메뉴 건너뛰기




Volumn 7642, Issue , 2010, Pages

Hydrostatically coupled dielectric elastomer actuators for tactile displays and cutaneous stimulators

Author keywords

Actuator; Bubble; Dielectric elastomer; Fluid; Hydrostatic; Liquid; Millimeter

Indexed keywords

ACTIVE PARTS; BUBBLE; DIELECTRIC ELASTOMER; DIELECTRIC ELASTOMER ACTUATORS; DIELECTRIC ELASTOMERS; ELECTRICAL SAFETY; HYDROSTATIC COUPLING; INCOMPRESSIBLE FLUID; INTERNAL FLUID; INTERNAL FLUID PRESSURE; MAXIMUM SENSITIVITY; MECHANORECEPTORS; OPTIMUM CONDITIONS; PASSIVE INTERFACES; RESONANCE FREQUENCIES; TACTILE DISPLAY; TACTILE INFORMATION; TRANSMISSION MECHANISMS;

EID: 77953280201     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.847562     Document Type: Conference Paper
Times cited : (11)

References (9)
  • 1
    • 0034603132 scopus 로고    scopus 로고
    • High-speed electrically actuated elastomers with strain greater than 100%
    • DOI 10.1126/science.287.5454.836
    • Pelrine, R. E, Kornbluh, R. D., Pei, Q. and Joseph, J. P., "High-speed electrically actuated elastomers with strain greater than 100%", Science 287, 836-839 (2000). (Pubitemid 30084322)
    • (2000) Science , vol.287 , Issue.5454 , pp. 836-839
    • Pelrine, R.1    Kornbluh, R.2    Pei, Q.3    Joseph, J.4
  • 2
    • 84983495160 scopus 로고    scopus 로고
    • Carpi, F., De Rossi, D., Kornbluh, R., Pelrine, R. and Sommer-Larsen, P., Ed., Elsevier, Amsterdam
    • Carpi, F., De Rossi, D., Kornbluh, R., Pelrine, R. and Sommer-Larsen, P., Ed., [Dielectric elastomers as electromechanical transducers], Elsevier, Amsterdam (2008).
    • (2008) Dielectric Elastomers As Electromechanical Transducers
  • 3
    • 77950594683 scopus 로고    scopus 로고
    • Hydrostatically coupled dielectric elastomer actuators
    • In press, Digital Object Identifier: 10.1109/TMECH.2009.2021651
    • Carpi, F., Frediani, G., De Rossi, D., "Hydrostatically coupled dielectric elastomer actuators", IEEE/ASME Transactions On Mechatronics, In press, Digital Object Identifier: 10.1109/TMECH.2009.2021651.
    • IEEE/ASME Transactions on Mechatronics
    • Carpi, F.1    Frediani, G.2    De Rossi, D.3
  • 4
    • 77953330145 scopus 로고    scopus 로고
    • Millimeter-scale bubble-like dielectric elastomer actuators
    • Carpi, F., Frediani, G., Tarantino, S., De Rossi, D., "Millimeter-scale bubble-like dielectric elastomer actuators", Polymer International 59(3), 407-414 (2010).
    • (2010) Polymer International , vol.59 , Issue.3 , pp. 407414
    • Carpi, F.1    Frediani, G.2    Tarantino, S.3    De Rossi, D.4
  • 6
    • 84890692832 scopus 로고    scopus 로고
    • A Braille display system for the visually disabled using a polymer based soft actuator
    • Carpi, F., Smela, E., Ed., Wiley, Chichester
    • Choi, H. R. et al. "A Braille display system for the visually disabled using a polymer based soft actuator", [Biomedical Applications of Electroactive Polymer Actuators], Carpi, F., Smela, E., Ed., Wiley, Chichester (2009).
    • (2009) Biomedical Applications of Electroactive Polymer Actuators
    • Choi, H.R.1
  • 7
    • 77953337374 scopus 로고    scopus 로고
    • Buckling actuators with integrated displacement sensor
    • Carpi, F., De Rossi, D. Kornbluh, R., Pelrine, R. and Sommer-Larsen, P., Ed., Elsevier, Amsterdam
    • Carpi, F., Fantoni, G., Frediani, G., De Rossi, D., "Buckling actuators with integrated displacement sensor", [Dielectric elastomers as electromechanical transducers], Carpi, F., De Rossi, D., Kornbluh, R., Pelrine, R. and Sommer-Larsen, P., Ed., Elsevier, Amsterdam (2008).
    • (2008) Dielectric Elastomers As Electromechanical Transducers
    • Carpi, F.1    Fantoni, G.2    Frediani, G.3    De Rossi, D.4
  • 8
    • 69549086750 scopus 로고    scopus 로고
    • Electroactive elastomeric haptic displays of organ motility and tissue compliance for medical training and surgical force feedback
    • Carpi, F., Frediani, G., De Rossi, D., "Electroactive elastomeric haptic displays of organ motility and tissue compliance for medical training and surgical force feedback", IEEE Transactions on Biomedical Engineering 56(9), 2327-2330 (2009).
    • (2009) IEEE Transactions on Biomedical Engineering , vol.56 , Issue.9 , pp. 2327-2330
    • Carpi, F.1    Frediani, G.2    De Rossi, D.3