    • Complications associated with the use of the glideScope videolaryngoscope
    • 10.1007/BF03021900 17197469
    • RM Cooper 2007 Complications associated with the use of the GlideScope videolaryngoscope Can J Anaesth 54 54 57 10.1007/BF03021900 17197469
    • (2007) Can J Anaesth , vol.54 , pp. 54-57
    • Cooper, R.M.1
  • 15
    • 34249035445 scopus 로고    scopus 로고
    • Anterior tonsillar pillar perforation during Glidescope® video laryngoscopy [25]
    • DOI 10.1213/01.ane.0000266436.19478.1b, PII 0000053920070600000076
    • JA Pacey 2007 Anterior tonsillar pillar perforation during GlideScope video laryngoscopy (In response) Anesth Analg 104 1611 10.1213/01.ane. 0000266436.19478.1b (Pubitemid 46791335)
    • (2007) Anesthesia and Analgesia , vol.104 , Issue.6 , pp. 1611
    • Pacey, J.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.